裸支架辅助TEVAR治疗急性复杂型B型主动脉夹层的远期结局满意
5年全因死亡率裸支架组为2.4%,单纯TEVAR组为11.9%(log-rank p=0.025);裸支架组1年时胸段和腹段真腔直径增加更明显,完全假腔血栓形成率更高(80.9% vs 47.6%,p=0.005)。
要点
- 裸支架联合TEVAR可显著改善复杂急性B型主动脉夹层患者的5年生存率。
- 裸支架组1年时真腔直径增加更明显且完全假腔血栓形成率更高。
- 两组1年和5年并发症及二次干预率无差异。
核心结论
- 在TEVAR中加用远端裸支架与复杂急性B型主动脉夹层患者长期生存率显著改善相关,可能源于预防真腔塌陷和改善夹层主动脉完全假腔血栓形成。
主要发现
- 5年随访期间,裸支架联合TEVAR组全因死亡1例(2.4%,肺癌),单纯TEVAR组死亡5例(11.9%,其中4例主动脉相关),log-rank p=0.025。
- 两组1年和5年并发症及二次干预率无差异。
- 1年随访时,裸支架联合TEVAR组胸段真腔直径增加(19.7±3.6 vs 17.0±6.2 mm,p=0.018)和腹段真腔直径增加(13.7±4.8 vs 7.2±6.1 mm,p<0.001)均更大,完全假腔血栓形成发生率更高(80.9% vs 47.6%,p=0.005)。
- 1年至5年随访期间,两组主动脉重塑参数变化无差异。
临床怎么用
- 对于复杂急性B型主动脉夹层患者,TEVAR术中可考虑加用远端裸支架以改善远期生存和促进主动脉重塑。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare the clinical outcomes after thoracic endovascular aortic repair (TEVAR) with a bare stent to those after TEVAR alone in patients with complicated acute type B aortic dissection (cATBAD). MATERIALS AND METHODS: A prospective, randomized trial was conducted at 2 medical centers in China between 2010 and 2013. Patients with cATBAD were randomly assigned to receive TEVAR with a bare stent (n=42) or TEVAR only (n=42). Patients were scheduled to undergo computed tomography angiography at 3, 6, and 12 months and then annually to 5 years. The primary endpoint was all-cause mortality at 5 years; secondary outcomes were a composite of complications (endoleak, stent-graft-induced new entry, aortic rupture, and secondary intervention) and aortic remodeling at 1 and 5 years. RESULTS: All-cause death occurred in 1 (2.4%) patient in the TEVAR with bare stent group (lung cancer) and 5 patients (11.9%) in the TEVAR group (4 aorta-related) during the 5-year follow-up (log-rank p=0.025). The 1- and 5-year rates of complications and secondary interventions did not differ between the groups. Patients in the TEVAR with bare stent group had higher increases in the thoracic true lumen diameter (19.7±3.6 vs 17.0±6.2 mm, p=0.018) and abdominal true lumen diameter (13.7±4.8 vs 7.2±6.1 mm, p<0.001) and a higher incidence of complete false lumen thrombosis (80.9% vs 47.6%, p=0.005) at the 1-year follow-up. However, no between-group differences in the changes of aortic remodeling parameters were observed between the 1- and 5-year follow-up periods. CONCLUSION: The addition of a distal bare stent to a thoracic stent-graft during TEVAR was associated with significantly improved long-term survival in cATBAD patients vs TEVAR only, likely due to the prevention of true lumen collapse and improvement of complete false lumen thrombosis of the dissected aorta.
引用
- Lin Y, Dong S, Luo J, et al. Satisfactory Long-term Outcomes of Thoracic Endovascular Aortic Repair With a Bare Stent for Acute Complicated Type B Aortic Dissections. J Endovasc Ther. 2020. PMID: 33118433. doi:10.1177/1526602820966991
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。