文献速递外周动脉疾病

Gore Excluder髂分支内假体单独用于孤立性髂动脉瘤腔内修复的结局

Outcomes after Standalone Use of Gore Excluder Iliac Branch Endoprosthesis for Endovascular Repair of Isolated Iliac Artery Aneurysms.
PubMed 文献 · Ann Vasc Surg · 2020-03-28

本研究评估了单独使用Gore Excluder髂分支内假体(不联合主动脉支架)择期腔内修复孤立性髂动脉瘤的结局。共纳入11例连续患者(10例男性,中位年龄75岁),技术成功率100%,30天死亡率、主要不良事件和主要入路并发症均为0%。中位随访14个月,髂内动脉一期通畅率100%,无分支不稳定或移植物相关不良事件,结论认为该技术安全、可行且有效。

要点

  • 单独使用Gore Excluder IBE修复孤立性髂动脉瘤技术成功率100%。
  • 30天死亡、主要不良事件及主要入路并发症均为0%。
  • 中位随访14个月,髂内动脉一期通畅率100%,无移植物相关不良事件。

核心结论

  • 单独使用Gore Excluder IBE择期腔内修复孤立性髂动脉瘤安全、可行且有效,可能支持在解剖合适患者中作为有效腔内重建技术。

主要发现

  • 30天死亡率、主要不良事件和主要入路并发症均为0%。
  • 随访期间生存率91%,无主动脉相关死亡,仅记录1例非主动脉相关死亡。
  • 中位随访14个月,髂内动脉一期通畅率100%,髂内动脉分支不稳定0%,移植物相关不良事件0%。
  • 无移植物移位≥10 mm,无移植物相关二次干预;2例患者术后3个月需手术相关二次干预(1例股总动脉内膜剥脱术,1例髂外动脉支架置入)。
  • 无新发1型或3型内漏,1例出现新发2型内漏;6例(55%)瘤囊回缩≥5 mm,其余稳定;无新发臀部跛行。

临床怎么用

  • 对于解剖合适的孤立性髂动脉瘤患者,可考虑单独使用Gore Excluder IBE进行择期腔内修复。

局限性

  • 样本量小(11例),中位随访仅14个月,为单中心回顾性研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The aim of our study was to describe outcomes of stand-alone use (i.e., without concomitant implantation of an aortic stent graft) of the Gore Excluder iliac branch endoprosthesis (IBE) for elective endovascular repair of isolated iliac artery aneurysms. METHODS: We evaluated all consecutive patients electively treated for isolated iliac artery aneurysms using standalone Gore Excluder IBE (January 2014-December 2018). Early (i.e., 30-day) endpoints were technical success, mortality, major adverse events (MAEs), and major access-site complications. Late endpoints were survival, freedom from aortic-related mortality (ARM), internal iliac artery (IIA) primary patency, IIA branch instability, graft-related adverse events (GRAEs), secondary interventions, endoleaks (ELs), aneurysm sac behavior, and new-onset buttock claudication (BC). RESULTS: A total of 11 consecutive patients (10 men; median age 75 years) were included. The technical success rate was 100%. At 30 days, mortality, MAEs, and major access-site complications were all 0%. Survival and freedom from ARM were 91% and 100%, respectively; only one nonaortic related death was recorded during follow-up. At a median follow-up of 14 months, IIA primary patency, IIA branch instability, and GRAEs were 100%, 0%, and 0%, respectively. No instances of graft migration ≥10 mm were detected. No graft-related secondary interventions were recorded, and 2 patients required a procedure-related secondary intervention 3 months after the index procedure (1 common femoral artery endarterectomy and 1 external iliac artery stenting). Although new-onset type 1 or type 3 ELs were never noted, one patient developed a new-onset type 2 EL. Aneurysm sac regression ≥5 mm was noted in 6 patients (55%), whereas in the remaining ones, the sac size was stable. No instances of new-onset BC were noted. CONCLUSIONS: Use of standalone Gore Excluder IBE for elective endovascular repair of isolated iliac artery aneurysms is a safe, feasible, and effective treatment option. These results may support use of the technique as an effective means of endovascular reconstruction in patients with suitable anatomy.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. D'Oria M, Tenorio ER, Oderich GS, et al. Outcomes after Standalone Use of Gore Excluder Iliac Branch Endoprosthesis for Endovascular Repair of Isolated Iliac Artery Aneurysms. Ann Vasc Surg. 2020. PMID: 32234400. doi:10.1016/j.avsg.2020.03.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。