文献速递主动脉疾病慢性静脉疾病

腹主动脉瘤修复中需左侧下腔静脉间置重建的病例

Abdominal Aortic Aneurysm Repair Requiring Left-Sided Inferior Vena Cava Interposition.
PubMed 文献 · Ann Vasc Surg · 2020-05-19

本文报告一例56岁男性6.2厘米腹主动脉瘤患者,术前发现左侧下腔静脉。术中因下腔静脉横跨瘤颈阻碍动脉吻合,遂行下腔静脉切断、腹主动脉瘤修复及24毫米Dacron管间置重建下腔静脉,术后恢复顺利,3个月随访移植物通畅。结论指出左侧下腔静脉是腹主动脉手术中的罕见异常,切断重建是暴露不佳时的可行方案。

要点

  • 左侧下腔静脉是腹主动脉手术中的罕见先天性异常,可增加技术难度。
  • 当其他技术无法提供足够暴露时,可考虑切断下腔静脉并间置移植重建。
  • 本例术后恢复顺利,3个月随访移植物通畅。

核心结论

  • 左侧下腔静脉是腹主动脉手术中罕见的异常,若其他技术无法提供足够暴露,下腔静脉切断联合间置移植重建是可行解决方案。

研究设计与样本

  • 病例报告:56岁男性,非破裂性6.2厘米腹主动脉瘤,术前影像显示左侧下腔静脉,行择期开放修复。

主要发现

  • 术中发现下腔静脉在瘤颈处横跨,导致动脉吻合暴露不充分。
  • 切断下腔静脉后完成腹主动脉瘤修复,并用24毫米Dacron管间置重建下腔静脉。
  • 术后恢复顺利,3个月随访移植物通畅。

临床怎么用

  • 腹主动脉手术术前应识别左侧下腔静脉等静脉异常,以便规划手术策略。
  • 当左侧下腔静脉阻碍动脉吻合暴露时,可考虑切断下腔静脉并间置移植重建。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Left-sided inferior vena cava (IVC) is a rare congenital venous anomaly. We describe a case of open repair of a nonruptured abdominal aortic aneurysm (AAA) in a patient with left-sided inferior vena cava requiring IVC transection and reconstruction with interposition graft. CASE REPORT: A 56-year-old man presented for elective repair of a 6.2-cm AAA with preoperative imaging demonstrating a left-sided IVC. Intraoperatively, IVC crossing at the aneurysm neck conferred inadequate exposure for arterial anastomosis. After transection of the IVC, the AAA was repaired, and the IVC was reconstructed with a 24-mm Dacron tube graft. His recovery was uneventful, and grafts were patent at 3-month follow-up. CONCLUSIONS: Left-sided IVC is a rare anomaly encountered during abdominal aortic surgery that presents technical challenges. Division of the IVC and reconstruction with interposition graft is a possible solution if other techniques fail to provide adequate exposure.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Wu WK, Guth CM, Mulherin JL, et al. Abdominal Aortic Aneurysm Repair Requiring Left-Sided Inferior Vena Cava Interposition. Ann Vasc Surg. 2020. PMID: 32439518. doi:10.1016/j.avsg.2020.05.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。