文献速递主动脉疾病外周动脉疾病

超低剖面内移植物腹主动脉瘤腔内修复的早中期结局:Triveneto Incraft注册研究

Early and midterm outcomes of endovascular aneurysm repair with an ultra-low-profile endograft from the Triveneto Incraft Registry.
PubMed 文献 · J Vasc Surg · 2020-11-25

该研究基于意大利Triveneto地区10个血管外科中心的多中心前瞻性注册数据,分析209例择期使用Incraft超低剖面内移植物行腹主动脉瘤腔内修复的患者。技术成功率达99.5%,30天主要并发症率1.5%,无30天死亡;平均随访18.5个月,总死亡率9.5%,均与动脉瘤无关,免于再干预率92.1%。

要点

  • Incraft超低剖面内移植物在复杂解剖患者中技术成功率高、早期并发症少。
  • 同时存在两项及以上复杂髂动脉因素与再干预风险升高独立相关。
  • 尽管存在挑战性解剖,该装置的再干预率仍保持在较低水平。

核心结论

  • Incraft内移植物在复杂解剖患者中行EVAR的早中期结局良好,但两项及以上复杂髂动脉因素并存仍是EVAR成功的挑战。

研究设计与样本

  • Triveneto Incraft注册研究为意大利Triveneto地区10个血管外科中心的独立多中心前瞻性队列注册。
  • 纳入2014年9月至2019年6月择期使用Incraft内移植物行EVAR的患者209例,平均年龄76.9±7.7岁,SVS合并症评分0.97±0.52。

主要发现

  • 技术成功率99.5%,早期主要并发症率1.5%(1例肢体闭塞、1例髂支狭窄、1例III型内漏),无30天死亡。
  • 平均随访18.5±13.2个月,总死亡率9.5%(18例),均与动脉瘤无关,免于再干预率92.1%。
  • 再干预原因包括II型内漏栓塞6例(3.2%)、IA型内漏1例(0.5%)、髂支闭塞4例(2.1%)、限流性髂外动脉夹层1例(0.5%)。
  • 该复杂髂动脉亚组(67例)的粗再干预率较低(4例,6%)。

关键数值与推荐

  • 复杂解剖因素定义:主动脉颈角α<135°(31例,14.8%)、锥形颈(17例,8.2%)、髂动脉迂曲指数τ>1.5(102例,48.8%)、髂动脉钙化>50%(106例,50.7%)、髂外动脉<6 mm(45例,21.5%)。

临床怎么用

  • Incraft超低剖面内移植物可用于复杂解剖(包括复杂髂动脉)患者的EVAR,早中期结果良好。
  • 对于同时存在两项及以上复杂髂动脉因素的患者,应加强术后随访监测再干预风险。

局限性

  • 本研究为观察性注册研究,随访时间有限(平均18.5个月),可能影响中期结局的评估。
  • 样本量及事件数较少,尤其是再干预事件,可能限制统计效能。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: We evaluated the early and midterm outcomes of the Incraft (Cordis Corp, Bridgewater, NJ) ultra-low-profile endograft by analyzing data from the Triveneto Incraft Registry (TIR). METHODS: TIR is an independent multicenter cohort registry of 10 vascular surgery units in the Triveneto area (Northeast Italy). A prospective analysis of patients electively treated with Incraft from September 2014 to June 2019 was performed. The main outcomes were technical success, major 30-day complications, 30-day aneurysm-related death, freedom from reintervention, and mortality rate during follow-up and were analyzed using Kaplan-Meier curves. Univariable Cox regression was used to evaluate the associations between anatomic complexity factors and reintervention. RESULTS: During the study period, 209 patients were included in the registry. Their mean age was 76.9 ± 7.7 years and the Society for Vascular Surgery comorbidity score was 0.97 ± 0.52. Most patients (n = 181; 86.6%) had presented with at least one complex anatomic factor: aortic neck angle α <135° in 31 patients (14.8%), conic neck in 17 patients (8.2%), iliac tortuosity index τ >1.5 in 102 (48.8%), iliac artery calcification >50% in 106 (50.7%), and external iliac artery <6 mm in 45 (21.5%). The concurrent presence of two or more complex iliac anatomic factors was present in 67 patients (32.1%). The technical success rate was 99.5%, and the early major complication rate was 1.5% (one limb occlusion, one iliac branch stenosis, one type III endoleak [EL]). No 30-day mortality was recorded. The mean follow-up period was 18.5 ± 13.2 months. The overall mortality was 9.5% (n = 18), none related to the aneurysm. The freedom from reintervention rate was 92.1%. Of these patients, six (3.2%) had been treated for type II EL embolization, one (0.5%) for type IA EL, four (2.1%) for iliac branch occlusion, and one (0.5%) for flow-limiting external iliac artery dissection. None of the single anatomic factors analyzed were predictive of reintervention. However, the association of two or more complex iliac anatomic factors was predictive of related reintervention (hazard ratio, 7.25; P = .014). The crude reintervention rate in this complex subgroup of patients was low (4 of 67; 6%). CONCLUSIONS: Data from the TIR have demonstrated excellent early and midterm outcomes of endovascular aneurysm repair using the Incraft stent graft in patients with complex anatomy. The concurrent presence of two or more complex iliac anatomic factors still represent an issue for endovascular aneurysm repair success. However, the technical characteristics of this device resulted in low intervention rates, even for patients with these challenging issues.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Zavatta M, Squizzato F, Balestriero G, et al. Early and midterm outcomes of endovascular aneurysm repair with an ultra-low-profile endograft from the Triveneto Incraft Registry. J Vasc Surg. 2020. PMID: 33248119. doi:10.1016/j.jvs.2020.09.044

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。