文献速递主动脉疾病

开窗支架在复杂腹主动脉瘤腔内修复中的顺应性比较

Endograft Conformability in Fenestrated Endovascular Aneurysm Repair for Complex Abdominal Aortic Aneurysms.
PubMed 文献 · J Endovasc Ther · 2020-06-22

本研究回顾性分析了145例接受开窗腔内动脉瘤修复术的复杂腹主动脉瘤患者,比较Zenith Fenestrated(ZF)和Fenestrated Anaconda(FA)两种定制开窗支架对患者血管解剖的影响。结果显示两种支架均改变血管解剖,但FA支架在主动脉直径和左肾动脉时钟位置的变化上小于ZF,提示FA具有更高的顺应性。

要点

  • 两种定制开窗支架植入后均导致主动脉和靶血管解剖参数改变。
  • FA支架在主动脉直径和左肾动脉时钟位置的变化上小于ZF支架,提示顺应性更优。
  • 观察者间对测量变量的一致性良好。

核心结论

  • 两种定制开窗支架均改变血管解剖,FA支架比ZF支架具有更高的顺应性。

研究设计与样本

  • 回顾性筛选234例患者,最终纳入145例,其中ZF组110例(平均年龄72.4±7.1岁,94例男性),FA组35例(平均年龄72.3±7.3岁,30例男性)。

主要发现

  • ZF组术后腹腔干角度(p=0.012)、肠系膜上动脉角度(p=0.022)、左肾动脉角度(p<0.001)、右肾动脉角度(p<0.001)、肠系膜上动脉水平主动脉直径(p<0.001)以及左肾动脉(p<0.001)和右肾动脉(p<0.001)时钟位置均发生显著变化。
  • FA组术后左肾动脉角度(p=0.001)、右肾动脉角度(p<0.001)和肠系膜上动脉迂曲指数(p=0.044)发生显著变化。
  • 组间变化差异见于肠系膜上动脉和肾动脉水平的主动脉直径(两者p<0.001)以及左肾动脉时钟位置(p=0.019)。

临床怎么用

  • 对于复杂腹主动脉瘤患者,选择开窗支架时应考虑不同支架的顺应性差异,FA支架可能更适应解剖变化。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Purpose: To compare the impact of 2 commercially available custom-made fenestrated endografts on patient anatomy. Materials and Methods: The records of 234 patients who underwent fenestrated endovascular aneurysm repair for abdominal aortic aneurysm from March 2002 to July 2016 in 2 hospitals were screened to identify those who had pre- and postoperative computed tomography angiography assessments with a slice thickness of ≤2 mm. The search identified 145 patients for further analysis: 110 patients (mean age 72.4±7.1 years; 94 men) who had been treated with the Zenith Fenestrated (ZF) endograft and 35 patients (mean age 72.3±7.3 years; 30 men) treated with the Fenestrated Anaconda (FA) endograft. Measurements included aortic diameters at the level of the superior mesenteric artery (SMA) and renal arteries, target vessel angles, target vessel clock positions, and the target vessel tortuosity index. Variables were tested for inter- and intraobserver agreement. Results: There was a good agreement between observers in all tested variables. The native anatomy changed in both groups after endograft implantation. In the ZF group, changes were seen in the angles of the celiac artery (p=0.012), SMA (p=0.022), left renal artery (LRA) (p<0.001), and the right renal artery (RRA) (p<0.001); the aortic diameter at the SMA level (p<0.001); and the LRA (p<0.001) and RRA (p<0.001) clock positions. In the FA group, changes were seen in the angles of the LRA (p=0.001) and RRA (p<0.001) and in the SMA tortuosity index (p=0.044). Between group differences in changes were seen for the aortic diameters at the SMA and renal artery levels (p<0.001 for both) and the LRA clock position (p=0.019). Conclusion: Both custom-made fenestrated endografts altered vascular anatomy. The data suggest a higher conformability of the Fenestrated Anaconda endograft compared with the Zenith Fenestrated.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. de Niet A, Donselaar EJ, Holewijn S, et al. Endograft Conformability in Fenestrated Endovascular Aneurysm Repair for Complex Abdominal Aortic Aneurysms. J Endovasc Ther. 2020. PMID: 32567964. doi:10.1177/1526602820936185

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。