3D打印引导开窗支架治疗胸腹主动脉疾病
本研究回顾性总结34例胸腹主动脉疾病患者,采用3D打印模型引导术中自制开窗支架进行全腔内修复。结果表明该技术可安全、可靠地用于涉及关键分支的胸腹主动脉疾病,短期随访显示其准确性可能优于传统测量方法,但仍需进一步研究。
要点
- 3D打印模型可指导术中精准开窗,平均定制时间1.3小时。
- 34例患者共制作107个开窗,使用102个桥接支架。
- 术后1例死亡(3%),无肾功能不全或截瘫发生。
核心结论
- 3D打印可引导开窗支架的制作,用于治疗涉及关键分支的胸腹主动脉疾病。
- 该技术短期随访显示安全可靠,准确性可能优于传统测量方法。
研究设计与样本
- 单中心回顾性研究,纳入2018年4月至2019年3月34例胸腹主动脉疾病患者(平均年龄58±14岁,24例男性)。
- 其中胸腹主动脉夹层19例,胸腹主动脉瘤15例。
主要发现
- 打印过程约5小时(图像重建1小时,打印3小时,后处理1小时)。
- 医师自制支架共107个开窗,由102个桥接支架固定(73个覆膜支架,29个裸支架)。
- 平均手术时间5.6±1.2小时,其中支架定制平均1.3小时。
- 术中丢失2条分支动脉;1例(3%)术后1周死于逆行夹层破裂;1例术后出现轻微脑梗死。
- 平均随访8.5个月,1例开窗内漏(弹簧圈栓塞),4例远端夹层破裂(3例治疗,1例观察)。
临床怎么用
- 对于涉及关键分支的胸腹主动脉疾病,可考虑采用3D打印模型引导术中开窗支架定制。
- 该技术可能提高开窗定位的准确性,但需注意术中分支丢失及术后内漏、远端破裂等风险。
局限性
- 样本量较小(34例),随访时间较短(平均8.5个月)。
- 作者指出仍需进一步研究和发展。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Purpose: To summarize the experience and outcomes of total endovascular repair of thoracoabdominal aortic disease using 3-dimensional (3D) printed models to guide on-site creation of fenestrations in aortic stent-grafts. Materials and Methods: From April 2018 to March 2019, 34 patients (mean age 58±14 years; 24 men) with thoracoabdominal aortic disease were treated in our department. Nineteen patients had thoracoabdominal aortic dissection and 15 had thoracoabdominal aortic aneurysm. Preoperatively, a 3D printed model of the aorta was made according to computed tomography images. In the operating room, the main aortic stent-graft was completely released in the 3D printed model, and the position of each fenestration or branch was marked on the stent-graft. The fenestrations were then made using an electric pen. Wires were sewn to the edge of the fenestrations using nonabsorbable sutures. After customization, the aortic stent-graft was reloaded into the delivery sheath and deployed. Results: The printing process took ~5 hours (1 hour for image reconstruction, 3 hours for printing, and 1 hour for postprocessing). The physician-modified stent-grafts had a total of 107 fenestrations secured by 102 bridging stent-grafts, including 73 covered stents and 29 bare stents. The average procedure time was 5.6±1.2 hours, including a mean 1.3 hours for stent-graft customization. No renal insufficiency or paraplegia occurred. Two branch arteries were lost during the operation. One patient (3%) died 1 week after surgery from a retrograde dissection rupture. One patient developed a minor cerebral infarction postoperatively. The mean follow-up time was 8.5 months. There was 1 endoleak from a fenestration (coil embolized) and 4 distal ruptures of the aortic dissection (3 treated and 1 observed). Conclusion: Three-dimensional printing can be used to guide creation of fenestrated stent-grafts for the treatment of thoracoabdominal aortic diseases involving crucial branches. This technique appears to be more accurate than the traditional measurement method, with short-term follow-up demonstrating the safety and reliability of the method. However, further research and development are needed.
引用
- Tong YH, Yu T, Zhou MJ, et al. Use of 3D Printing to Guide Creation of Fenestrations in Physician-Modified Stent-Grafts for Treatment of Thoracoabdominal Aortic Disease. J Endovasc Ther. 2020. PMID: 32517556. doi:10.1177/1526602820917960
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。