文献速递主动脉疾病

吻合环技术预防腹主动脉瘤开放术后近端吻合口漏

"Ring on Anastomosis" for Avoidance of Acute Proximal Anastomotic Leak after Open Surgical Repair of Abdominal Aortic Aneurysm.
PubMed 文献 · Ann Vasc Surg · 2021-01-01

吻合环组围手术期死亡和腹膜后血肿均低于传统组,手术时间和术中失血量无显著差异,随访18个月无近端吻合口狭窄。

要点

  • 吻合环技术可降低腹主动脉瘤开放术后近端吻合口漏相关并发症。
  • 吻合环组围手术期死亡和腹膜后血肿发生率均显著低于传统组。
  • 该技术不增加手术时间和术中失血量,且随访无吻合口狭窄。

核心结论

  • 吻合环技术作为传统开放手术的技术改进,可加固主动脉移植物吻合口,减少吻合口漏及围手术期死亡,且不增加时间和费用成本。

主要发现

  • 传统组死亡2例(2/54,3.7%),吻合环组无死亡(P=0.047)。
  • 传统组腹膜后血肿3例,吻合环组无血肿(P=0.027)。
  • 手术时间传统组(205.5±6.535)分钟 vs 吻合环组(195.6±6.034)分钟,P>0.05。
  • 术中失血量传统组(756±98.22)ml vs 吻合环组(673.1±98.93)ml,P>0.05。
  • 平均随访18个月,无近端吻合口狭窄报告。

关键数值与推荐

  • 吻合环制备方法:从移植物上剪取2 cm圆形环。
  • 围手术期死亡:传统组2/54(3.7%),吻合环组0例,P=0.047。
  • 腹膜后血肿:传统组3例,吻合环组0例,P=0.027。
  • 手术时间和术中失血量两组差异无统计学意义(P>0.05)。

临床怎么用

  • 在腹主动脉瘤开放手术中,可采用吻合环技术加固近端吻合口,以降低吻合口漏相关并发症风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Acute proximal anastomotic leak is among severe complications after open surgical repair (OSR) of abdominal aortic aneurysm. We have proposed an approach of "ring on anastomosis" (ROA) as a technical improvement of conventional OSR to reinforce proximal anastomotic section. METHODS: One hundred and nineteen abdominal aortic aneurysm patients admitted to Xiangya Hospital, Central South University were enrolled. Patients were randomly divided into conventional group (n = 54) and ROA group (n = 65). The ring is prepared by cutting out a 2-cm circle from the graft. Operative time, intraoperative blood loss, perioperative mortality, and retroperitoneal hematoma were recorded. Poisson distribution analysis was used between two groups. All methods were carried out in accordance with Declaration of Helsinki. RESULTS: No obvious difference in operative time or intraoperative blood loss was identified [(205.5 ± 6.535) versus (195.6 ± 6.034) minutes, P > 0.05; (756 ± 98.22) versus (673.1 ± 98.93) ml, P > 0.05, respectively]. Two patients in conventional group (2/54, 3.7%) died while no dead case was reported in ROA group (P = 0.047). Three cases in conventional group experienced retroperitoneal hematoma while none was witnessed in ROA group (P = 0.027). An average of 18 months of follow-up was obtained in all patients, and no proximal anastomotic stenosis was reported. CONCLUSIONS: As a technical improvement of conventional OSR, ROA reinforces aorta graft anastomotic section and diminishes anastomotic leak as well as perioperative death without extra cost of time and money.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Wang L, Pan B, Wang W, et al. "Ring on Anastomosis" for Avoidance of Acute Proximal Anastomotic Leak after Open Surgical Repair of Abdominal Aortic Aneurysm. Ann Vasc Surg. 2021. PMID: 33388411. doi:10.1016/j.avsg.2020.11.041

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。