二氧化碳数字减影血管造影联合术中超声造影辅助EVAR的单中心经验
BACKGROUND: Allergy to iodinated contrast (IC) agent and advanced chronic kidney disease are major limitations to endovascular repair (EVAR) of abdominal aortic aneurysms (AAAs).…
要点
- CO2-DSA联合CEUS可安全用于碘对比剂禁忌的腹主动脉瘤EVAR,技术成功率高。
- CO2造影对I型内漏敏感,对II型内漏敏感性较低,CEUS可补充确认。
- 该策略可减少或避免碘对比剂使用,术后肾功能无显著恶化。
核心结论
- 对于碘对比剂禁忌的腹主动脉瘤患者,CO2-DSA联合CEUS辅助EVAR可安全有效地减少或避免碘对比剂使用,中期结果满意。
研究设计与样本
- 入选标准为估计肾小球滤过率<40 mL/min且解剖适合常规肾下型EVAR。
主要发现
- 9例实现完全无碘对比剂EVAR,其余6例因辅助操作需使用碘对比剂。
- CO2完成造影检出所有I型内漏(2例Ia,1例Ib),但对II型内漏敏感性较低。
- 术中CEUS确认所有I型内漏及2例II型内漏。
- 中位住院时间为4天,术后未见肾功能显著恶化。
临床怎么用
- 对碘对比剂过敏或晚期慢性肾病的腹主动脉瘤患者,可考虑CO2-DSA联合CEUS辅助EVAR以减少碘对比剂需求。
- 术中CEUS可作为CO2造影的补充,用于确认内漏。
局限性
- 单中心小样本观察性研究,结果需更大规模研究验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Allergy to iodinated contrast (IC) agent and advanced chronic kidney disease are major limitations to endovascular repair (EVAR) of abdominal aortic aneurysms (AAAs). We describe our experience combining CO2-assisted EVAR with intraoperative contrast-enhanced ultrasound (CEUS) in an attempt to avoid contrast-induced allergy or nephropathy. METHODS: Observational cohort study using prospectively acquired data on patients undergoing CO2-assisted EVAR in single institution. EVAR planning was performed using computed tomographic angiography or magnetic resonance aortography in patients contraindicated for IC. Patients were considered if their estimated glomerular filtration rate was <40 mL/min and anatomically suitable for conventional infrarenal EVAR. Outcomes of interest included technical success rate and reintervention rates, total radiation dose, length of hospital stay, and graft kinking or migration. RESULTS: Fifteen patients (10 male) were treated across a 5-year period. Technical success was achieved in all cases. Completely IC-free EVAR was performed in 9 cases, whereas the remaining 6 required IC administration for adjunct procedures. CO2 completion angiography detected all type I endoleaks (2 Ia and 1 Ib) but was less sensitive to type II. Intraoperative CEUS confirmed all type I and 2 cases of type II endoleaks. Median hospital stay was 4 days. No significant deterioration in renal function was seen postoperatively. CONCLUSIONS: In patients with abdominal aortic aneurysms and with contraindication for IC, a combined approach of using CO2 digital subtraction angiography and CEUS can be used safely and efficiently to minimize or obviate the need for IC agents with satisfactory mid-term results.
引用
- Tantawy TG, Seriki D, Rogers S, et al. Endovascular Aneurysm Repair Assisted by CO2 Digital Subtraction Angiography and Intraoperative Contrast-Enhanced Ultrasonography: Single-Center Experience. Ann Vasc Surg. 2020. PMID: 32599109. doi:10.1016/j.avsg.2020.06.036
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。