文献速递主动脉疾病

血管腔内主动脉修复中辐射剂量的综合文献综述

Editor's Choice - Comprehensive Literature Review of Radiation Levels During Endovascular Aortic Repair in Cathlabs and Operating Theatres.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2020-07-15

该综述检索MEDLINE和Cochrane数据库近10年文献,纳入报告标准EVAR和复杂腹主动脉腔内修复(F/BEVAR)辐射剂量数据的研究。结果显示杂交手术室剂量面积乘积最低,固定系统最高;遵循ALARA原则时剂量报告趋于最低;多项F/BEVAR研究报道患者和 staff 辐射水平令人担忧。

要点

  • 杂交手术室在EVAR和F/BEVAR中记录的剂量面积乘积最低。
  • 固定成像系统记录的剂量面积乘积最高。
  • 遵循ALARA原则及使用融合技术有助于降低辐射剂量。

核心结论

  • 现代成像设备类型、团队参与辐射管理和融合等新技术有助于降低标准和复杂EVAR的辐射剂量。
  • 每个开展主动脉瘤腔内治疗的中心应考虑投资现代成像技术。

研究设计与样本

  • 文献综述,由两名独立研究者检索MEDLINE和Cochrane数据库,检索词为「aortic aneurysms」「radiation」「humans」,检索周期10年。
  • 纳入英文全文且独立于成像设备类型报告辐射数据的研究,排除实验性研究。

主要发现

  • EVAR和F/BEVAR中最低剂量面积乘积水平见于杂交手术室,最高见于固定系统。
  • 当作者规定遵循ALARA原则时,剂量报告趋于最低。
  • 多项研究尤其是F/BEVAR研究报道患者和 staff 的辐射水平令人担忧。

临床怎么用

  • 开展EVAR和F/BEVAR的中心应优先选用杂交手术室等低剂量成像设备。
  • 团队应积极参与辐射管理并遵循ALARA原则。
  • 可借助融合等新技术降低标准与复杂EVAR的辐射剂量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Occupational exposure is a growing concern among the endovascular specialist community. Several types of imaging equipment are available, such as mobile C arms or hybrid rooms, and some have been shown to deliver higher levels of radiation. A literature review was conducted to identify studies reporting dose data during standard (EVAR) and complex abdominal aortic endovascular repair (fenestrated/branched EVAR [F/BEVAR]). METHODS: A search of the MEDLINE and the Cochrane databases was performed by two independent investigators using the medical subject heading terms "aortic aneurysms", "radiation", and "humans" over a search period of 10 years. Studies with full text available in English and reporting radiation data independently from the imaging equipment type were included. Experimental studies were excluded. RESULTS: The lowest dose-area product levels during EVAR and F/BEVAR were identified in hybrid rooms, while the highest were with fixed systems. When adherence to the as low as reasonably achievable principles was stipulated by the authors, dose reports tended to be among the lowest. Several studies, especially of F/BEVAR, report concerning levels of radiation for both patients and staff. CONCLUSION: Modern imaging equipment type, team involvement with radiation management, and the support of recent imaging technologies such as fusion help to reduce the dose delivered during standard and complex EVAR. Investment in modern imaging technology should be considered in every centre providing endovascular management of aortic aneurysms.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. Hertault A, Bianchini A, Amiot S, et al. Editor's Choice - Comprehensive Literature Review of Radiation Levels During Endovascular Aortic Repair in Cathlabs and Operating Theatres. Eur J Vasc Endovasc Surg. 2020. PMID: 32682690. doi:10.1016/j.ejvs.2020.05.036

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。