文献速递内脏/肾动脉与血管畸形

定义肠系膜上动脉支架内再狭窄的双功能超声标准

Defining Duplex Ultrasound Criteria for In-Stent Restenosis of the Superior Mesenteric Artery.
PubMed 文献 · Ann Vasc Surg · 2021-01-27

本研究通过回顾性分析109例肠系膜上动脉支架患者,将支架内峰值收缩速度(PSV)与CTA测量的狭窄百分比相关,旨在定义预测≥70%支架内再狭窄的超声速度标准。结果显示PSV 300 cm/s预测≥70%狭窄的敏感性为100%、特异性80%,PSV 400 cm/s时敏感性63%、特异性90%。结论认为PSV 400 cm/s可作为诊断肠系膜上动脉支架内再狭窄的阈值。

要点

  • PSV 300 cm/s预测≥70%支架内再狭窄敏感性100%、特异性80%。
  • PSV 400 cm/s预测≥70%再狭窄敏感性63%、特异性90%。
  • PSV 450 cm/s特异性100%、敏感性50%。

核心结论

  • 肠系膜双功能超声PSV 400 cm/s可预测≥70%支架内再狭窄且敏感性较高,应考虑作为诊断阈值。

主要发现

  • PSV 300 cm/s预测≥70%支架内狭窄的敏感性100%、特异性80%。
  • PSV 400 cm/s预测≥70%支架内狭窄的敏感性63%、特异性90%。
  • PSV 450 cm/s预测≥70%支架内狭窄的敏感性50%、特异性100%。
  • 一例监测超声PSV 441 cm/s的患者死于急性-on-慢性肠系膜缺血并发症。

关键数值与推荐

  • PSV 300 cm/s:敏感性100%、特异性80%预测≥70%支架内再狭窄。
  • PSV 400 cm/s:敏感性63%、特异性90%预测≥70%支架内再狭窄。
  • PSV 450 cm/s:敏感性50%、特异性100%预测≥70%支架内再狭窄。

临床怎么用

  • 对肠系膜上动脉支架术后患者,监测超声PSV≥400 cm/s时应警惕≥70%支架内再狭窄并进一步评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study sought to define duplex ultrasound (DUS) velocity criteria predicting ≥70% stenosis in superior mesenteric artery (SMA) stents by correlating in-stent peak systolic velocity (PSV) with computed tomographic angiography (CTA) measurements of percent stenosis. METHODS: A retrospective review of 109 patients undergoing SMA stenting between 2003 and 2018 was conducted at a single institution. Thirty-seven surveillance duplex ultrasound studies were found to have a CTA performed within 30 days of study completion. Bare metal (n = 20) and covered stents (n = 17) were included. Velocities were paired to in-stent restenosis (ISR) measured by mean vessel diameter reduction on SMA centerline reconstructions from CTA. Receiver operating characteristic (ROC) curves was generated and logistic regression models for ≥70% ISR probability were used to define velocity criteria in the stented SMA. RESULTS: At a PSV of 300 cm/sec, the sensitivity is 100% and specificity 80% for a ≥70% in-stent SMA stenosis. At a PSV of 400 cm/sec, the sensitivity and positive predictive value (PPV) is 63% and the specificity and negative predictive value (NPV) is 90%. A PSV of 450 cm/sec was consistent with the highest specificity (100%) and PPV (100%) but lower sensitivity (50%) and NPV (87.9%). One patient with a PSV of 441 cm/sec on surveillance DUS died from complications of acute-on-chronic mesenteric ischemia. CONCLUSIONS: A PSV of 400 cm/sec on mesenteric DUS can predict ≥70% ISR with high sensitivity and should be considered as a diagnostic threshold for SMA in-stent restenosis.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Green J, Ryer E, Borden N, et al. Defining Duplex Ultrasound Criteria for In-Stent Restenosis of the Superior Mesenteric Artery. Ann Vasc Surg. 2021. PMID: 33508454. doi:10.1016/j.avsg.2020.12.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。