静息间期切片选择性磁共振血管成像用于腹主动脉瘤治疗规划
本研究回顾性比较了30例肾下腹主动脉瘤患者QISS-MRA与CTA在15个血管节段管径和长度测量上的一致性。结果显示两种方法在所有15条血管测量上无显著差异,QISS-MRA虽不能提供钙化信息且仅30例中25例显示腔内血栓,但足以支持开放手术或EVAR决策,有望用于肾功能受损患者的EVAR规划。
要点
- QISS-MRA与CTA在15个血管节段的管径和长度测量上无显著差异。
- QISS-MRA无需辐射和对比剂,适用于肾功能受损的AAA患者术前评估。
- QISS-MRA对钙化和腔内血栓的显示有限,但足以支持OR或EVAR决策。
核心结论
- QISS-MRA是一种无辐射、无对比剂的AAA术前诊断方法,能准确测量血管管径和长度,潜在适用于肾功能受损患者的EVAR规划。
研究设计与样本
- 回顾性研究纳入30例已知肾下腹主动脉瘤且同时接受QISS-MR和CTA的患者,经当地研究伦理委员会批准。
- 两名观察者分析每个数据集,评估图像质量并测量15个血管节段的管腔直径和长度。
主要发现
- 两名观察者的诊断评分高度一致。
- CTA与QISS-MRA在所有15条测量血管上无显著差异。
- QISS-MRA缺乏钙化信息,且30例中仅25例显示腔内血栓。
- 两种成像方式均能支持实施开放手术或EVAR的决策。
临床怎么用
- QISS-MRA可作为无辐射、无对比剂的AAA术前成像选择,尤其适用于肾功能受损患者。
- 尽管QISS-MRA对钙化和血栓显示有限,其管径和长度测量准确性支持EVAR规划。
局限性
- 回顾性研究设计。
- 样本量为30例。
- QISS-MRA不提供钙化的确切信息,且仅部分患者(30例中25例)可见腔内血栓。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Diagnostic imaging of Abdominal aortic aneurysm (AAA) almost exclusively employs CT angiography (CTA) involving X-ray exposure and contrast medium that may harm some patients. Quiescent-Interval Slice Selective MR (QISS-MR) depicts vascular anatomy without radiation or contrast medium. The diagnostic quality of QISS-MRA and CTA were compared in regard to length and diameter measurements in AAA patients. Suitability of QISS-MRA for AAA treatment planning was evaluated. MATERIALS AND METHODS: The details of 30 patients with AAA who received both a QISS-MR and CTA for a known infrarenal AAA were obtained retrospectively that was approved by the local research ethics board. Two observers analyzed each dataset in terms of image quality and determined lumen diameter and length of 15 vessel segments. RESULTS: Highly accurate agreement between the diagnostic scores from the two observers was achieved. There was no significant difference between CTA and QISS-MRA for all 15 measured vessels. Although information on calcification was lacking and intraluminal thrombus was visualized in only 25 patients out of 30 patients, a founded decision to carry out OR or EVAR was possible with both imaging modalities. CONCLUSION: QISS-MRA presents a radiation and contrast free method for preoperative diagnostic AAA imaging. While QISS-MRA does not deliver exact information regarding calcification and thrombus formation, it does accurately allow measurement of vessel diameter and length. Therefore, it is potentially useful for EVAR planning in selected patients with impaired renal function.
引用
- Kazemtash M, Harth M, Derwich W, et al. Quiescent-Interval Slice Selective Magnetic Resonance Angiography for Abdominal Aortic Aneurysm Treatment Planning. J Endovasc Ther. 2021. PMID: 33478349. doi:10.1177/1526602821989341
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。