文献速递主动脉疾病外周动脉疾病

髂分支装置在腹主动脉假性动脉瘤伴极窄远端主动脉中的应用

Endovascular Treatment of an Abdominal Aortic FALSE Aneurysm with a Very Narrow Distal Aorta and Aortic Lumen Using an Iliac Branch Device.
PubMed 文献 · Ann Vasc Surg · 2020-07-04

本文报道一例76岁男性腹主动脉假性动脉瘤合并极窄远端主动脉(10 mm)及严重髂动脉闭塞病变的病例。因合并症多无法开放手术,采用髂分支装置(IBD)于主动脉分叉处行全腔内修复,将分支桥接至一侧髂动脉并近端延长至肾动脉,技术可行。

要点

  • 极窄远端主动脉(10 mm)使经典分叉型EVAR不适用。
  • IBD置于主动脉分叉处可作为全腔内替代方案。
  • 适用于开放手术高危的腹主动脉假性动脉瘤患者。

核心结论

  • 对极窄远端主动脉患者,分叉型EVAR可能不适用,于主动脉分叉处使用IBD可行。

研究设计与样本

  • 单病例报告:76岁男性,腹主动脉假性动脉瘤合并极窄远端主动脉(10 mm)及严重髂动脉闭塞病变。

主要发现

  • 患者主动脉管腔及分叉处极窄(10 mm), preclude经典分叉型EVAR。
  • 因合并症多无法开放手术,采用IBD于主动脉分叉处行全腔内修复。
  • 将IBD分支以球囊扩张覆膜支架桥接至一侧髂动脉,主件近端以主动脉袖套延长至肾动脉。

临床怎么用

  • 对极窄远端主动脉且开放手术高危者,可考虑IBD置于主动脉分叉处行全腔内修复。

局限性

  • 单病例报告,结论需更大样本验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: A narrow distal aorta (NDA) makes endovascular aortic repair (EVAR) challenging and prone to immediate and late complications. We describe a case of an abdominal aortic false aneurysm (AAFA) with an NDA and iliac occlusive disease that was treated by an iliac branch device (IBD) placed at the aortic bifurcation. CASE REPORT: A 76-year-old male patient suffering from severe bilateral calf claudication presented to our clinic. He had a history of ischemic heart disease, diabetes mellitus, and left colectomy for colon cancer. His workup revealed an AAFA with severe iliac occlusive disease. His aortic lumen and his aortic bifurcation were very narrow (10 mm) precluding a classic bifurcated EVAR. An open repair was not possible because of his multiple comorbidities. We successfully used an IBD by placing its Y configuration at the level of the aortic bifurcation, bridging the branch into one iliac artery with a balloon-expandable covered stent and extending the main component proximally up to the renal arteries with an aortic cuff. CONCLUSIONS: Bifurcated EVAR may not be suitable in patients with an NDA. Using an IBD at the level of the aortic bifurcation is feasible. This technique offers a total endovascular solution in high-risk patients for open repair.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Gemayel G. Endovascular Treatment of an Abdominal Aortic FALSE Aneurysm with a Very Narrow Distal Aorta and Aortic Lumen Using an Iliac Branch Device. Ann Vasc Surg. 2020. PMID: 32634556. doi:10.1016/j.avsg.2020.06.060

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。