文献速递主动脉疾病

覆膜支架封闭假腔在B型主动脉夹层模型中恢复局部血流动力学

Endograft exclusion of the false lumen restores local hemodynamics in a model of type B aortic dissection.
PubMed 文献 · J Vasc Surg · 2020-01-01

本研究在硅胶主动脉夹层模型中置入胸主动脉覆膜支架,采用四维血流磁共振成像评估血流动力学。结果显示支架区假腔完全闭塞、真腔恢复抛物线血流,支架远端假腔形成低流速高反流盲袋,而更远端假腔仍保持通畅。提示仅覆盖主要破口可能不足以防止假腔持续通畅。

要点

  • 覆膜支架区假腔完全闭塞,真腔恢复抛物线血流。
  • 支架远端假腔形成低流速、高反流的促血栓盲袋。
  • 更远端自由假腔仍保持通畅,血流与未置入支架时相当。

核心结论

  • 覆膜支架置入改善了支架区真腔血流动力学,符合初始假设。
  • 支架远端假腔呈促血栓血流模式,但更远端自由假腔仍保持通畅。
  • 临床上提示仅覆盖主要破口可能不足以防止假腔经未覆盖的窗孔持续通畅。

研究设计与样本

  • 在具有顺应性和活动性内膜片的硅胶主动脉夹层模型中置入胸主动脉覆膜支架。
  • 模型安装于血流环路中,用定制正排量泵建立搏动性流体流。
  • 采用四维血流磁共振成像获取全流场,提取速度计算流量、反流指数和振荡剪切指数。

主要发现

  • 支架区假腔完全闭塞,真腔呈正常抛物线流型,最大流速30.4 ± 8.4 cm/s。
  • 支架远端假腔盲袋流速低(5.8 ± 2.7 cm/s),反流指数高(27.9% ± 13.9%)。
  • 远端自由假腔段最大流速约7.0 ± 2.1 cm/s,与未置入支架时相当。
  • 可视化研究显示自由假腔区存在前向血流及真腔至假腔的左旋涡。
  • 自由假腔区振荡剪切指数降低。

临床怎么用

  • 覆膜支架可恢复支架区真腔血流并封闭局部假腔。
  • 需关注支架远端假腔盲袋的促血栓血流模式。
  • 对于未覆盖的窗孔,可能需扩展腔内干预以防止假腔持续通畅。

局限性

  • 研究为硅胶模型体外实验,非人体在体研究。
  • 模型虽具有顺应性和活动性内膜片,但可能未完全反映真实解剖与生理。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Endovascular intervention in uncomplicated type B dissection has not been shown conclusively to confer benefit on patients. The hemodynamic effect of primary entry tear coverage is not known. Endovascular stent grafts were deployed in a model of aortic dissection with multiple fenestrations to study these effects. It is hypothesized that endograft deployment will lead to restoration of parabolic true lumen flow as well as elimination of false lumen flow and transluminal jets and vortices locally while maintaining distal false lumen canalization. METHODS: Thoracic stent grafts were placed in silicone models of aortic dissection with a compliant and mobile intimal flap and installed in a flow loop. Pulsatile fluid flow was established with a custom positive displacement pump, and the models were imaged by four-dimensional flow magnetic resonance imaging. Full flow fields were acquired in the models, and velocities were extracted to calculate flow rates, reverse flow indices, and oscillatory shear index, the last two of which are measures of stagnant and disturbed flows. RESULTS: Complete obliteration of the false lumen was achieved in grafted aorta, with normal parabolic flow profiles in the true lumen (maximal velocity, 30.4 ± 8.4 cm/s). A blind false lumen pouch was created distal to this with low-velocity (5.8 ± 2.7 cm/s) and highly reversed (27.9% ± 13.9% reverse flow index) flows. In distal free false lumen segments, flows were comparable to ungrafted conditions with maximal velocities on the order of 7.0 ± 2.1 cm/s. Visualization studies revealed forward flow in these regions with left-handed vortices from true to false lumen. Shear calculations in free false lumen regions demonstrated reduced oscillatory shear index. CONCLUSIONS: Per the initial hypothesis, endovascular grafting improved true lumen hemodynamics in the grafted region. Just distally, a prothrombotic flow regimen was noted in the false lumen, yet free false lumen distal to this remained canalized. Clinically, this suggests a need for advancing endovascular intervention beyond sole entry tear coverage to prevent further false lumen canalization through uncovered fenestrations.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Birjiniuk J, Oshinski JN, Ku DN, et al. Endograft exclusion of the false lumen restores local hemodynamics in a model of type B aortic dissection. J Vasc Surg. 2020. PMID: 32446515. doi:10.1016/j.jvs.2019.06.222

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。