开窗/分支主动脉腔内修复中右 vs 左上肢入路脑栓塞事件比较
该回顾性研究纳入2013–2018年医师发起IDE研究中的290例f/bEVAR患者,其中270例经上肢12-F鞘入路,比较左(205例)与右(65例)上肢入路的脑栓塞事件。结果显示技术成功率左高于右(99.6% vs 98.4%,p=0.04),卒中发生率左3%、右2%(p>0.99),无显著差异。
要点
- f/bEVAR经上肢入路脑栓塞事件发生率低,左右入路卒中率无显著差异。
- 左上肢入路技术成功率略高(99.6% vs 98.4%,p=0.04),但总辐射暴露更高。
- 栓塞性卒中多与入路同侧(4例),部分累及后循环(3例)。
核心结论
- f/bEVAR经右或左上肢入路脑栓塞事件发生率均低,两组卒中发生率无显著差异。
研究设计与样本
- 回顾性 review,纳入2013–2018年医师发起IDE研究中290例连续f/bEVAR患者。
- 270例(93%)经上肢12-F鞘入路,其中左上肢205例(平均年龄75±8岁,男147例),右上肢65例(平均年龄73±8岁,男42例)。
主要发现
- 技术成功率左上肢99.6% vs 右上肢98.4%(p=0.04)。
- 右上肢入路组胸腹主动脉瘤I–III型比例更高(57% vs 39%,p=0.03)。
- 腔内时间(255±80 vs 246±83分钟,p=0.23)、透视时间(84±32 vs 90±35分钟,p=0.80)、对比剂用量(156±57 vs 153±56 mL,p=0.82)两组相似。
- 总辐射暴露左上肢显著高于右上肢(2463±1912 vs 1757±1494 mGy,p=0.02)。
- 30天或住院期间死亡2例(1%),均与入路部位并发症无关;MAE发生率左上肢32%、右上肢26%(p=0.44)。
临床怎么用
- f/bEVAR选择右上肢或左上肢入路时,脑栓塞风险均低,可依据解剖和操作需求个体化选择。
- 左上肢入路技术成功率略高但总辐射暴露更高,需权衡获益与辐射风险。
局限性
- 回顾性研究设计,存在选择偏倚可能。
- 右上肢入路样本量较小(65例),可能影响统计效能。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the incidence and outcomes of cerebral embolic events when using right (RUE) vs left upper extremity (LUE) access for fenestrated/branched endovascular aneurysm repair (f/bEVAR). MATERIALS AND METHODS: A retrospective review was conducted of 290 consecutive patients enrolled in a physician-sponsored Investigational Device Exemption study to evaluate f/bEVAR between 2013 and 2018. Of these, 270 patients (93%) had an upper extremity access with 12-F sheaths, including 205 patients (mean age 75±8 years; 147 men) with LUE and 65 patients (mean age 73±8 years; 42 men) with RUE access. Outcome measures were technical success, procedural metrics, major adverse events (MAEs), any stroke or transient ischemic attack (TIA), and mortality. RESULTS: Technical success was higher (p=0.04) for LUE (99.6%) vs RUE access (98.4%). Patients treated via RUE access more often had extent I-III thoracoabdominal aortic aneurysms (57% vs 39%, p=0.03). Procedural metrics were similar for LUE vs RUE sides, including endovascular time (255±80 vs 246±83 minutes, respectively; p=0.23), fluoroscopy time (84±32 vs 90±35 minutes, respectively; p=0.80), and contrast volume (156±57 vs 153±56 mL, respectively; p=0.82). Total radiation exposure was significantly higher for LUE vs RUE access (2463±1912 vs 1757±1494 mGy, respectively; p=0.02). There were 2 deaths (1%) at 30 days or during hospital admission, both unrelated to access site complications. MAEs occurred in 32% of patients who had LUE and 26% of those who had RUE access (p=0.44). Five patients (2%) had embolic stroke and none had TIA. Embolic strokes were ipsilateral to the access side in 4 patients and affected the posterior circulation in 3. Two patients (1%) had hemorrhagic strokes. The incidence of stroke was 3% for LUE and 2% for RUE access (p>0.99). CONCLUSION: Fenestrated/branched stent-graft repair was associated with low rates of cerebral embolic events and no significant difference between the right vs left upper extremity approach.
引用
- Mirza AK, Tenorio ER, Marcondes GB, et al. Comparison of Cerebral Embolic Events Between Right and Left Upper Extremity Access During Fenestrated/Branched Endovascular Aortic Repair. J Endovasc Ther. 2020. PMID: 32865146. doi:10.1177/1526602820953511
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。