1470nm激光裸光纤与径向光纤治疗大隐静脉功能不全的短期结局相似
一项随机对照研究纳入86例原发性大隐静脉曲张患者,比较1470nm激光裸光纤与径向光纤行腔内激光消融的短期效果。两组在8小时和1周疼痛评分、静脉临床严重程度评分改善及1个月静脉闭合率方面均相似,径向光纤未显示短期优势。
要点
- 1470nm激光裸光纤与径向光纤治疗大隐静脉功能不全的短期疼痛和闭合率相似。
- 两组静脉临床严重程度评分均显著改善,裸光纤组略优但差异无统计学意义。
- 两种光纤在1个月时均实现100%的靶静脉闭合。
核心结论
- 1470nm激光裸光纤与径向光纤治疗大隐静脉功能不全的短期结局相似。
- 两种光纤均与1个月时静脉临床严重程度评分的显著改善相关。
研究设计与样本
- 随机对照研究,纳入86例原发性大隐静脉曲张患者,裸光纤组43例,径向光纤组43例,研究期为2019年1月至12月。
- 患者在术后24小时、1周和1个月接受临床评估和静脉多普勒超声检查。
主要发现
- 线性静脉内能量密度裸光纤组65.7 J/cm,径向光纤组65.2 J/cm,两组相似。
- 肿胀局部麻醉液用量裸光纤组627.4 mL,径向光纤组661.4 mL,两组相似。
- 术后8小时疼痛评分裸光纤组2.77,径向光纤组2.70,两组相似。
- 术后1周疼痛评分裸光纤组2.81,径向光纤组2.74,两组相似。
- 两组静脉临床严重程度评分均显著改善,裸光纤组略优但差异无统计学意义;1个月时两组靶静脉闭合率均为100%。
临床怎么用
- 对于大隐静脉功能不全的腔内激光消融,1470nm激光裸光纤与径向光纤均可作为选择,短期疗效相当。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The common side effects of endovenous laser ablation (EVLA) are pain and discomfort in the treated leg. We compared the pain and outcomes after EVLA using a 1470-nm laser with bare tip or radial fibers in the treatment of incompetent great saphenous veins (GSVs). METHODS: A total of 86 patients with primary varicose veins of the GSV were randomized to treatment using a 1470-nm laser and bare fiber (BF; n = 43) or radial fiber (RF; n = 43) during a 12-month period from January to December 2019. Patients were assessed clinically and using venous Doppler ultrasonography at 24 hours, 1 week, and 1 month. The periprocedural parameters and short-term outcomes of pain after the procedure, improvement in the Venous Clinical Severity Score (VCSS), and vein occlusion at 1 month were compared and analyzed. RESULTS: The linear endovenous energy density (65.7 J/cm vs 65.2 J/cm), tumescent local anesthetic solution used (627.4 mL vs 661.4 mL), treated GSV length, and number of hook phlebectomies were similar in both groups. The pain score at 8 hours (2.77 vs 2.70) and 1 week (2.81 vs 2.74) were similar in the BF and RF groups, respectively. The improvement in the VCSS was significant in both groups and was slightly better in the BF group, although the difference was not statistically significant. Both fiber types had 100% efficacy in terms of closure of the treated vein at 1 month. CONCLUSIONS: EVLA using a 1470-nm laser with a BF had similar outcomes in the short term compared with a RF of the same wavelength. Both fibers were associated with significant improvement in the VCSS at 1 month.
引用
- Rajendran S, Nair HR. Endovenous laser ablation of incompetent great saphenous veins with 1470-nm laser using bare tip and radial fibers results in similar short-term outcomes. J Vasc Surg Venous Lymphat Disord. 2020. PMID: 33340731. doi:10.1016/j.jvsv.2020.12.069
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。