文献速递颈动脉与弓上血管

放射性颈内动脉狭窄支架术后再干预风险更高:单中心分析与系统综述

Higher Risk for Reintervention in Patients after Stenting for Radiation-Induced Internal Carotid Artery Stenosis: A Single-Center Analysis and Systematic Review.
PubMed 文献 · Ann Vasc Surg · 2020-12-26

单中心多站点病例对照研究比较放射性(RI)与动脉粥样硬化性(AS)颈内动脉狭窄的颈动脉支架(CAS)结局,RI组再干预率10.1%高于AS组1.4%,条件回归显示再干预风险更高(OR=7.1,95%CI 2.1-32.8,P=0.004),系统综述认为CAS是RI狭窄的良好替代方案但需谨慎选择患者。

要点

  • RI颈内动脉狭窄CAS后再干预率10.1%,显著高于AS组的1.4%。
  • 条件回归显示RI组再干预风险显著增高(OR=7.1,95%CI 2.1-32.8,P=0.004)。
  • RI狭窄CAS安全有效,但需密切监测再狭窄并谨慎选择患者。

核心结论

  • RI颈内动脉狭窄患者CAS后再狭窄率和再干预次数均高于AS患者。
  • CAS对RI颈内动脉狭窄安全有效,但需进一步数据降低再狭窄风险并密切监测。
  • 系统综述认为CAS是RI颈内动脉狭窄治疗的优良替代选择,但长期随访再狭窄风险增高需谨慎选择患者。

研究设计与样本

  • 单中心、多站点病例对照研究,纳入2000年1月至2019年12月CAS数据库中的RI颈内动脉狭窄支架病例。
  • RI组按年龄、性别和CAS年份与AS组以2:1随机匹配。
  • 采用条件逻辑回归模型估计RI组再干预的比值比,并进行系统综述评估RI狭窄CAS结局。

主要发现

  • RI组再干预率10.1%,AS组1.4%;14条血管发生再干预,原因为再狭窄12条、TIA/卒中2条。
  • 条件回归显示RI颈内动脉狭窄患者再干预风险更高(OR=7.1,95%CI 2.1-32.8;P=0.004)。
  • 平均随访33.7±36.9个月,各组间死亡率无差异(P=0.12)。
  • 放射性原因最常见为头颈部恶性肿瘤治疗109例(96.5%),平均放疗剂量58.9±15.6 Gy,放疗至CAS时间175.3±140.4个月。
  • 症状包括31例TIA、21例卒中(7例急性、14例亚急性)和17例一过性黑矇,急性卒中平均NIHSS评分8.7±11.2。

临床怎么用

  • 对RI颈内动脉狭窄行CAS后应密切监测再狭窄,因再干预风险显著高于AS患者。
  • CAS可作为RI颈内动脉狭窄的治疗选择,但需谨慎选择患者并加强长期随访。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study aimed to review short- and long-term outcomes of all carotid artery stenting (CAS) in patients with radiation-induced (RI) internal carotid artery (ICA) stenosis compared with patients with atherosclerotic stenosis (AS). METHODS: We performed a single-center, multisite case-control study of transfemoral carotid artery intervention in patients stented for RI or AS. Cases of stented RI carotid arteries were identified using a CAS database covering January 2000 to December 2019. These patients were randomly matched 2:1 with stented patients because of AS by age, sex, and year of CAS. A conditional logistic regression model was performed to estimate the odds of reintervention in the RI group. Finally, a systematic review was performed to assess the outcomes of RI stenosis treated with CAS. RESULTS: There were 120 CAS in 113 patients because of RI ICA stenosis. Eighty-nine patients (78.8%) were male, and 68 patients (60.2%) were symptomatic. The reasons for radiation included most commonly treatment for diverse malignancies of the head and neck in 109 patients (96.5%). The mean radiation dose was 58.9 ± 15.6 Gy, and the time from radiation to CAS was 175.3 ± 140.4 months. Symptoms included 31 transient ischemic attacks (TIAs), 21 strokes (7 acute and 14 subacute), and 17 amaurosis fugax. The mean National Institutes of Health Stroke Scale in acute strokes was 8.7 ± 11.2. In asymptomatic patients, the indication for CAS was high-grade stenosis determined by duplex ultrasound. All CAS were successfully completed. Reinterventions were more frequent in the RI ICA stenosis cohort compared with the AS cohort (10.1% vs. 1.4%). Reinterventions occurred in 14 vessels, and causes for reintervention were restenosis in 12 followed by TIA/stroke in two vessels. On conditional regression modeling, patients with RI ICA stenosis were at a higher risk for reintervention (odds ratio = 7.1, 95% confidence interval = 2.1-32.8; P = 0.004). The mean follow-up was 33.7 ± 36.9 months, and the mortality across groups was no different (P = 0.12). CONCLUSIONS: In our single-center, multisite cohort study, patients who underwent CAS for RI ICA stenosis experienced a higher rate of restenosis and a higher number of reinterventions compared with CAS for AS. Although CAS is safe and effective for this RI ICA stenosis cohort, further data are needed to reduce the risk of restenosis, and close patient surveillance is warranted. In our systematic review, CAS was considered an excellent alternative option for the treatment of patients with RI ICA stenosis. However, careful patient selection is warranted because of the increased risk of restenosis on long-term follow-up.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Erben Y, Franco-Mesa C, Miller D, et al. Higher Risk for Reintervention in Patients after Stenting for Radiation-Induced Internal Carotid Artery Stenosis: A Single-Center Analysis and Systematic Review. Ann Vasc Surg. 2020. PMID: 33373766. doi:10.1016/j.avsg.2020.11.027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。