文献速递血液透析通路

WavelinQ EndoAVF系统的真实世界应用

Real-World Usage of the WavelinQ EndoAVF System.
PubMed 文献 · Ann Vasc Surg · 2020-05-15

BACKGROUND: Dependent on existing deep to superficial perforating venous branches, the WavelinQ EndoAVF System is a novel technique used to create an arteriovenous fistula (AVF) between ulnar or radial veins and concomitant arteries for dialysis access.…

要点

  • WavelinQ初始手术成功率高,但约四成患者需后续腔内干预促进成熟。
  • perioperative并发症25%,多为自限性,1例假性动脉瘤需手术修复。
  • 随访期48%透析患者成功使用EndoAVF,平均肱动脉流入量1,078 cc/min。

核心结论

  • WavelinQ系统初始手术成功率高,但相当比例患者需后续腔内手术辅助成熟。

主要发现

  • 初始瘘管创建成功率100%,平均手术时间120分钟,透视时间9.6分钟,造影剂用量52.2 mL。
  • 8/32(25%)患者发生围手术期并发症:3例血肿、3例造影剂外渗、1例血管痉挛自行缓解、1例假性动脉瘤需手术修复。
  • 13/32(41%)患者接受后续腔内干预促进成熟:9/32(28%)分支弹簧圈栓塞、5/32(16%)血管成形/支架、3/32(9%)通路血栓切除。
  • 4/32(13%)患者需后续外科干预:1例假性动脉瘤修复、1例瘘管修正、2例血栓移植物中 definitive AVF 创建。
  • 平均随访73天时总体通畅率88%(28/32),平均肱动脉流入量1,078 cc/min,平均头静脉流出量447 cc/min(18/32)。

临床怎么用

  • WavelinQ EndoAVF可作为透析通路的可选方案,但需预期较高比例的后续腔内再干预以促进成熟。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Dependent on existing deep to superficial perforating venous branches, the WavelinQ EndoAVF System is a novel technique used to create an arteriovenous fistula (AVF) between ulnar or radial veins and concomitant arteries for dialysis access. We sought to examine a single center's success rates and short-term follow-up using this device. METHODS: All consecutive patients undergoing placement of a WavelinQ AVF from October 2018 to July 2019 were included. Preoperative/intraoperative variables including demographics, preoperative/postoperative duplex ultrasonography, success rate of procedure, and subsequent endovascular/surgical procedures were obtained. Descriptive statistics and comparison of groups requiring subsequent intervention were performed. RESULTS: Thirty-five patients underwent placement of the WavelinQ AVF, with 32 (91%) patients having at least one documented follow-up. These patients were predominantly male (23/32, 72%) with an average age of 60.2 and 23 of 32 (72%) patients were on dialysis. Initial fistula creation success rate was 100%. Average procedural length was 120 min, fluoroscopy time 9.6 min, and contrast usage 52.2 mL. Eight of 32 (25%) patients had perioperative complications (3 hematomas, 3 contrast extravasations, 1 resolved vessel spasm all resolving spontaneously, and 1 pseudoaneurysm requiring surgical repair). Thirteen of 32 (41%) patients underwent subsequent endovascular interventions to assist with maturation [9/32 (28%) branch coiling, 5/32 (16%) angioplasty/stenting, and 3/32 (9%) access thrombectomy] and 4 of 32 (13%) patients required subsequent surgical interventions (1 pseudoaneurysm repair, 1 revision of fistula, and 2 definitive AVF creation in thrombosed grafts). The majority of accesses (30/32, 94%) were ulnar-ulnar fistulas and overall patency at average follow-up of 73 days was 88% (28/32) with average brachial artery inflow volume of 1,078 cc/min and average cephalic vein (18/32) outflow volume of 447 cc/min. Eleven of 23 (48%) patients on dialysis were successfully using the EndoAVF at follow-up. CONCLUSIONS: The WavelinQ AVF system has a high initial procedural success rate, although a significant portion of patients require subsequent endovascular procedures to aid in maturation. Further work on determining factors predictive of need for reintervention is necessary.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Zemela MS, Minami HR, Alvarez AC, et al. Real-World Usage of the WavelinQ EndoAVF System. Ann Vasc Surg. 2020. PMID: 32417285. doi:10.1016/j.avsg.2020.05.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。