文献速递主动脉疾病

EVAR术中覆盖副肾动脉对肾功能的影响

Impact of Accessory Renal Artery Coverage on Renal Function during Endovascular Aortic Aneurysm Repair.
PubMed 文献 · Ann Vasc Surg · 2020-08-12

本研究回顾性纳入2008至2016年间接受EVAR的184例患者,比较覆盖至少一条副肾动脉(ARA组,n=25)与未覆盖ARA(对照组,n=159)的长期肾功能变化。结果显示两组eGFR下降程度及CKD分期恶化比例均无显著差异,但ARA组肾梗死率显著更高;多因素分析中肾上固定是肾功能下降的危险因素。

要点

  • EVAR中覆盖副肾动脉不显著影响长期肾功能。
  • 覆盖副肾动脉者肾梗死率显著升高。
  • 肾上固定是肾功能下降的独立危险因素。

核心结论

  • EVAR术后覆盖副肾动脉似乎不影响长期肾功能。
  • 肾上固定导致肾功能下降更明显。

研究设计与样本

  • 回顾性单中心研究,纳入2008至2016年接受EVAR的患者184例。
  • ARA组25例,对照组159例;平均随访41.6±25.8个月。

主要发现

  • 术前eGFR在ARA组为68.9±17.8 mL/min/1.73 m2,对照组为72.5±17.4 mL/min/1.73 m2(P=0.33)。
  • 随访期间eGFR下降值ARA组为-6.52±11.6,对照组为-6.43±13.8(P=0.97)。
  • CKD分期恶化比例ARA组32%,对照组35.2%(P=0.75)。
  • 肾梗死率ARA组96%,对照组1.9%(P<0.0001)。
  • 多因素分析中肾上固定为肾功能下降的危险因素(OR=2.01,95%CI 1.05-3.84,P=0.04)。

临床怎么用

  • EVAR术前规划时可考虑覆盖副肾动脉而不必过度担忧长期肾功能损害。
  • 对于采用肾上固定的EVAR患者,应加强术后肾功能监测。

局限性

  • 回顾性单中心研究,样本量有限。
  • ARA组样本量较小(n=25)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Long-term outcomes of accessory renal artery (ARA) coverage after endovascular aneurysm repair (EVAR) are unknown. We analyzed the impact of ARA coverage on renal function long-term. METHODS: This retrospective, monocentric study included patients treated by EVAR between 2008 and 2016. Patients with at least one ARA covered with EVAR (ARA group) were compared with patients with no covered ARA (control group). Renal function was determined by estimating the glomerular filtration rate (eGFR) and graded according to chronic kidney disease (CKD) classification stages. RESULTS: A total of 184 patients were included (ARA group, n = 25; control group, n = 159). Renal risk factors were similar in the 2 groups. Mean (±standard deviation) duration of follow-up was 41.6 ± 25.8 months. Preoperative eGFR (mL/min/1.73 m2) was 68.9 ± 17.8 in the ARA group and 72.5 ± 17.4 in the control group (P = 0.33), with a similar decline in the 2 groups during follow-up (-6.52 ± 11.6 ARA group vs. -6.43 ± 13.8 control group; P = 0.97). At the end of the study, 8 ARA patients and 56 controls had deteriorated by one CKD stage (32% vs. 35.2%, respectively; P = 0.75). Rate of renal infarction was significantly higher in the ARA group (96% vs. 1.9%; P < 0.0001). In multivariate analysis, suprarenal fixation was identified as a risk factor for a decline in renal function (odds ratio = 2.01 [95% confidence interval: 1.05-3.84]; P = 0.04). CONCLUSIONS: ARA coverage after EVAR does not appear to affect renal function long-term. Suprarenal fixation led to a greater decline in renal function.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Salomon du Mont L, Agag G, Malakhia A, et al. Impact of Accessory Renal Artery Coverage on Renal Function during Endovascular Aortic Aneurysm Repair. Ann Vasc Surg. 2020. PMID: 32795649. doi:10.1016/j.avsg.2020.07.053

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。