CASPER支架颈动脉支架术后随访:双功能超声评估
单中心回顾性研究纳入101例CASPER双层颈动脉支架患者,术后12个月双功能超声显示中度支架内再狭窄(ISR)3例(2.8%)、重度ISR 2例(1.9%,含1例支架闭塞)。多数患者无症状,仅2例因ISR或闭塞后小卒中需再治疗,多变量回归未发现ISR相关因素。
要点
- CASPER支架术后12个月ISR发生率低,中度2.8%、重度1.9%
- 双功能超声是颈动脉支架术后随访和检出ISR的有效工具
- ISR相关因素未明确,需进一步研究验证
核心结论
- CASPER支架置入后12个月双功能超声评估的ISR发生率低,但需进一步研究。
研究设计与样本
- 单中心回顾性研究,纳入2014年1月至2017年6月连续101例接受CASPER支架治疗的颈内动脉狭窄患者(女性21.8%,中位年龄72.1岁)。
主要发现
- 12个月随访时,中度ISR(≥50%且<70%)3例(2.8%),重度ISR(≥70%)2例(1.9%,含1例支架闭塞)。
- 除上述2例重度ISR患者外,其余患者在随访期间无症状。
- 1例因ISR在小卒中后需再治疗,另1例支架闭塞也表现为小卒中。
- 多变量逻辑回归未发现与ISR显著相关的因素。
关键数值与推荐
- 支架置入适应症:症状性颈动脉狭窄≥70%直径(或≥50%直径伴溃疡),或无症状患者颈动脉分叉或颈内动脉近端狭窄≥80%。
- 双功能超声检查时间点:置入前、置入后24小时内、14天、3、6、12个月。
临床怎么用
- CASPER支架术后可采用双功能超声进行随访以评估ISR。
- ISR发生率低,多数患者无症状,但需关注重度ISR或闭塞相关症状。
局限性
- 单中心回顾性设计。
- 样本量有限(101例)。
- 未发现ISR相关因素,需进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To report results of duplex ultrasound evaluation of consecutive patients after carotid stenting with the double layer Carotid Artery Stent designed to Prevent Embolic Release (CASPER) stent system. METHODS: Between January 2014 and June 2017, a single-center, retrospective study of 101 consecutive patients (21.8% female; median age, 72.1 years) was performed. Patients with internal carotid artery stenosis treated with the CASPER stent were included. Eligibility criteria for stenting included stenosis of ≥70% of the vessel diameter (or ≥50% diameter with ulceration) in symptomatic carotid artery stenosis or ≥80% stenosis in asymptomatic patients at the carotid artery bifurcation or the proximal cervical internal carotid artery. Duplex ultrasound examination was performed before and within 24 hours of implantation as well as at 14 days, and 3, 6, and 12 months. RESULTS: At the 12-month follow-up visit, moderate in-stent restenosis (ISR) (≥50% and <70%) was detected in three stents (2.8%) and severe (≥70%) ISR in two (1.9%; including one case of stent occlusion). All but the two latter patients remained asymptomatic during the follow-up period. One patient required retreatment for ISR after a minor stroke and another patient with stent occlusion also re-presented with a minor stroke. Multivariable logistic regression was unable to detect any significant factors associated with ISR. CONCLUSIONS: Duplex ultrasound examination after carotid stenting is a useful tool for patient follow-up and determination of ISR. We found a low incidence of ISR assessed by duplex ultrasound examination at 12 months after CASPER stenting, but further studies are warranted.
引用
- Mutzenbach JS, Griessenauer CJ, Broussalis E, et al. Follow-up after carotid stenting with the CASPER stent system: A duplex ultrasound evaluation. J Vasc Surg. 2020. PMID: 32325231. doi:10.1016/j.jvs.2020.03.048
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。