胸腹主动脉瘤范围对开窗/分支腔内修复结局的影响
本研究基于单中心前瞻性数据库,比较了299例开窗/分支腔内修复术中广泛型(范围1-3)与非广泛型(近肾、肾旁及范围4-5)胸腹主动脉瘤的结局。
要点
- 广泛型与非广泛型TAAA的F/BEVAR术后3年生存、靶动脉通畅率和再干预无显著差异。
- 广泛型TAAA的I/III型内漏和分支不稳定免除率显著更差。
核心结论
- 与开放手术不同,F/BEVAR治疗广泛型与非广泛型TAAA的结局相似。
研究设计与样本
- 单中心前瞻性数据库回顾性研究,纳入299例F/BEVAR手术,其中广泛型TAAA 87例(29%),非广泛型212例(71%)。
关键数值与推荐
- 广泛型TAAA定义为范围1-3,非广泛型包括近肾、肾旁及范围4-5。
- 分支不稳定定义为Ic或III型内漏、分支通畅性丧失或靶血管狭窄>50%。
临床怎么用
- 高容量中心可预期广泛型与非广泛型TAAA的F/BEVAR结局相当。
- 对广泛型TAAA应关注围术期轻瘫及远期内漏和分支不稳定风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The outcomes after open repair of thoracoabdominal aneurysms (TAAAs) have been definitively demonstrated to worsen as the TAAA extent increases. However, the effect of TAAA extent on fenestrated/branched endovascular aneurysm repair (F/BEVAR) outcomes is unclear. We investigated the differences in outcomes of F/BEVAR according to the TAAA extent. METHODS: We reviewed a single-institution, prospectively maintained database of all F/BEVAR procedures performed in an institutional review board-approved registry and/or physician-sponsored Food and Drug Administration investigational device exemption trial (trial no. G130210). The patients were stratified into two groups: group 1, extensive (extent 1-3) TAAAs; and group 2, nonextensive (juxtarenal, pararenal, and extent 4-5) TAAAs. The perioperative outcomes were compared using the χ2 test. Kaplan-Meier analysis of 3-year survival, target artery patency, reintervention, type I or III endoleak, and branch instability (type Ic or III endoleak, loss of branch patency, target vessel stenosis >50%) was performed. Cox proportional hazards modeling was used to assess the independent effect of extensive TAAA on 1-year mortality. RESULTS: During the study period, 299 F/BEVAR procedures were performed for 87 extensive TAAAs (29%) and 212 nonextensive TAAAs (71%). Most repairs had used company-manufactured, custom-made devices (n = 241; 81%). Between the two groups, no perioperative differences were observed in myocardial infarction, stroke, acute kidney injury, dialysis, target artery occlusion, access site complication, or type I or III endoleak (P > .05 for all). The incidence of perioperative paraparesis was greater in the extensive TAAA group (8.1% vs 0.5%; P = .001). However, the incidence of long-term paralysis was equivalent (2.3% vs 0.5%; P = .20), with nearly all patients with paraparesis regaining ambulatory function. On Kaplan-Meier analysis, no differences in survival, target artery patency, or freedom from reintervention were observed at 3 years (P > .05 for all). Freedom from type I or III endoleak (P < .01) and freedom from branch instability (P < .01) were significantly worse in the extensive TAAA group. Cox proportional hazards modeling demonstrated that F/BEVAR for extensive TAAA was not associated with 1-year mortality (hazard ratio, 1.71; 95% confidence interval, 0.91-3.52; P = .13). CONCLUSIONS: Unlike open TAAA repair, the F/BEVAR outcomes were similar for extensive and nonextensive TAAAs. The differences in perioperative paraparesis, branch instability, and type I or III endoleak likely resulted from the increasing length of aortic coverage and number of target arteries involved. These findings suggest that high-volume centers performing F/BEVAR should expect comparable outcomes for extensive and nonextensive TAAA repair.
引用
- Diamond KR, Simons JP, Crawford AS, et al. Effect of thoracoabdominal aortic aneurysm extent on outcomes in patients undergoing fenestrated/branched endovascular aneurysm repair. J Vasc Surg. 2021. PMID: 33617981. doi:10.1016/j.jvs.2021.01.062
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。