文献速递主动脉疾病外周动脉疾病

氰基丙烯酸正丁酯瘤囊栓塞在急诊EVAR中的可行性与安全性

Feasibility and Safety of Sac Embolization Using N-Butyl Cyanoacrylate in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysms or Isolated Iliac Artery Aneurysms.
PubMed 文献 · J Endovasc Ther · 2020-05-21

本研究回顾性比较了破裂腹主动脉瘤或孤立性髂动脉瘤急诊EVAR中,使用NBCA进行瘤囊栓塞(22例)与单纯EVAR(7例)的可行性与安全性,发现两组技术均成功,NBCA组临床成功率95%对71%,死亡率5%对43%(p=0.034),提示NBCA瘤囊栓塞可行且安全。

要点

  • 急诊EVAR中NBCA瘤囊栓塞技术成功率高,无手术相关并发症。
  • NBCA组死亡率5%(1/22),对照组43%(3/7),差异有统计学意义(p=0.034)。
  • NBCA组II型内漏发生率19%(4/21),对照组无。

核心结论

  • 在破裂腹主动脉瘤和髂动脉瘤急诊EVAR中,使用NBCA进行瘤囊栓塞似乎是可行且安全的。

研究设计与样本

  • 回顾性对照研究,纳入2012年2月至2019年12月间44例破裂AAA或IAA患者中的29例接受EVAR者。
  • NBCA瘤囊栓塞组22例(中位年龄77.5岁,男18例),对照组7例(中位年龄88岁,男6例)。

主要发现

  • 所有EVAR和栓塞操作均成功。
  • NBCA组临床成功率95%(21/22),对照组71%(5/7),p=0.14。
  • 无手术相关并发症。
  • NBCA组II型内漏4/21(19%),对照组无。
  • NBCA组死亡1例(5%),对照组死亡3例(43%),p=0.034。

临床怎么用

  • 对于破裂腹主动脉瘤或髂动脉瘤行急诊EVAR时,可考虑辅助使用NBCA进行瘤囊栓塞以降低死亡率。

局限性

  • 样本量小(NBCA组22例,对照组7例),对照组年龄偏大,为非随机对照研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the feasibility and safety of sac embolization with N-butyl cyanoacrylate (NBCA) in emergency endovascular aneurysm repair (EVAR) for ruptured abdominal aortic aneurysm (AAA) and iliac artery aneurysm (IAA) in comparison to EVAR without sac embolization. MATERIALS AND METHODS: Between February 2012 and December 2019, among 44 consecutive patients with ruptured AAA or IAA, 29 underwent EVAR. Of these, 22 patients (median age 77.5 years; 18 men) had concomitant sac embolization using NBCA; the remaining 7 patients (median age 88 years; 6 men) underwent EVAR without sac embolization and form the control group. The technical success, clinical success (hemodynamic stabilization), procedure-related complications, and mortality were compared between the groups. RESULTS: All EVAR procedures and embolizations were successful. The clinical success rates in the NBCA and control groups were 95% (21/22) and 71% (5/7), respectively (p=0.14). There was no complication related to the procedure. Type II endoleak occurred in 4 of 21 patients (19%) in the NBCA group vs none of the control patients. One patient (5%) died in the NBCA group vs 3 (43%) in the controls (p=0.034). CONCLUSION: Sac embolization using NBCA in emergency EVAR appears to be feasible and safe for ruptured AAA and IAA.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Ohba S, Shimohira M, Hashizume T, et al. Feasibility and Safety of Sac Embolization Using N-Butyl Cyanoacrylate in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysms or Isolated Iliac Artery Aneurysms. J Endovasc Ther. 2020. PMID: 32436809. doi:10.1177/1526602820923954

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。