文献速递主动脉疾病颈动脉与弓上血管

开窗与扇形定制支架在主动脉弓0区和1区的应用中远期结果

Fenestrated and Scalloped Endovascular Grafts in Zone 0 and Zone 1 for Aortic Arch Disease.
PubMed 文献 · Ann Vasc Surg · 2020-06-15

该回顾性研究纳入14例主动脉弓疾病患者,使用扇形或开窗定制支架在0区或1区行TEVAR以保留弓上分支血流。技术成功率100%,围术期1例致死性卒中(7%),中位随访37.5个月无其他死亡,靶血管均通畅;1区扇形支架组2例(14%)出现晚期内漏,开窗支架组无内漏。

要点

  • 扇形或开窗定制支架在0/1区TEVAR技术可行,可保留弓上分支血流。
  • 围术期致死性卒中发生率为7%(1/14),见于开窗保留无名动脉且弓部有动脉粥样硬化斑块者。
  • 1区扇形支架晚期内漏发生率为14%(2/14),开窗支架组无内漏。

核心结论

  • 在解剖条件允许时,使用扇形或开窗定制支架在0区和1区行TEVAR是治疗累及弓上分支的主动脉弓疾病的可行技术。

研究设计与样本

  • 回顾性分析前瞻性收集的数据,纳入连续14例接受扇形或开窗Relay Plus定制支架(Terumo Aortic)在0区或1区锚定的主动脉弓疾病患者。
  • 患者中位年龄66岁(范围48-84),男性9例、女性5例;0区6例,1区8例。

主要发现

  • 技术成功率100%,完成造影未见内漏。
  • 围术期1例致死性卒中(7%),见于开窗保留无名动脉且弓部有动脉粥样硬化斑块的患者。
  • 中位随访37.5个月(范围3-72),无其他死亡,所有靶血管和颈部血运重建均保持通畅,无截瘫、无逆行夹层及其他并发症。
  • 1区扇形支架组2例(14%)出现晚期内漏:1例Ib型在6个月,1例Ia型在12个月;开窗支架组(0区)无内漏。

关键数值与推荐

  • 扇形支架靶血管:左颈总动脉8例(1区),无名动脉1例(0区);5例开窗均用于保留无名动脉(0区)。

临床怎么用

  • 对于累及弓上分支的主动脉弓疾病,当解剖条件允许时,可考虑使用扇形或开窗定制支架在0区或1区行TEVAR以保留分支血流。
  • 术后需密切随访内漏,尤其1区扇形支架患者。

局限性

  • 样本量小(14例),为单中心回顾性研究,随访时间有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The aim of this study is to present midterm results of thoracic endovascular aortic repair (TEVAR) using scalloped or fenestrated custom-made endovascular grafts (CMEGs) in aortic arch Zones 0 and 1. METHODS: A retrospective review of prospectively collected data involving consecutive patients with aortic arch disease treated by scalloped or fenestrated Relay Plus stent grafts (Terumo Aortic, Sunrise, FL) landed in Zones 0 and 1. Patient demographics, operative details, clinical outcomes, and complications were analyzed. RESULTS: Between February 2014 and February 2020, 14 patients (9 male and 5 female) with a median age of 66 years (range 48-84) underwent scalloped or fenestrated TEVAR to preserve flow to the supra-aortic trunks (SATs). In 6 cases the landing zone was Zone 0 and in 8, Zone 1. Target vessels for the scallops were left common carotid artery in 8 cases (Zone 1) and innominate artery (IA) in 1 (Zone 0). All 5 fenestrations were designed to preserve the IA (Zone 0). Technical success was 100% with no endoleaks on completion angiography. One fatal perioperative stroke (7%) occurred in a patient with a fenestration for the IA and atherosclerotic plaques in the arch. During median follow-up of 37.5 (3-72) months, no other patient died, and all the target vessels and cervical revascularizations remained patent. There was no paraplegia, no retrograde dissection, and no other complication. Two patients (14%) with scallops in Zone 1 developed late endoleak: 1 type Ib at 6 months and 1 type Ia endoleak at 12 months. There were no endoleaks at all in the group of fenestrated endografts (Zone 0). CONCLUSIONS: When anatomy allows, endovascular treatment using scalloped or fenestrated CMEGs in Zones 0 and 1 is a feasible technique to treat patients with aortic arch disease involving the SATs.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Fernández-Alonso L, Fernández Alonso S, Martínez Aguilar E, et al. Fenestrated and Scalloped Endovascular Grafts in Zone 0 and Zone 1 for Aortic Arch Disease. Ann Vasc Surg. 2020. PMID: 32554200. doi:10.1016/j.avsg.2020.06.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。