单中心回顾性分析57例亚急性及慢性主动脉夹层患者,使用定制Candy-Plug(CP I至CP III)封堵远端假腔。技术成功100%,临床成功95%,早期完全假腔闭塞88%,随访44例中主动脉重塑77%,新旧设计结局相似。

要点

  • 定制Candy-Plug封堵远端假腔技术成功率高,并发症和死亡率低。
  • 早期完全假腔闭塞率达88%,随访中 thoracic aortic remodeling 达77%。
  • CP I与CP II/III设计在临床成功、假腔闭塞及重塑方面结局相似。

核心结论

  • 定制Candy-Plug装置封堵主动脉夹层远端假腔技术可行,死亡率和并发症率低,主动脉重塑率高。
  • 原始设计CP I与带自闭合中央袖套的新设计CP II/III显示出相似的优异结局。

研究设计与样本

  • 回顾性单中心分析,纳入2013年10月至2019年9月连续接受定制Candy-Plug封堵远端假腔的亚急性及慢性主动脉夹层患者。
  • 共57例患者,其中34例使用CP I(29例男性,平均年龄62±10岁),23例使用CP II/III(16例男性,平均年龄59±17岁)。

主要发现

  • 技术成功57例(100%),临床成功54例(95%);CP I组33例(97%) vs CP II/III组21例(91%),p=0.116。
  • 平均住院时间10±8天(CP I组9±5天 vs CP II/III组13±9天,p=0.102)。
  • 30天CTA证实所有患者CP均放置于预期水平;早期完全假腔闭塞50例(88%),CP I组30例(88%) vs CP II/III组20例(87%),p=0.894。
  • 随访CTA可用44例(77%);CP I组30/34例(88%),平均随访29±17个月;CP II/III组14/23例(61%),平均随访14±5个月。
  • 主动脉重塑34/44例(77%);CP I组25/30例(83%) vs CP II/III组9/14例(64%),p=0.197;动脉瘤尺寸稳定9/44例(20%),CP I组5/30例(17%) vs CP II/III组4/14例(29%),p=0.741;动脉瘤增大1/44例(2%),该例在CP II/III组。

临床怎么用

  • 对于亚急性和慢性主动脉夹层伴远端假腔需封堵的患者,可考虑使用定制Candy-Plug装置。
  • CP I与CP II/III设计均可选择,两者在技术成功、假腔闭塞及主动脉重塑方面结局相似。

局限性

  • 回顾性单中心研究,样本量有限(57例),随访CTA仅44例(77%)可用。
  • CP II/III组随访时间较短(平均14±5个月 vs CP I组29±17个月),可能影响结局比较。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To report a single-center experience with the use of a custom-made Candy-Plug (CP) for distal false-lumen (FL) occlusion in subacute and chronic aortic dissection (AD). MATERIALS AND METHODS: A retrospective single-center analysis was conducted on consecutive patients with subacute and chronic AD who were treated with a custom-made CP for distal FL occlusion using 3 design generations (CP I to CP III) from October 2013 to September 2019. RESULTS: A custom-made CP was used in 57 patients. Of these, 34 patients (29 males, mean age 62±10 years) were treated with a CP I vs 23 patients (16 males, mean age 59±17 years) with CP II/III. Technical success was achieved in 57 (100%) patients. Clinical success was achieved in 54 (95%) patients; 33 (97%) in CP I group vs 21 (91%) patients in CP II/III group, p=0.116. The mean hospital stay was 10±8 days (9±5 days in CP I group vs 13±9 days in CP II/III, p=0.102). The 30-day computed tomography angiography (CTA) confirmed successful CP placement at the intended level in all patients within both groups. Early complete FL occlusion was achieved in 50 (88%) patients; 30 (88%) patients in CP I group vs 20 (87%) in CP II/III group, p=0.894. Follow up CTA was available in 44 (77%) patients. Of these; 30/34 (88%) patients in CP I group with mean follow-up 29±17 months) vs. 14/23 (61%) patients with mean follow-up 14±5 months in CP II/III group. Thoracic aortic remodeling was achieved in 34/44 (77%) patients; 25/30 (83%) patients in CP I group vs 9/14 (64%) patients in CP II/III group, p=0.197. The aneurysm size remained stable in 9/44 (20%) patients; 5/30 (17%) patients in CP I group vs 4/14 (29%) patients in CP II/III group, p=0.741. The thoracic aneurysm increased size was seen in 1/44 (2%) patient. This patient was in CPII/III group. CONCLUSION: CP technique using custom-made devices is technically feasible with a low mortality and morbidity, and a high rate of aortic remodeling. Both, the original design (CP I) and newer designs with a self-closing central sleeve (CP II and CP III) showed similar excellent outcomes.