开窗腔内修复术后内脏分支支架喇叭口几何变化评估新方法的验证
本研究回顾性分析10例开窗腔内修复术(fEVAR)患者共31枚分支支架(BSG)的系列CT血管造影,验证一种基于中心线重建和标记点坐标评估喇叭口几何变化的新方法。结果显示BSG直径和喇叭口至开窗距离的观察者间一致性极佳(ICC 0.865和0.944),6例患者出现BSG相关并发症,其中5枚并发症BSG的D-ratio较术后首次CTA有明显变化。
要点
- 新方法可精确评估fEVAR内脏分支支架的喇叭口几何,观察者间一致性极佳。
- 6例患者随访出现BSG相关并发症(2例IIIc型内漏、4例BSG闭塞)。
- 6枚并发症BSG中5枚的D-ratio较术后首次CTA有明显变化。
核心结论
- 精确评估fEVAR内脏BSG几何形态可行,可检测可能先于后期并发症的几何变化,有助于定位起源,但需更大样本明确临床价值。
研究设计与样本
- 回顾性分析10例fEVAR患者(31枚BSG)的系列CTA,随访至少2年,通过FSG和每枚BSG的中心线重建,基于标记点坐标和主动脉腔网格重建喇叭口几何。
主要发现
- BSG直径和喇叭口至开窗距离计算的观察者间一致性极佳(ICC 0.865和0.944;RC 2.2%和4.5%)。
- 随访期间6例患者出现BSG相关并发症:2例IIIc型内漏和4例BSG闭塞。
- 6枚并发症BSG中5枚的D-ratio较术后首次CTA有明显变化。
关键数值与推荐
- 喇叭口至开窗距离为喇叭口圆周顶部至FSG织物的最短距离。
- 喇叭口程度用喇叭口与开窗直径比及BSG压缩直径比(D-ratio)评估。
临床怎么用
- 该方法可用于fEVAR术后BSG几何的精确评估,检测可能先于后期并发症的几何变化,辅助定位起源。
局限性
- 样本量小(10例患者31枚BSG),需更大系列患者明确其真正临床价值。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Purpose: To validate a novel method to evaluate changes in the geometry of renovisceral bridging stent-grafts (BSGs) in patients undergoing fenestrated endovascular aneurysm repair (fEVAR). Materials and Methods: Retrospective analysis was conducted of serial computed tomography angiograms (CTAs) of 10 fEVAR patients (31 BSGs) with at least 2 years of CTA follow-up. Centerline reconstructions were made through the fenestrated stent-graft (FSG) and each BSG. Flare geometry was reconstructed based on marker coordinates and a mesh of the aortic lumen. The shortest distance was calculated from the top of the flare circumference to the FSG fabric. The amount of flaring was assessed with the flare to fenestration diameter ratio and BSG compression to diameter ratio (D-ratio). All measurements were performed by 2 observers. Interobserver variability was assessed; results are presented as the intraclass correlation coefficient (ICC) and repeatability coefficient (RC). Results: Excellent interobserver agreement was achieved for BSG diameter and flare to fenestration distance calculations (ICC 0.865 and 0.944; RC 2.2% and 4.5%, respectively). Six patients had BSG-related complications during follow-up: 2 type IIIc endoleaks and 4 BSG occlusions. Five of the 6 BSGs with complications showed a considerable change in the D-ratio compared with the first postoperative CTA. Conclusion: Precise assessment of the geometry of visceral BSGs in fEVAR is feasible with the presented method. Geometrical changes that may precede later complications can be detected, which could aid in localization of the origin, but a larger series of patients is necessary to define its true clinical merit.
引用
- Overeem S, Schuurmann R, Schumacher M, et al. Validation of a Novel Methodology to Evaluate Changes in the Flare Geometry of Renovisceral Bridging Stent-Grafts After Fenestrated Endovascular Aneurysm Repair. J Endovasc Ther. 2020. PMID: 32314657. doi:10.1177/1526602820915932
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。