文献速递主动脉疾病内脏/肾动脉与血管畸形

漂浮支架移植物辅助重建不良肾动脉:多层分支覆膜支架修复夹层后胸腹主动脉瘤

Floating Stent-Graft as a Support to Bridge an Unfavorable Renal Artery During Postdissection TAAA Repair Using a Multibranched Thoracoabdominal Endograft.
PubMed 文献 · J Endovasc Ther · 2020-07-30

本文报告一例77岁女性夹层后胸腹主动脉瘤患者,既往曾行腹主动脉瘤开放修复及PETTICOAT技术处理B型夹层。在使用Zenith t-Branch行急诊血管腔内修复时,左肾动脉插管失败,遂于瘤腔内放置「漂浮」Viabahn支架移植物提供支撑,成功经裸支架将桥接支架送入左肾动脉。手术成功隔绝动脉瘤并保留所有目标血管灌注,无神经并发症,6个月随访桥接支架通畅。

要点

  • 夹层后TAAA行多层分支覆膜支架修复时,PETTICOAT裸支架与不良靶动脉解剖可增加技术难度。
  • 瘤腔内「漂浮」支架移植物可为桥接支架的推进和释放提供额外支撑。
  • 该技术成功隔绝动脉瘤并保留目标血管灌注,6个月随访桥接支架通畅。

核心结论

  • 复杂血管腔内TAAA术后重塑改变常需在二次手术中采用创新技术和材料。
  • 「漂浮」支架移植物可通过为桥接支架的推进和释放提供额外支撑,帮助到达困难靶血管。

研究设计与样本

  • 技术报告,演示一例77岁女性患者的血管腔内处理技术。
  • 患者既往有腹主动脉瘤开放修复史,7年前因急性Stanford B型夹层行胸主动脉覆膜支架及主动脉裸Z支架(PETTICOAT)植入。
  • 本次因症状性、快速增长的夹层后TAAA,计划使用Zenith t-Branch行血管腔内治疗。

主要发现

  • 左肾动脉标准插管技术失败后,采用补救操作将「漂浮」Viabahn支架移植物置于动脉瘤囊内以提供足够支撑。
  • 经裸支架将桥接支架移植物送达目标左肾动脉。
  • 手术成功隔绝TAAA并保留所有目标血管灌注,无神经并发症。
  • 6个月影像随访证实桥接支架通畅。

临床怎么用

  • 在复杂血管腔内TAAA二次手术中,遇靶动脉解剖不良且标准插管失败时,可考虑瘤腔内「漂浮」支架移植物辅助桥接支架到位。
  • 术前应评估既往PETTICOAT裸支架等植入物对靶血管插管和桥接支架释放路径的影响。

局限性

  • 本文为单例技术报告,结果不可外推至所有夹层后TAAA患者。
  • 随访时间仅6个月,长期通畅性和耐久性未报告。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Purpose: To report an unusual endovascular technique to manage unfavorable renal artery anatomy encountered in an urgent case of symptomatic postdissection thoracoabdominal aortic aneurysm (TAAA) treated with an off-the-shelf multibranched device. Technique: The technique is demonstrated in a 77-year-old woman who had a history of previous open abdominal aortic aneurysm repair and an emergent procedure to implant a thoracic endograft and an aortic bare Z-stent (PETTICOAT) for acute Stanford type B dissection 7 years prior. The patient presented with a symptomatic, rapidly growing, postdissection TAAA. Endovascular treatment with a Zenith t-Branch was planned. After standard catheterization techniques failed in the left renal artery, a bailout maneuver was utilized to place a "floating" Viabahn stent-graft in the aneurysm sac to create sufficient support to deliver the bridging stent-grafts through the bare stent to the target left renal artery. The procedure was successful in excluding the TAAA and preserving perfusion to all target vessels. No neurological complications occurred. Six-month imaging follow-up confirmed the patency of the bridging stents. Conclusion: Remodeling changes after complex endovascular TAAA procedures often require the use of innovative techniques and materials during secondary procedures. In this case, the presence of a post-PETTICOAT bare aortic stent and hostile target artery anatomy increased the technical difficulty of t-Branch implantation. A "floating" stent-graft could be useful to reach challenging target vessels by providing additional support to bridging stent advancement and deployment.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Rossi G, Perini P, Tecchio T, et al. Floating Stent-Graft as a Support to Bridge an Unfavorable Renal Artery During Postdissection TAAA Repair Using a Multibranched Thoracoabdominal Endograft. J Endovasc Ther. 2020. PMID: 32729774. doi:10.1177/1526602820943857

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。