Viabahn球囊扩张式支架与自膨式覆膜支架在分支型主动脉腔内修复中的性能比较
本研究前瞻性纳入263例复杂主动脉瘤患者,比较Viabahn球囊扩张式支架(VBX)与自膨式覆膜支架(SES)作为定向分支桥接支架的性能。共179个分支(VBX 96个,SES 81个),24个月一期通畅率、免于内漏、免于二次干预及分支不稳定性均无显著差异,无分支相关破裂或死亡。
要点
- VBX与SES作为分支桥接支架在24个月一期通畅率、内漏及再干预率上相似。
- 两组均无分支相关主动脉破裂或死亡,提示VBX安全有效。
- 结论需多中心大样本及更长随访验证。
核心结论
- 在高容量经验丰富的主动脉中心,VBX支架作为分支型腔内修复的桥接支架是安全有效的选择。
研究设计与样本
- 前瞻性医师发起的研究器械豁免试验,纳入2012年7月至2019年6月共263例复杂主动脉瘤患者。
- 共植入977根血管,其中分支179个(VBX 96个,SES 81个),中位年龄71岁,70%男性。
主要发现
- 24个月总体生存率78.5%,无分支相关破裂或死亡。
临床怎么用
- 在分支型腔内修复中,VBX可作为安全有效的桥接支架选项,尤其适用于经验丰富的中心。
局限性
- 单中心回顾性分析,样本量有限,随访时间较短,需多中心大样本研究验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The objective of this study was to compare the performance between the Viabahn balloon-expandable stent (VBX; Viabahn [W. L. Gore & Associates, Flagstaff, Ariz]) and a covered self-expandable stent (SES; Fluency [Bard Peripheral Vascular, Tempe, Ariz]) used as bridging stents for directional branches during fenestrated or branched endovascular aneurysm repair of complex aortic aneurysms. METHODS: Patients with thoracoabdominal aortic aneurysms (type I-IV) or pararenal aortic aneurysms either at high risk for open repair or unsuitable for endovascular repair with commercially available devices were prospectively enrolled in a physician-sponsored investigational device exemption trial. Descriptive statistics of the cohort included demographics, risk factors, and anatomic and device characteristics. Individual branches were grouped as either VBX or SES and had data analyzed for primary patency, branch-related type I or type III endoleaks, branch instability, branch-related secondary intervention, and branch-related aortic rupture or death. Categorical variables were expressed as total and percentage, and continuous variables were expressed as median (interquartile range). Kaplan-Meier curves were used to estimate long-term results. Groups were compared with the log-rank test. P value <.05 was considered statistically significant. RESULTS: During the period from July 2012 through June 2019, there were 263 patients treated for complex aortic aneurysm (thoracoabdominal aortic aneurysm) with fenestrated or branched endografts. The devices used were either custom-manufactured devices or off-the-shelf p-Branch or t-Branch (Cook Medical, Bloomington, Ind) devices. The median age was 71 years (interquartile range, 66-79 years); 70% were male, and 81% were white. The most common cardiac risk factors were smoking (92%), hypertension (91%), hyperlipidemia (78%), and chronic obstructive pulmonary disease (52%). The total number of vessels incorporated into the repair was 977, with branches representing 18.4% (179 branches). Among these 179 branches, the celiac artery, superior mesenteric artery, right renal artery, and left renal artery received 54 (30%), 56 (31%), 38 (21%), and 31 (18%) branches, respectively. VBX and SES groups represented 96 (54%) and 81 (46%) of the branches implanted. The celiac artery, superior mesenteric artery, right renal artery, and left renal artery received VBX as a bridging stent in 40%, 46.7%, 33.8%, and 32.2% respectively. The overall cohort survival rate was 78.5% at 24 months. There was no branch-related rupture or mortality. Primary patency at 24 months (VBX, 98.1%; SES, 98.6%; log-rank, P = .95), freedom from endoleak (VBX, 95.6%; SES, 98.6%; log-rank, P = .66), freedom from secondary intervention (VBX, 94.7%; SES, 98.1%; log-rank, P = .33), and freedom from branch instability (VBX, 95.6%; SES, 97.2%; log-rank, P = .77) were similar between groups. CONCLUSIONS: This initial experience with VBX stents demonstrated excellent primary patency and similarly low rates of branch-related complications and endoleaks, with no branch-related aortic rupture or death. Our results demonstrate that in a high-volume, experienced aortic center, the VBX stent is a safe and effective bridging stent option during branched endovascular aortic repair. Multicenter studies with a larger cohort and longer follow-up are necessary to validate these findings.
引用
- Motta F, Parodi FE, Knowles M, et al. Performance of Viabahn balloon-expandable stent compared with self-expandable covered stents for branched endovascular aortic repair. J Vasc Surg. 2020. PMID: 32473341. doi:10.1016/j.jvs.2020.05.028
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。