文献速递主动脉疾病

杂交手术室与传统手术室C臂下肾下腹主动脉瘤腔内修复术的对比

Endovascular Infrarenal Aortic Aneurysm Repair Performed in a Hybrid Operating Room Versus Conventional Operating Room Using a C-Arm.
PubMed 文献 · Ann Vasc Surg · 2020-06-03

单中心回顾性研究比较杂交手术室固定血管造影设备与传统手术室移动C臂在标准EVAR中的造影剂用量和辐射暴露。共纳入77例患者,杂交手术室组造影剂用量更少但辐射剂量更高,透视时间和手术时间无差异,30天并发症和死亡率无差异。

要点

  • 杂交手术室EVAR造影剂用量更少(108.6 mL vs 162.5 mL,P<0.001)。
  • 杂交手术室EVAR辐射剂量更高(154 Gy cm2 vs 61.5 Gy cm2,P<0.001)。
  • 两组的透视时间、手术时间及30天结局无显著差异。

核心结论

  • 常规EVAR在杂交手术室固定成像系统下可能减少造影剂用量,但辐射暴露更高。
  • 移动C臂更换为杂交手术室时显著增加的辐射暴露不应被低估。

研究设计与样本

  • 单中心回顾性研究,2016年5月至2019年8月,连续纳入标准EVAR患者77例。
  • 传统手术室组42例使用移动C臂,杂交手术室组35例使用固定血管造影设备。

主要发现

  • 杂交手术室组造影剂用量低于传统手术室组(108.6 mL [±41.5] vs. 162.5 mL [±52.6];P < 0.001)。
  • 杂交手术室组辐射剂量高于传统手术室组(154 Gy cm2 [±102.9] vs. 61.5 Gy cm2 [±42.4];P < 0.001)。
  • 两组透视时间(20.4 min [±8.5] vs. 23.2 min [±12.4];P = 0.274)和总手术时间(106.4 [±22.3] vs. 109.4 [±25.8];P = 0.798)无差异。
  • 两组30天并发症率和手术死亡率无差异。
  • 传统手术室组DAP与BMI正相关(rs=0.580;P < 0.001),杂交手术室组无相关性(rs=0.408;P = 0.028)。

临床怎么用

  • 杂交手术室行EVAR时应关注辐射防护,尤其对BMI较高患者。
  • 选择手术室设备时需权衡造影剂用量减少与辐射暴露增加。

局限性

  • 单中心回顾性研究,样本量有限(77例)。
  • 两组手术时间跨不同时间段,可能存在时间偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: To compare contrast usage and radiation exposure during endovascular aneurysm repair (EVAR) using mobile C-arm imaging in a conventional operating room (OR) or fixed angiographic equipment in a hybrid OR (HR). METHODS: A retrospective unicenter study from May 2016 to August 2019. All consecutive patients undergoing standard EVAR were included. Patients were divided into 2 groups. Group OR included EVARs performed in a conventional OR with a mobile C-arm (May 2016 to April 2018) and group HR included EVARs performed with a fixed angiographic equipment in an HR (May 2018 to August 2019). Data collected included patient demographics, aneurysm diameter, neck length, radiation dose: median dose-area product (DAP), fluoroscopy time, total operative time, contrast use, and 30-day clinical outcomes. RESULTS: A total of 77 patients were included in the study (42 patients in group OR and 35 patients in group HR). There was no difference in age, body mass index (BMI), mean aneurysm, and neck length between groups. Patients in the group HR received less contrast volume (108.6 mL [±41.5] vs. 162.5 mL [±52.6]; P < 0.001), but higher radiation dose (154 Gy cm2 [±102.9] vs. 61.5 Gy cm2 [±42.4]; P < 0.001). There were no differences in fluoroscopy time (20.4 min [±8.5] vs. 23.2 min [±12.4]; P = 0.274) and total operative time (106.4 [±22.3] vs. 109.4 [±25.8]; P = 0.798). No difference was found in terms of 30-day complication rates or operative mortality between groups. DAP was positively correlated with BMI in the group OR (Spearman's rank correlation coefficient rs, 0.580; P < 0.001), but no correlation could be seen in the group HR (rs, 0.408; P = 0.028). CONCLUSIONS: Routine EVAR performed in a hybrid fixed-imaging suite may be associated with less contrast usage, but higher radiation exposure in our center. The significantly higher radiation exposure when the mobile C-arm is replaced by an HR should not be underestimated.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Martínez LI, Esteban C, Riera C, et al. Endovascular Infrarenal Aortic Aneurysm Repair Performed in a Hybrid Operating Room Versus Conventional Operating Room Using a C-Arm. Ann Vasc Surg. 2020. PMID: 32504790. doi:10.1016/j.avsg.2020.05.065

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。