文献速递血液透析通路

术前指肱指数异常与动静脉瘘2年通畅率降低相关

Abnormal preoperative digital brachial index is associated with lower 2-year arteriovenous fistula access patency.
PubMed 文献 · J Vasc Surg · 2021-01-05

单中心回顾性研究纳入163例首次建立动静脉瘘的严重慢性肾脏病患者,术前用指体积描记法测量双侧指肱指数(DBI)。DBI异常(<80%或≥100%)者2年一期通畅率低于正常DBI者,校正后DBI异常增加一期通畅失败风险,低DBI还降低二期通畅率。

要点

  • 术前DBI异常(<80%或≥100%)与AVF 2年一期通畅率降低独立相关。
  • 低DBI(<80%)还增加二期通畅失败风险。
  • 流出静脉直径未决定AVF通畅率。

核心结论

  • 术前DBI异常患者AVF 2年通畅率低于DBI正常患者。
  • 指体积描记法测量DBI可能用于严重慢性肾脏病患者的术前咨询。

研究设计与样本

  • 单中心回顾性研究,2009年1月至2017年12月首次建立AVF前用指体积描记法测量双侧DBI。
  • 纳入163例患者(69例女性,年龄71±12岁),中位随访40周(范围0-104周,随访指数99%±1%)。

主要发现

  • 2年一期通畅率:低DBI组25%±11%,高DBI组28%±6%,正常DBI组49%±8%(P = .018)。
  • 校正年龄、性别、高血压、糖尿病、心血管疾病、吸烟及同侧中心静脉导管史后,低DBI(<80%)一期通畅失败风险HR 2.25(95%CI 1.13-4.48),高DBI(≥100%)HR 1.74(95%CI 1.06-2.85),P均< .030。
  • 低DBI组二期通畅失败风险HR 2.86(95%CI 1.08-7.59,P = .035)。
  • 流出静脉直径未决定通路通畅率。

关键数值与推荐

  • DBI 80%-99%为正常,<80%为低,≥100%为高;异常定义为低或高。
  • 分析采用与AVF同侧的DBI值。

临床怎么用

  • 对严重慢性肾脏病拟建AVF患者,术前可考虑指体积描记法测量DBI以辅助咨询。
  • DBI异常(<80%或≥100%)提示AVF通畅率可能较低。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The aim of the present study was to assess whether a single measurement of the digital brachial index (DBI; systolic finger pressure/systemic pressure ratio), reflecting the arm's circulation, was associated with access patency in patients with severe chronic kidney disease scheduled for arteriovenous fistula (AVF) creation. METHODS: A bilateral DBI was obtained using digital plethysmography just before construction of the patient's first AVF from January 2009 to December 2017 at one center. A DBI of 80% to 99% was considered normal, and a DBI of <80% (low) or DBI of ≥100% (high) were considered abnormal. DBI values ipsilateral to the AVF were used for analysis. The primary and secondary access patency rates were calculated using reported standards and compared using standard statistical techniques. RESULTS: Data sets of 163 patients were obtained (69 women; age, 71 ± 12 years). The median follow-up was 40 weeks (range, 0-104 weeks; follow-up index, 99% ± 1%). Patients with abnormal preoperative DBI values had lower 2-year primary patency rates (low DBI, 25% ± 11%; high DBI, 28% ± 6%; normal DBI, 49% ± 8%; P = .018). After correction for age, sex, hypertension, diabetes mellitus, cardiovascular disease, smoking status, and a history of ipsilateral central venous catheter use, an adjusted model demonstrated that abnormal DBI values conferred an increased risk of primary patency failure (low DBI [<80%]: hazard ratio [HR], 2.25; 95% confidence interval [CI], 1.13-4.48; high DBI [≥100%]: HR, 1.74; 95% CI, 1.06-2.85; P < .030 for both). Patients with a low preoperative DBI had also had diminished secondary patency (HR, 2.86; 95% CI, 1.08-7.59; P = .035). In contrast, the diameters of the outflow veins did not determine access patency. CONCLUSIONS: Patients with abnormal DBI values before AVF construction for hemodialysis had lower 2-year access patency rates compared with patients with a normal DBI. Plethysmographic finger measurements might have a role in the preoperative counseling of patients with severe chronic kidney disease requiring an AVF.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Yadav R, Gerrickens MWM, Teijink JAW, et al. Abnormal preoperative digital brachial index is associated with lower 2-year arteriovenous fistula access patency. J Vasc Surg. 2021. PMID: 33359237. doi:10.1016/j.jvs.2020.12.075

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。