多普勒超声作为外周动脉疾病唯一的诊断检查
结果显示DUS在股腘段与术中造影一致性优于CT血管造影,基于DUS的手术方案准确率为86%。
要点
- DUS在髂、股、腘段的敏感性分别为100%、80%、100%,特异性分别为93.55%、95.45%、90.48%。
- DUS与术中造影的Kappa值在髂段0.587、股段0.799、腘段0.699。
- 基于DUS的手术方案在86%的病例中准确。
核心结论
- DUS对股腘区域动脉成像优于CT血管造影,可考虑作为下肢血运重建术前唯一的影像学检查。
主要发现
- DUS在髂、股、腘段的敏感性分别为100%(95%CI 83.3-100%)、80%(95%CI 50.21-100%)、100%(95%CI 96.43-100%)。
- DUS在髂、股、腘段的特异性分别为93.55%(95%CI 83.29-100%)、95.45%(95%CI 84.48-100%)、90.48%(95%CI 75.54-100%)。
- DUS阳性预测值在髂、股、腘段分别为60%(95%CI 7.06-100%)、88.9%(95%CI 62.8-100%)、87.5%(95%CI 68.17-100%),阴性预测值分别为100%(95%CI 98.28-100%)、91.3%(95%CI 77.61-100%)、100%(95%CI 97.37-100%)。
- DUS与术中造影的Kappa值:髂段0.587(P=0.000)、股段0.799(P=0.000)、腘段0.699(P=0.000);CT血管造影与术中造影的Kappa值:髂段0.71(P=0.0093)、股段0.566(P=0.006)、腘段0.5(P=0.028)。
- 基于DUS的手术方案在86%(n=44)的病例中准确。
临床怎么用
- 在下肢血运重建术前,可优先使用DUS进行动脉成像以规划手术,尤其在股腘区域。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The aim of this study was to analyze duplex ultrasound (DUS) and intraoperative angiography concordance for diagnosis of lower limb peripheral artery disease and its value for surgical planning. MATERIALS AND METHODS: This was a prospective, observational study, including patients who underwent revascularization of the lower limbs during 2018, diagnosed by DUS only or combined with preoperative computed tomography (CT) angiography. The concordance between preoperative DUS or CT angiography and the intraoperative angiography was studied using the Cohen kappa coefficient (k). The degree of agreement between the DUS-based surgical plan and the final surgical technique was also evaluated. RESULTS: Fifty-one patients were included, with mean age of 71.8 ± 11.96 years (46-94); 23 had chronic kidney disease (45%). In 17 patients (34%), preoperative CT angiography was also performed. DUS showed a sensitivity of 100% (95% confidence interval (CI) [83.3-100%]), 80% (95% CI [50.21-100%,]), and 100% (95% CI [96.43-100%]) at the iliac, femoral, and popliteal sector, respectively, and a specificity of 93.55% (95% CI [83.29-100%]), 95.45% (95% CI [84.48-100%]), and 90.48% (95% CI [75.54-100%]) at the iliac, femoral, and popliteal sector, respectively. The positive predictive value for DUS was 60% (95% CI [7.06-100%]), 88.9% (95% CI [62.8-100%]), and 87.5% (95% CI [68.17-100%]) for the iliac, femoral, and popliteal sectors, respectively, whereas the negative predictive value was 100% (95% CI [98.28-100%]), 91.3% (95% CI [77.61-100%]), and 100% (95% CI, [97.37-100%]). The concordance between DUS and intraoperative angiography showed a k index of 0.587 (P = 0.000) in the iliac sector, 0.799 in the femoral sector (P = 0.000), and 0.699 in the popliteal sector (P = 0.000). The concordance between CT angiography/intraoperative angiography had a k index of 0.71 in the iliac sector (P = 0.0093), 0.566 in the femoral sector (P = 0.006), and 0.5 in the popliteal sector (P = 0.028). DUS-based surgical plan was accurate in 86% of cases (n = 44). CONCLUSIONS: Our experience suggests that DUS arterial mapping of the femoral and popliteal areas is better than CT angiography and can be considered as a unique preoperative imaging test during the surgical planning in patients undergoing a lower limb revascularization procedure.
引用
- García-Rivera E, Cenizo-Revuelta N, Ibáñez-Maraña MA, et al. Doppler Ultrasound as a Unique Diagnosis Test in Peripheral Arterial Disease. Ann Vasc Surg. 2020. PMID: 33249132. doi:10.1016/j.avsg.2020.10.027
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。