文献速递主动脉疾病

开源图像处理软件OsiriX Lite用于EVAR支架移植物尺寸规划

Stent Graft Sizing for Endovascular Abdominal Aneurysm Repair Using Open Source Image Processing Software.
PubMed 文献 · Ann Vasc Surg · 2020-09-03

本研究评估开源软件OsiriX Lite与商用软件3Mensio Vascular和Siemens Syngo.via在腹主动脉瘤腔内修复术(EVAR)术前支架尺寸规划中的并发效度。纳入20例EVAR患者的CTA扫描,6名观察者测量20个参数,结果显示16个参数(80%)的观察者间一致性为良好或中等,且三种软件规划时间无显著差异(P=0.88)。

要点

  • OsiriX Lite与商用软件在80%的EVAR规划参数上一致性良好或中等。
  • 三种软件的EVAR规划时间无显著差异(P=0.88)。
  • 开源软件OsiriX Lite可作为EVAR术前尺寸规划的经济替代方案。

核心结论

  • OsiriX Lite是与3Mensio Vascular和Siemens Syngo.via相当的准确且省时的EVAR术前支架尺寸规划图像处理选项。

研究设计与样本

  • 研究纳入20例接受EVAR的腹主动脉瘤患者的CTA扫描,其中10例择期、10例破裂。
  • 6名观察者使用OsiriX Lite(2名)、3Mensio Vascular(3名)和Siemens Syngo.via(1名)测量20个支架尺寸规划参数。
  • 计算每个参数的组内相关系数(ICC)和P值,采用Koo和Li指南解释观察者间一致性,并比较规划时间。

主要发现

  • 三种软件在20个参数中的16个(80%)观察者间一致性为良好或中等。
  • OsiriX Lite规划时间为568秒,3Mensio Vascular为603秒,Siemens Syngo.via为659秒,差异无统计学意义(P=0.88)。

临床怎么用

  • 在缺乏商用软件的机构,可考虑使用免费开源的OsiriX Lite进行EVAR术前支架尺寸规划。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: An important step to reach a favorable outcome of abdominal endovascular aneurysm repair (EVAR) is preoperative sizing of the stent graft using computed tomography angiography (CTA) images of the abdominal aorta. A variety of costly image processing software options is available to obtain the necessary aortic measurements. A package that can be used for EVAR sizing is OsiriX Lite®-an open source, freely downloadable image processing option. This study assesses the concurrent validity of OsiriX Lite® when compared with commercially available 3Mensio Vascular® and Siemens Syngo.via®. METHODS: CTA scans of 20 patients that underwent EVAR for abdominal aneurysm were selected, 10 elective and 10 ruptured. For each scan, 6 observers determined 20 parameters needed for proper stent graft sizing, 2 using Osirix Lite®, 3 using 3Mensio Vascular®, and 1 using Siemens Syngo.via®. For each parameter, an intraclass correlation coefficient (ICC) and a P-value were calculated. Interrater agreement was interpreted using the Koo and Li Guidelines. Time needed to perform EVAR planning was compared. RESULTS: Overall interrater agreement between the 3 sizing options was found to be either "good" or "moderate" for 16 out of 20 parameters (80%). Time needed to perform EVAR planning was not significantly different for Osirix Lite® (568 sec) when compared with 3Mensio Vascular® (603 sec) or Siemens Syngo.via® (659 sec) with a P-value of 0.88. CONCLUSIONS: The authors conclude that Osirix Lite® is an accurate and time-effective image processing option for preoperative sizing of an EVAR stent graft when matched to 3Mensio Vascular® and Siemens Syngo.via®.