文献速递主动脉疾病内脏/肾动脉与血管畸形

胸主动脉腔内修复术中有意覆盖腹腔干动脉的结局荟萃分析

Meta-analysis of outcomes after intentional coverage of celiac artery in thoracic endovascular aortic repair.
PubMed 文献 · J Vasc Surg · 2021-02-13

本荟萃分析纳入10项研究共171例患者,评估胸主动脉腔内修复术(TEVAR)中有意覆盖腹腔干动脉(CA)的临床结局。结果显示内脏缺血发生率为4.2%,脊髓缺血为3%,卒中为0.2%,内漏为24.1%,再干预为13.6%,30天死亡率为2.9%,1年死亡率为15.2%。结论认为对于开放手术高危的复杂胸主动脉病变患者,TEVAR中有意覆盖CA是安全可行的,可延长远端锚定区。

要点

  • TEVAR中有意覆盖腹腔干动脉的内脏缺血发生率较低(4.2%)。
  • 脊髓缺血发生率为3%,卒中为0.2%,30天死亡率为2.9%。
  • 内漏发生率24.1%,再干预率13.6%,需密切随访。

核心结论

  • 对于开放手术高危的复杂胸主动脉病变患者,TEVAR中有意覆盖腹腔干动脉是安全可行的选项。

研究设计与样本

  • 荟萃分析,检索MEDLINE、EMBASE和Cochrane Library数据库,纳入10项研究共171例患者。
  • 采用Moga评分和Newcastle-Ottawa量表评估方法学质量,使用随机效应模型合并估计值。

主要发现

  • 内脏缺血事件合并发生率为4.2%(95%CI 0.9-8.9%;I2=4.1%)。
  • 卒中发生率为0.2%(95%CI 0%-3.4%;I2=0%),脊髓缺血发生率为3%(95%CI 0.3%-7.4%;I2=6.1%)。
  • 随访期间内漏发生率为24.1%(95%CI 14.3%-35.1%;I2=20.0%),再干预率为13.6%(95%CI 4.4%-25.7%;I2=66.0%)。
  • 30天死亡率为2.9%(95%CI 0.3%-7.2%;I2=6.2%),1年死亡率为15.2%(95%CI 7.8%-23.9%;I2=0%)。

临床怎么用

  • 对于开放手术高危的复杂胸主动脉病变患者,可考虑TEVAR中有意覆盖腹腔干动脉以延长远端锚定区。
  • 术后需关注内脏缺血、脊髓缺血、卒中、内漏及再干预等结局,并进行密切随访。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The aim of the present study was to demonstrate the clinical outcomes of intentional coverage of the celiac artery (CA) during thoracic endovascular aneurysm repair (TEVAR). METHODS: The MEDLINE, EMBASE, and Cochrane Library databases were searched for studies reporting coverage of CA during TEVAR. The methodologic quality of the included studies was assessed using the Moga score and Newcastle-Ottawa scale. A random effects model was used to pool the estimates. A meta-analysis was performed with investigation of the following outcomes: visceral ischemia, spinal cord ischemia (SCI), stroke, endoleak, reintervention, 30-day mortality, and 1-year mortality. RESULTS: A total of 10 studies with 171 patients were included. The summary estimate rate of visceral ischemia events was 4.2% (95% confidence interval [CI], 0.9-8.9%; I2 = 4.1%). The incidence of stroke and SCI was 0.2% (95% CI, 0%-3.4%; I2 = 0%) and 3% (95% CI, 0.3%-7.4%; I2 = 6.1%). The rate of endoleak during the follow-up period was 24.1% (95% CI, 14.3%-35.1%; I2 = 20.0%). The reintervention rate was 13.6% (95% CI, 4.4%-25.7%; I2 = 66.0%). The 30-day and 1-year mortality were 2.9% (95% CI, 0.3%-7.2%; I2 = 6.2%) and 15.2% (95% CI, 7.8%-23.9%; I2 = 0%). CONCLUSIONS: Among the patients with complex thoracic aortic pathologies deemed at high risk for open reconstruction, TEVAR with intentional coverage of the CA is a safe and feasible option to extend the distal sealing zone with acceptable rates of visceral ischemia, SCI, type II endoleak from the CA, and 30-day mortality.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Han M, Wang J, Zhao J, et al. Meta-analysis of outcomes after intentional coverage of celiac artery in thoracic endovascular aortic repair. J Vasc Surg. 2021. PMID: 33592296. doi:10.1016/j.jvs.2021.01.053

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。