文献速递主动脉疾病

Onyx与弹簧圈栓塞治疗II型内漏的对比研究

Onyx versus coil embolization for the treatment of type II endoleaks.
PubMed 文献 · J Vasc Surg · 2020-11-27

该回顾性研究比较了Onyx与弹簧圈栓塞治疗EVAR后因瘤囊增大需处理的II型内漏的效果,共纳入58例患者77次手术。Onyx组再干预率显著更低(19% vs 55%,P<.01),临床成功率更高(48% vs 32%,P=.04),但两组移植物切除率无显著差异。

要点

  • Onyx栓塞后需进一步再干预的比例显著低于弹簧圈(19% vs 55%,P<.01)。
  • Onyx组临床成功率48%,弹簧圈组32%(P=.04)。
  • 无论何种技术,栓塞后均需密切随访,因再干预率高且存在瘤囊破裂风险。

核心结论

  • 对EVAR后因瘤囊增大需处理的II型内漏,Onyx栓塞较弹簧圈栓塞更少需要进一步再干预。
  • 弹簧圈栓塞组有需要移植物切除的趋势,但两组间无统计学显著差异(P=.33)。
  • 无论采用何种栓塞技术,尝试栓塞II型内漏后均需 diligent 随访,因再干预率高且存在瘤囊破裂可能。

研究设计与样本

  • 回顾性分析前瞻性收集的血管外科数据库数据,纳入2005至2018年因EVAR后瘤囊增大行II型内漏栓塞的患者。
  • 共58例患者接受77次栓塞手术,Onyx组27例(37次手术),弹簧圈组31例(40次手术)。
  • 采用单变量统计比较两组。

主要发现

  • 栓塞时平均动脉瘤直径Onyx组为77.9±15.1 mm,弹簧圈组为73.4±11.9 mm。
  • Onyx组平均随访57个月,弹簧圈组74个月。
  • Onyx组27例中2例(7.4%)需移植物切除,弹簧圈组31例中5例(16.1%)需移植物切除(P=.33)。
  • 按患者分析,弹簧圈组需进一步再干预率显著高于Onyx组(55% vs 19%,P<.01)。
  • 临床成功Onyx组13例(48%),弹簧圈组10例(32%)(P=.04);两组各有2例在尝试栓塞后出现瘤囊二次破裂。

临床怎么用

  • 对于EVAR后因瘤囊增大需处理的II型内漏,可优先考虑Onyx栓塞以减少再干预需求。
  • 无论采用Onyx还是弹簧圈,栓塞后均应严格影像随访以监测再干预指征和瘤囊破裂风险。

局限性

  • 回顾性设计,样本量较小(58例患者,77次手术),可能影响统计效能。
  • 两组动脉瘤大小和随访时间存在差异,Onyx组瘤囊更大、随访更短。
  • 未报告多变量校正结果,混杂因素可能影响比较。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Little evidence is available supporting the optimal treatment of type II endoleaks associated with aortic sac growth. Previous studies have lacked comparisons between treatment methods and long-term follow-up. The purpose of the present study was to review our center's experience with the treatment of type II endoleaks comparing Onyx (a liquid embolization agent consisting of ethylene vinyl alcohol; Medtronic, Minneapolis, Minn) embolization and coil embolization. METHODS: A retrospective review of prospectively collected data from a vascular surgery database was performed to identify all patients who had undergone embolization of a type II endoleak for aortic sac growth after endovascular aneurysm repair from 2005 to 2018. The Onyx and coil embolization groups were compared using univariate statistics. RESULTS: A total of 58 patients had undergone 77 embolization procedures for type II endoleaks with either Onyx (27 patients; 37 procedures) or coils (31 patients; 40 procedures). The average aneurysm size at embolization was larger in the Onyx group (77.9 ± 15.1 mm) compared with coil embolization (73.4 ± 11.9 mm). The mean follow-up was 57 months for the Onyx group and 74 months for the coil embolization group. Of the 27 patients who had undergone Onyx embolization, 2 (7.4%) had required graft explantation compared with 5 of the 31 patients (16.1%) who had undergone coil embolization (P = .33). The results of the per-patient analysis showed that the coil embolization group had a significantly greater rate of the need for further reintervention compared with the Onyx group (55% vs 19%; P < .01). Clinical success was observed in 13 patients (48%) in the Onyx embolization group compared with 10 patients (32%) in the coil embolization group (P = .04). Two patients in each group had presented with secondary rupture of the aneurysm sac after attempted embolization. CONCLUSIONS: Type II endoleaks associated with sac growth treated with Onyx were less likely to require further reinterventions than were those treated with coil embolization. A trend was found toward a greater need for endovascular aneurysm repair explant after coil embolization. With a high rate of further reintervention and potential for sac rupture, diligent follow-up is required after attempted type II embolization, regardless of the technique used.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Scallan O, Kribs S, Power AH, et al. Onyx versus coil embolization for the treatment of type II endoleaks. J Vasc Surg. 2020. PMID: 33249208. doi:10.1016/j.jvs.2020.10.069

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。