文献速递外周动脉疾病

切割球囊对股腘动脉病变经皮腔内血管成形术结局的影响

Impact of Scoring Balloons on Percutaneous Transluminal Angioplasty Outcomes in Femoropopliteal Lesions.
PubMed 文献 · J Endovasc Ther · 2020-04-06

该研究回顾性分析2013至2019年398例股腘动脉原发病变行PTA的患者,经倾向性评分匹配后比较切割球囊与普通球囊各84例。切割球囊组残余狭窄<30%比例更高、严重夹层更少、临时支架率更低,且PACSS 0-3病变18个月一期通畅率更优。

要点

  • 切割球囊提高股腘动脉PTA即刻成功率并减少严重夹层。
  • 切割球囊降低临时支架植入率。
  • PACSS 0-3病变中切割球囊与18个月一期通畅率更优相关。

核心结论

  • 切割球囊可能有效恢复股腘动脉病变的急性管腔获得并预防严重动脉夹层。
  • 切割球囊可能与PACSS 0-3病变18个月一期通畅率更优相关。

研究设计与样本

  • 回顾性研究,2013至2019年连续398例股腘动脉原发病变行PTA。
  • 经1:1倾向性评分匹配后,切割球囊组84例(平均年龄73.4±8.3岁,65例男性),普通球囊组84例(平均年龄75.6±8.7岁,56例男性)。
  • 匹配变量包括血液透析、TASC II分类、PACSS分级、病变长度和血管内超声使用。

主要发现

  • 切割球囊组残余狭窄<30%比例高于普通球囊组(77.4% vs 57.1%,p=0.005)。
  • 切割球囊组严重动脉夹层发生率低于普通球囊组(16.7% vs 29.8%,p=0.043)。
  • 切割球囊组临时支架植入率显著低于普通球囊组(13.3% vs 29.8%,p=0.008)。
  • 多变量分析显示切割球囊使用(p<0.001)和延长扩张时间(p<0.001)是成功血管成形术的独立预测因素,慢性完全闭塞(p=0.005)和更长病变长度(p=0.005)是不成功手术的预测因素。
  • 匹配人群中108例PACSS 0-3病变的Kaplan-Meier分析显示,意向性治疗分析中切割球囊组18个月一期通畅率更优[68.6%(95%CI 53.5%至80.6%)vs 43.0%(95%CI 28.7%至58.5%),p=0.044]。

临床怎么用

  • 在股腘动脉原发病变PTA中,可考虑使用切割球囊以提高即刻管腔获得并减少严重夹层。
  • 对PACSS 0-3病变,切割球囊可能改善18个月一期通畅率。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Purpose: To investigate the efficacy of scoring balloons for immediate success of percutaneous transluminal angioplasty (PTA) in femoropopliteal lesions. Materials and Methods: Between 2013 and 2019, 398 consecutive patients with de novo femoropopliteal lesions were treated using PTA in our hospital. The procedure success rate was compared among patients undergoing PTA with vs without scoring balloons after 1:1 propensity score matching on hemodialysis, TransAtlantic Inter-Society Consensus II classification, Peripheral Arterial Calcium Scoring System (PACSS) grade, lesion length, and use of intravascular ultrasound. Propensity matching produced 84 patients (mean age 73.4±8.3; 65 men) treated with scoring balloons and 84 patients (mean age 75.6±8.7; 56 men) treated with plain balloons. Kaplan-Meier analysis investigated patency after the procedure in both groups; estimates are given with the 95% confidence interval (CI). Results: Residual stenosis <30% was achieved more often (77.4% vs 57.1%, p=0.005) and severe arterial dissection occurred less frequently (16.7% vs 29.8%, p=0.043) in the scoring balloon group vs the plain balloon group, respectively. The rate of provisional stenting was significantly lower after scoring balloon use (13.3% vs 29.8%, p=0.008). Multivariable analysis revealed that use of scoring balloons (p<0.001) and prolonged inflation time (p<0.001) were independent predictors of successful angioplasty, whereas chronic total occlusion (p=0.005) and longer lesion length (p=0.005) were predictors of an unsuccessful procedure. Among 108 patients with PACSS 0-3 lesions in the matched population, Kaplan-Meier analysis showed better primary patency at 18 months in the scoring balloon group in the intention to treat analysis [68.6% (95% CI 53.5% to 80.6%) vs 43.0% (95% CI 28.7% to 58.5%), p=0.044]. Conclusion: Scoring balloons may be effective in restoring acute lumen gain and preventing severe arterial dissection in femoropopliteal lesions. Moreover, scoring balloons might be associated with better primary patency at 18 months in PACSS 0-3 lesions.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Horie K, Tanaka A, Taguri M, et al. Impact of Scoring Balloons on Percutaneous Transluminal Angioplasty Outcomes in Femoropopliteal Lesions. J Endovasc Ther. 2020. PMID: 32249658. doi:10.1177/1526602820914618

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。