文献速递外周动脉疾病

CUSA脱钙技术治疗股动脉分叉严重钙化病变的疗效

Efficacy of the Decalcification of Heavily Calcified Femoral Bifurcation Lesions Using a Cavitron Ultrasonic Surgical Aspirator.
PubMed 文献 · Ann Vasc Surg · 2020-05-29

本研究纳入26条接受CUSA脱钙技术治疗的肢体,评估其血流动力学和形态学效果。结果显示ABI和CFA面积均显著改善,2年通畅率100%,再狭窄率低,提示该技术安全有效。

要点

  • CUSA脱钙技术血流动力学成功率达96.2%,技术成功率达100%
  • 术后2年CFA一期和二期通畅率均为100%
  • CFA再狭窄率7.6%,同侧肢体免于再干预率2年时为88.5%

核心结论

  • CUSA脱钙技术是治疗严重钙化股动脉病变的安全有效替代方法,通畅率高且再狭窄率低。

研究设计与样本

  • 回顾性研究纳入2014至2017年26条接受CUSA脱钙技术治疗的肢体,采用ABI和CTA进行血流动力学和形态学评估。

主要发现

  • 血流动力学成功率为96.2%(术前ABI 0.37±0.28,术后ABI 0.75±0.15,P<0.0001)。
  • 技术成功率为100.0%(术前CFA面积4.1±5.9 mm2,术后CFA面积46.1±17.0 mm2,P<0.0001)。
  • 临床改善率为95.8%。
  • 术后2年CFA一期和二期通畅率均为100.0%,同侧肢体免于再干预率为88.5%。
  • 中位随访28.0个月(范围12.3-67.0个月)期间,CFA再狭窄率(定义为横截面积减少>50%)为7.6%。

临床怎么用

  • 对于严重钙化股动脉分叉病变,可考虑使用CUSA脱钙技术作为传统内膜剥脱术的替代方法。

局限性

  • 样本量较小(26条肢体),且为回顾性研究,需更大规模研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In the current diabetes era, severe calcified femoral bifurcation lesions extending to the external elastic lamina are sometimes experienced and are technically challenging during conventional endarterectomy. We previously reported an alternative method, a decalcification technique with a Cavitron Ultrasonic Surgical Aspirator (CUSA), for calcified lesions. This study aimed to clarify the efficacy of CUSA decalcification technique. METHODS: A total of 26 limbs treated with CUSA decalcification from 2014 to 2017 were enrolled and evaluated hemodynamically with ankle-brachial index (ABI) and morphologically with computed tomography angiography (CTA). ABI was measured every 6 months, and CTA was performed early after surgery and then annually thereafter. Curved planar reformation images and cross-sectional multiplanar reconstruction images obtained by CTA were used to measure the cross-sectional area of the common femoral artery (CFA). Then, the time courses of the ABI and CFA areas were analyzed. RESULTS: The operative indication was claudication in 80.8%, rest pain in 7.7%, and tissue loss in 11.5% of the cases. A concomitant profundaplasty was performed in 34.6% of the cases. One case of an intraoperative arterial wall perforation was experienced as a procedure-related complication. Hemodynamic success rate was 96.2% (preoperative ABI: 0.37 ± 0.28, postoperative ABI: 0.75 ± 0.15, P < 0.0001) and technical success rate was 100.0% (preoperative CFA area: 4.1 ± 5.9 mm2, postoperative CFA area: 46.1 ± 17.0 mm2, P < 0.0001), with clinical improvement achieved in 95.8% of cases. Primary and secondary patency rates of the CFA were 100.0% at 2 years postoperatively, and the reintervention-free rate for the ipsilateral limb was 88.5% at 2 years postoperatively. Over a median follow-up period of 28.0 months (range, 12.3-67.0 months), the restenosis rate of CFA was 7.6%, when restenosis was defined as a >50% decrease in cross-sectional area. CONCLUSIONS: CUSA decalcification is a safe and effective alternative method to treat heavily calcified femoral lesions with a good patency rate and a low restenosis rate.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Miyake K, Nakamura T, Fujimura H, et al. Efficacy of the Decalcification of Heavily Calcified Femoral Bifurcation Lesions Using a Cavitron Ultrasonic Surgical Aspirator. Ann Vasc Surg. 2020. PMID: 32479872. doi:10.1016/j.avsg.2020.05.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。