开窗与分支腔内动脉瘤修复中桥接支架的系统综述
该系统综述纳入2014至2019年19项研究,共2796例接受开窗或分支腔内动脉瘤修复的复杂主动脉瘤患者,桥接目标血管9556条。高容量分析显示肾动脉桥接支架并发症率6%(95%CI 4-8)高于内脏动脉2%(95%CI 1-3),再干预率相近;球囊扩张与自膨式支架并发症率分别为3%和4%。
要点
- 肾动脉桥接支架并发症率6%高于内脏动脉2%,再干预率相近。
- 球囊扩张与自膨式支架并发症率分别为3%与4%,选择仍不明确。
- 详细数据报告一致性低,需规范桥接支架相关结局的报告。
核心结论
- 系统综述强调F/B-EVAR中桥接支架详细数据报告的一致性低。
- 肾动脉目标血管更易发生并发症,再干预率与内脏动脉相当。
- 对于分支腔内修复,球囊扩张支架优于自膨式支架的选择仍不确定。
研究设计与样本
- 系统综述遵循PRISMA指南和PICO模型,检索MEDLINE、EMBASE和Cochrane Library 2014至2019年文献。
- 纳入19项原始研究,共2796例复杂主动脉瘤行F/B-EVAR患者,桥接目标血管9556条。
- 由两名作者筛选文献(分歧时第三作者参与),并进行质量评估评分。
主要发现
- 桥接的目标血管中肾动脉4797条(50.2%),内脏动脉4174条(43.6%),未定义目标血管585条(6.1%)。
- 使用的桥接支架中球囊扩张支架占40.9%,自膨式支架占22.7%,未定义支架占36.3%。
- 高容量分析确认肾动脉并发症率6%(95%CI 4-8)高于内脏动脉2%(95%CI 1-3)。
- 再干预率肾动脉为3%(95%CI 2-4),内脏动脉为2%(95%CI 1-3)。
- 自膨式与球囊扩张支架并发症率分别为4%(95%CI 2-7)和3%(95%CI 2-5)。
临床怎么用
- 临床中应关注肾动脉桥接支架的并发症风险,其发生率高于内脏动脉。
- 选择球囊扩张或自膨式支架时需权衡并发症数据,目前证据尚不确定。
- 应推动规范报告桥接支架的详细数据以改善证据质量。
局限性
- 纳入研究存在异质性。
- 详细数据报告的一致性低。
- 部分支架类型和目标血管未定义。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Concern exists about durability of stent grafts used to bridge aortic grafts to visceral and renal arteries during fenestrated and branched endovascular aneurysm repair (F/B-EVAR). There are no guidelines regarding the ideal technique for joining target vessels (TVs). METHODS: We systematically reviewed data published from 2014 to 2019 using PRISMA guidelines and PICO models. Keywords were searched in MEDLINE, EMBASE, and Cochrane Library. All articles were screened by two authors (a third author in case of discrepancies). Only original articles regarding F/B-EVAR in complex aortic aneurysm, reporting the number and type of TVs mated, the onset of bridging stent complications, and reinterventions on TVs were included. Analysis included quality assessment scoring, types of stent grafts, and complications related to bridging stents. RESULTS: 19 studies were included with 2,796 patients and 9556 TV; 4,797 renal arteries (50.2%), 4,174 visceral arteries (43.6%), and undefined TV (n = 585; 6.1%) were bridged. Balloon-expandable stent-grafts (B-EXP) were used in 40.9% and self-expandable (S-EXP) in 22.7% and undefined stents in 36.3%. The included studies had quality assessment scores ranging between 11/15 and 15/15, with high grade of accordance on reporting general results, but a low grade of accordance on reporting detailed data. Despite study heterogeneity, high-volume analysis confirmed a higher rate of complication in renal arteries than visceral arteries, 6% (95% CI 4-8) vs. 2% (95% CI 1-3), respectively. The rate of reinterventions was similar, 3% (95% CI 2-4) and 2% (95% CI 1-3). S-EXP versus B-EXP stent complication was 4% (95% CI 2-7) vs. 3% (95% CI 2-5), respectively. CONCLUSIONS: This systematic review underlines the low grade of accordance in reporting detailed data of bridging stents in F/B-EVAR. Renal TVs were more prone to complications, with an equivalent reintervention rate to visceral TVs. As to B-EVAR, the choice of B-EXP over S-EXP is still uncertain.
引用
- Mezzetto L, Scorsone L, Silingardi R, et al. Bridging Stents in Fenestrated and Branched Endovascular Aneurysm Repair: A Systematic REVIEW. Ann Vasc Surg. 2021. PMID: 33359330. doi:10.1016/j.avsg.2020.10.052
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。