要点

  • 医师改良支架移植物用于高危肾旁/胸腹主动脉瘤急诊治疗可行且安全
  • 3D打印技术可能改善复杂主动脉病变的急诊患者特异性器械构建

核心结论

  • 医师改良支架移植物用于不适合市售支架移植物的高危肾旁和胸腹主动脉瘤患者的急诊治疗是可行且安全的。
  • 3D打印技术可能改善复杂主动脉病变急诊患者特异性器械的构建并改善预后。

研究设计与样本

  • 连续纳入19例患者(17例男性;平均年龄70±9岁),于2015年至2019年接受医师改良支架移植物开窗腔内修复术。
  • 2018年引入3D打印主动脉模型用于规划医师改良支架移植物。
  • 终点为全因死亡率、任何内漏的免除、靶血管通畅性和再干预。

主要发现

  • 7例(36.8%)使用3D图像分析软件规划,12例(63.2%)使用3D打印主动脉模型规划。
  • 6例表现为包裹性主动脉破裂,13例因症状性主动脉瘤接受治疗;平均主动脉直径为72±10 mm。
  • 2例发生可逆性脊髓损伤;平均随访14.4个月(范围1-52个月),期间发生1例非动脉瘤相关死亡和2次成功再干预。

临床怎么用

  • 对于不适合市售支架移植物的高危肾旁或胸腹主动脉瘤患者,可考虑使用医师改良支架移植物行急诊开窗腔内修复。
  • 3D打印主动脉模型可能有助于急诊规划患者特异性开窗位置。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The aim was to describe the outcomes of high risk patients with symptomatic or contained rupture of pararenal (PRAs) and thoraco-abdominal aortic aneurysms (TAAAs) with anatomy unsuitable for commercially available stent grafts who underwent fenestrated endovascular aneurysm repair (FEVAR) using physician modified stent grafts (PMSGs) planned with 3D image analysis software (3DIMAS), and 3D printed aortic models (3DAMs). METHODS: Nineteen consecutive patients (17 male; mean age, 70 ± 9 years) underwent PMSG-FEVAR between 2015 and 2019. 3DAMs to plan the PMSGs were introduced in 2018. End points were all cause mortality, freedom from any endoleak, target vessel patency, and re-intervention. RESULTS: Seven patients (36.8%) were treated with PMSGs using 3DIMAS (three PRAs, three type IV, and one type III TAAAs), and 12 patients (63.2%) received PMSGs using 3DAMs (five PRAs, seven type IV TAAAs). Six patients presented with contained aortic rupture and 13 patients were treated for symptomatic aortic aneurysm. Mean aortic diameter was 72 ± 10 mm. The choice of stent graft for fenestration was the Valiant Captivia Closed Web (Medtronic), except for one patient. Sixteen (84.2%) stent grafts were manufactured with four fenestrations. Technical success was 100%. Seventy-one renovisceral branch vessels were targeted with fenestrations. Mean length of hospital stay was 17.3 ± 10.4 days. Thirty day mortality was 0%. Two patients developed reversible spinal cord injury. Mean follow up was 14.4 months (range 1-52 months). During follow up one non-aneurysm related death occurred, and two successful re-interventions were performed: one to re-establish renal artery patency, and one to treat a type 1c endoleak. CONCLUSION: PMSGs for urgent treatment of pararenal and thoraco-abdominal aortic aneurysms in high risk patients unsuitable for commercially available stent grafts are feasible and safe. 3D printing technology may improve urgent construction of patient specific devices for treatment of complex aortic pathologies and improve outcomes.