术前CT低密度血栓/斑块预测TEVAR术后脊髓缺血
本研究回顾性分析212例胸主动脉腔内修复术(TEVAR)患者,术前CT三维工作站测量降胸主动脉附壁血栓体积与CT值。14例(6.6%)发生脊髓缺血(SCI)。单因素分析显示低密度血栓/斑块是SCI的较强预测因素,提示微栓塞可能是TEVAR后SCI的重要机制。
要点
- 低密度附壁血栓/斑块是TEVAR术后SCI的预测因素
- 微栓塞可能是TEVAR后SCI的重要机制
- 低密度血栓预测SCI或可改变预防策略
核心结论
- 降胸主动脉低密度附壁血栓/斑块是TEVAR术后SCI的预测因素。
- 微栓塞可能是TEVAR术后SCI的重要机制之一。
研究设计与样本
- 单中心前瞻性数据库回顾性分析,2008年10月至2018年12月。
- 367例TEVAR患者排除155例后,最终纳入212例分析。
- 术前CT用三维工作站估算降胸主动脉附壁血栓体积和CT值。
- 采用逻辑回归分析识别SCI危险因素。
主要发现
- 212例中14例(6.6%)TEVAR术后发生SCI。
- 患者平均年龄75.8±6.4岁,女性42例(19.8%)。
- 低密度血栓、总血栓体积、低密度血栓体积、中密度血栓体积、治疗长度、急诊手术和基线透析在SCI与非SCI患者间差异显著。
- SCI事件数少未能行多变量分析;单因素分析中低密度易损血栓/斑块在动脉瘤相关因素中预测SCI较强。
- 远端覆盖T8-L1、左锁骨下动脉覆盖、既往腹主动脉手术和预防性脊髓引流未见显著差异。
关键数值与推荐
- 低密度血栓定义为≥-100 HU但<30 HU。
- 中密度血栓定义为≥30 HU但<150 HU。
临床怎么用
- TEVAR术前CT评估降胸主动脉低密度附壁血栓/斑块有助于识别SCI高风险患者。
局限性
- SCI事件数少,未能进行多变量分析。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Similar to open surgical repair, thoracic endovascular aortic repair (TEVAR) carries a risk of spinal cord ischemia (SCI). However, the generally lower incidence of SCI after TEVAR compared with that after open surgical repair, despite the inability to preserve the intercostal arteries, indicates different pathophysiologic mechanisms with the two procedures. We hypothesized that a microembolism from an aortic mural thrombus is the main cause of SCI. Thus, we evaluated the association between the density of a mural thrombus in the descending thoracic aorta and the development of SCI. METHODS: A retrospective review of a prospectively assembled database was performed for all patients who had undergone surgery at a single institution from October 2008 to December 2018. Patient demographics and procedure-related variables were collected. The volume and Hounsfield unit (HU) value of mural thrombi in the whole descending thoracic aorta were estimated on preoperative computed tomography using a three-dimensional workstation. Logistic regression analysis was performed to identify the risk factors for SCI development. RESULTS: Of the 367 patients who had undergone TEVAR during the study period, 155 were excluded because of previous arch surgery (n = 59), previous descending thoracic aortic surgery (n = 6), previous TEVAR (n = 6), unavailability of optimal preoperative computed tomography data (n = 17), double-barreled dissection (n = 40), and other reasons. The mean ± standard deviation age of the remaining 212 patients was 75.8 ± 6.4 years, and 42 (19.8%) were women. Of the 212 patients, 14 (6.6%) developed SCI after TEVAR. The low mean density of the mural thrombus, total thrombus volume, low-density (≥-100 HU but <30 HU) thrombus volume, intermediate-density (≥30 HU but <150 HU) thrombus volume, treatment length, urgent surgery, and baseline dialysis differed significantly between patients with and without SCI. Although subsequent multivariate analysis could not be performed owing to the small number of SCI events, vulnerable low-density thrombus/plaque was a stronger predictor among the aneurysm-related factors of SCI after TEVAR on univariate analysis. Well-known risk factors, such as distal coverage between T8 and L1, left subclavian artery coverage, previous abdominal aortic surgery, and prophylactic spinal drainage, did not show significant differences. CONCLUSIONS: The results from the present study have demonstrated that among aneurysm-related factors, a lower density mural thrombus/plaque in the descending thoracic aorta is a predictor of SCI development after TEVAR. These results suggest that microembolism is one of the important mechanisms of SCI after TEVAR, which might change the prophylactic strategy.
引用
- Banno H, Kawai Y, Sato T, et al. Low-density vulnerable thrombus/plaque volume on preoperative computed tomography predicts for spinal cord ischemia after endovascular repair for thoracic aortic aneurysm. J Vasc Surg. 2020. PMID: 33068765. doi:10.1016/j.jvs.2020.09.026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。