文献速递颈动脉与弓上血管

颈动脉支架开放与闭合单元设计 Outcomes 比较:VQI 分析

Comparison of open- and closed-cell stent design outcomes after carotid artery stenting in the Vascular Quality Initiative.
PubMed 文献 · J Vasc Surg · 2020-10-17

基于 VQI 2016–2018 年 2671 例颈动脉支架术,闭合与开放单元支架在院内死亡、卒中及卒中/死亡无显著差异;但病变位于颈动脉分叉时,闭合单元支架院内卒中/死亡 odds 为 5.5 倍,1 年同侧卒中/死亡 HR 为 6.7。

要点

  • 总体院内卒中/死亡在闭合与开放单元支架间无差异(OR 1.08,95%CI 0.68–1.74)。
  • 分叉病变用闭合单元支架院内卒中/死亡 odds 显著升高(OR 5.5,95%CI 1.3–22.2)。
  • ICA 病变两种支架院内卒中/死亡无差异(OR 0.87,95%CI 0.51–1.45)。

核心结论

  • 闭合单元支架用于颈动脉分叉病变时院内卒中/死亡 odds 增加,可能与其在迂曲、直径不匹配的分叉解剖中顺应性较低有关。
  • 在 ICA 病变中未观察到闭合与开放单元支架的院内卒中/死亡差异。
  • 1 年随访仅 19% 患者有数据,分叉病变闭合单元支架同侧卒中/死亡 HR 为 6.7(95%CI 1.4–31.4,P=.02)。

研究设计与样本

  • 回顾性队列分析 VQI 数据库 2016–2018 年接受远端栓塞保护下 CAS 的患者。
  • 纳入 2671 例 CAS 操作,闭合单元支架 1384 例(51.8%),开放单元支架 1287 例(48.2%)。
  • 排除创伤或夹层 CAS、超过两个治疗病变、使用超过两个颈动脉支架及仅限颈总或颈外动脉的病变。
  • 采用单变量和多变量 logistic 回归比较两种支架设计结局。

主要发现

  • 单变量分析:院内死亡闭合 vs 开放 1.8% vs 1.4%(P=.40),卒中 1.8% vs 2.4%(P=.28),卒中/死亡 3.3% vs 3.5%(P=.81)。
  • 多变量调整后总体院内卒中/死亡无差异(OR 1.08,95%CI 0.68–1.74,P=.74)。
  • 支架设计与病变位置交互作用显著(P=.02);分叉病变闭合单元支架院内卒中/死亡 OR 5.5(95%CI 1.3–22.2,P=.02)。
  • ICA 病变闭合 vs 开放单元支架院内卒中/死亡 OR 0.87(95%CI 0.51–1.45,P=.62)。
  • 1 年随访亚组中,分叉病变闭合单元支架同侧卒中/死亡 HR 6.7(95%CI 1.4–31.4,P=.02)。

临床怎么用

  • 颈动脉分叉病变选择支架时应考虑闭合单元支架可能增加院内卒中/死亡风险。
  • ICA 病变中两种支架设计院内结局无显著差异,可按解剖和操作需求选择。
  • 需改进随访并对病变特异性特征进行深入分析以验证结果。

局限性

  • 1 年随访数据仅覆盖 19% 患者,长期结局解释受限。
  • 为回顾性数据库分析,可能存在未测量混杂。
  • 分叉病变亚组事件数少,OR 和 HR 置信区间宽。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The association between stent design and outcomes after carotid artery stenting (CAS) has remained controversial. The available data are conflicting regarding the superiority of any specific stent design. The present study investigated the association between cell design and outcomes after carotid artery stenting (CAS) in a real world setting. METHODS: Patients who had undergone CAS with distal embolic protection in the Society for Vascular Surgery Vascular Quality Initiative (VQI) database from 2016 to 2018 were included in the present study. Patients undergoing CAS for trauma or dissection or more than two treated lesions were excluded. We also excluded lesions for which more than two carotid stents had been used and lesions confined to the common or external carotid artery. Univariable and multivariable logistic regression analyses were used to compare the outcomes after CAS between the open- and closed-cell stent designs. RESULTS: Of the 2671 CAS procedures included in the present analysis, 1384 (51.8%) had used closed-cell stents and 1287 (48.2%) had used open-cell stents. On univariable analysis, no significant differences were noted between the closed- and open-cell stents in in-hospital mortality (1.8% vs 1.4%; P = .40), stroke (1.8% vs 2.4%; P = .28), and stroke/death (3.3% vs 3.5%; P = .81). After adjusting for potential confounders (ie, age, symptomatic status, previous major amputation, statin and antiplatelet use, American Society of Anesthesiologists class, elective procedures, approach, and post-stent dilatation), no difference was noted in in-hospital stroke/death between the two stent designs (odds ratio [OR], 1.08; 95% confidence interval [CI], 0.68-1.74; P = .74). However, the interaction between stent design (open vs closed) and lesion location (bifurcation vs internal carotid artery [ICA]) was statistically significant (P = .02). Closed-cell stents were associated with five times the odds of in-hospital stroke/death when used in carotid artery bifurcation (OR, 5.5; 95% CI, 1.3-22.2; P = .02). However, when the stent was limited to the ICA, no differences were noted (OR, 0.87; 95% CI, 0.51-1.45; P = .62). One-year follow-up data were available for 19% of patients. No differences in ipsilateral stroke or death at 1 year were noted between the open- and closed-cell stents, except when the lesion was located in the carotid bifurcation (hazard ratio, 6.7; 95% CI, 1.4-31.4; P = .02). CONCLUSIONS: Closed-cell stents were associated with an increased odds of in-hospital stroke/death for carotid bifurcation lesions, which might be related to the relatively lower conformability of closed-cell stents in the tortuous and diameter-mismatched bifurcation anatomy vs the relatively linear uniform diameter of the ICA. Improved follow-up and in-depth analysis of lesion-specific characteristics that might influence the outcomes of these two designs are needed to validate these results.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Faateh M, Dakour-Aridi H, Mathlouthi A, et al. Comparison of open- and closed-cell stent design outcomes after carotid artery stenting in the Vascular Quality Initiative. J Vasc Surg. 2020. PMID: 33080326. doi:10.1016/j.jvs.2020.08.155

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。