孤立性髂内动脉瘤的治疗管理
该回顾性研究纳入42例孤立性髂内动脉瘤患者,比较开放手术与不同腔内技术的结果。联合弹簧圈栓塞与覆膜支架置入在腔内方法中内漏和再干预率最低,30天总死亡率为5%,破裂者达17%。
要点
- 联合弹簧圈栓塞与支架置入在腔内方法中内漏和再干预率最低
- 开放手术手术时间和住院时间最长
- 破裂性孤立性髂内动脉瘤30天死亡率为17%
核心结论
- 对于无足够瘤颈的大孤立性髂内动脉瘤,弹簧圈栓塞联合覆膜支架置入是可行、安全且有效的治疗方式。
研究设计与样本
- 回顾性研究,纳入2009年1月至2019年3月两家医院的42例孤立性髂内动脉瘤患者,共治疗43个动脉瘤;平均年龄71岁,男性37例、女性5例。
主要发现
- 手术方式包括手术切除6例、腔内弹簧圈栓塞12例、跨髂内动脉开口覆膜支架置入8例(9个动脉瘤)、联合弹簧圈栓塞与支架置入16例。
- 即刻技术成功率分别为栓塞67%、支架置入67%、联合方法88%。
- 全组30天死亡率为5%,破裂性孤立性髂内动脉瘤患者为17%。
- 存活40例中7例(18%)出现臀部跛行;中位随访56个月。
临床怎么用
- 对于无足够瘤颈的大孤立性髂内动脉瘤,可优先考虑弹簧圈栓塞联合覆膜支架置入的腔内治疗。
- 开放手术手术时间和住院时间较长,选择术式时需综合评估。
- 破裂性孤立性髂内动脉瘤30天死亡率较高,需积极救治。
局限性
- 回顾性研究,样本量较小(42例),来自两家医院。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Isolated internal iliac artery aneurysms (IIIAAs) are rare, life-threatening entities for which the optimal treatment strategy has not been established. This study aimed to evaluate the outcomes of open and endovascular treatment of IIIAAs. METHODS: IIIAA cases between January 2009 and March 2019 at two hospitals were retrospectively reviewed. Demographic, clinical, ancillary testing, treatment, and outcome data were collected and analyzed. RESULTS: Forty-two patients (37 men and 5 women) with a mean age of 71 years were included. Twenty-five patients (60%) had a history of hypertension. Twenty-two patients (52%) were asymptomatic, and 16 (38%) presented with abdominal pain (12 with ruptured aneurysms). The 42 included patients had 43 treated IIIAAs. The following surgical techniques were used: surgical resection (n = 6), endovascular coil embolization (n = 12), endovascular stent graft placement across the internal iliac artery origin (n = 8 with 9 aneurysms), and combined coil embolization and stent graft placement (n = 16). The immediate technical success rate was 67%, 67%, and 88% for embolization, stent graft placement, and combined method, respectively. Open surgery was associated with the longest operative time and hospital stay. Overall 30-day mortality was 5% for all patients and 17% for patients with ruptured IIIAAs. Buttock claudication occurred in 7 of 40 patients who survived (18%). The median follow-up time was 56 months. The combined approach was associated with the lowest rates of endoleak (6% vs 25% and 29%) and reintervention (6% vs 17% and 29%) of the three endovascular methods. CONCLUSIONS: Endovascular coil embolization with stent graft placement is a feasible, safe, and effective treatment approach for large IIIAAs without adequate aneurysm necks.
引用
- Yang M, Li L, Liu Y, et al. Therapeutic management of isolated internal iliac artery aneurysms. J Vasc Surg. 2020. PMID: 32276024. doi:10.1016/j.jvs.2020.02.038
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。