胸主动脉腔内修复对亚洲B型主动脉夹层患者主动脉重塑的影响
24个月时,TEVAR组与OMT组最大主动脉直径差异分别为-7.7 mm和+1.9 mm(P=0.077),真腔直径差异分别为+10.0 mm和+2.6 mm(P=0.049),假腔血栓形成率分别为100%和20%(P=0.012)。结论:在亚洲TBAD人群中,TEVAR联合OMT较单纯OMT对主动脉重塑有显著积极作用。
要点
- TEVAR组24个月真腔直径增加显著优于OMT组(+10.0 mm vs +2.6 mm,P=0.049)。
- TEVAR组假腔完全血栓形成率显著高于OMT组(100% vs 20%,P=0.012)。
- 两组30天和2年死亡率无显著差异。
核心结论
- 在亚洲TBAD人群中,TEVAR联合OMT较单纯OMT对主动脉重塑有显著积极作用。
研究设计与样本
- 单中心前瞻性数据库的回顾性研究,纳入2008年1月至2015年12月急性TBAD患者44例。
- OMT组中6例因影像学疾病进展在6周后交叉至择期TEVAR。
主要发现
- 24个月时,TEVAR组与OMT组平均最大主动脉直径差异分别为-7.7 mm和+1.9 mm(P=0.077)。
- 24个月时,TEVAR组与OMT组平均真腔直径差异分别为+10.0 mm和+2.6 mm(P=0.049)。
- 24个月时,TEVAR组与OMT组假腔血栓形成率分别为100%和20%(P=0.012)。
- Kaplan-Meier分析显示两组30天和2年死亡率无显著差异。
临床怎么用
- 对于亚洲TBAD患者,TEVAR联合OMT可促进主动脉重塑,表现为真腔直径增加和假腔血栓形成。
- TEVAR并未显著改善30天和2年死亡率,临床决策需综合评估。
局限性
- 单中心回顾性研究,样本量较小(n=44)。
- OMT组存在交叉至TEVAR的情况,可能影响组间比较。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Management of uncomplicated type B aortic dissection (TBAD) has traditionally been aggressive medical therapy. Recent studies brought about a paradigm shift with evidence to suggest benefits from early endovascular intervention to a high risk subgroup of acute uncomplicated TBAD patients. AIMS: We aim to review the effects of aortic remodeling in Asian patients with TBAD with and without endovascular intervention, including maximal aortic diameter, true lumen diameter, and false lumen thrombosis. METHODS: This is a single-center retrospective study of a prospective database. Patients who presented to our institution with acute TBAD from January 2008 to December 2015 (n = 44) were evaluated. Eighteen percent (8 patients) presented with complicated TBAD and underwent emergency thoracic endovascular aortic repair (TEVAR) while the remaining 82% (36 patients) were treated with optimal medical therapy (OMT). RESULTS: Six patients under the conservative arm crossed over to elective TEVAR after 6 weeks because of interval radiological progression of disease. There was no significant difference in the baseline demographics of the TEVAR group and the OMT group. At 24 months, mean maximal aortic diameter difference was -7.7 mm and +1.9 mm (P = 0.077), mean true lumen diameter difference was +10.0 mm and +2.6 mm (P = 0.049), and false lumen thrombosis was 100% and 20% (P = 0.012) for TEVAR and OMT, respectively. Kaplan-Meier analysis showed no significant difference in mortality between the 2 groups at 30 days and 2 years. CONCLUSIONS: Within an Asian population with TBAD, TEVAR with OMT has a significant positive effect on aortic remodeling, compared with OMT-only management.
引用
- Tang JH, Lo ZJ, Wong J, et al. Effect of Thoracic Endovascular Aortic Repair on Aortic Remodeling in Patients with Type B Aortic Dissection in an Asian Population. Ann Vasc Surg. 2020. PMID: 32502679. doi:10.1016/j.avsg.2020.05.058
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。