文献速递主动脉疾病

Nellix内假体无并发症EVAS术后FDG-PET/CT的生理性表现

Physiological Appearance of Hybrid FDG-Positron Emission Tomography/Computed Tomography Imaging Following Uncomplicated Endovascular Aneurysm Sealing Using the Nellix Endoprosthesis.
PubMed 文献 · J Endovasc Ther · 2020-04-15

前瞻性纳入8例择期行Nellix EVAS的男性患者,术前及术后6周行FDG-PET/CT,分析腹主动脉四个区域。视觉评估示FDG摄取均匀且术前术后无差异;肾上区SUV与TBR无显著变化,肾下颈区SUV显著下降而TBR无显著下降,瘤囊及髂区SUV与TBR均显著下降。结论为EVAS术后生理性FDG摄取稳定或较术前降低。

要点

  • 无并发症EVAS术后6周FDG摄取均匀,视觉评估与术前无差异。
  • 肾下颈区SUV显著下降,瘤囊及髂区SUV与TBR均显著下降。
  • 肾上区SUV与TBR术前术后无显著差异。

核心结论

  • 无并发症EVAS术后生理性FDG摄取较术前稳定或降低。

研究设计与样本

  • 前瞻性研究纳入8例连续男性患者(中位年龄78岁),择期行EVAS,注册号NCT02349100。
  • 所有患者术前及EVAS术后6周行FDG-PET/CT,分析腹主动脉肾上、肾下颈、瘤囊及髂四个区域。

主要发现

  • 视觉评估示术前术后FDG摄取均匀且无差异。
  • 肾上区SUV与TBR术前术后无显著差异。
  • 肾下颈区SUV显著下降,TBR无显著下降。
  • 瘤囊及髂区SUV与TBR均显著下降。

临床怎么用

  • 无并发症EVAS术后FDG摄取稳定或降低,解读PET/CT时需考虑此生理模式以鉴别移植物感染与植入后综合征。

局限性

  • 样本量小(8例),仅纳入男性。
  • FDG-PET/CT检测EVAS术后内移植物感染的适用性及截断值尚需未来研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Purpose: To investigate the physiological uptake of hybrid fluorine-18-fluorodeoxyglucose (FDG)-positron emission tomography/computed tomography (PET/CT) before and after an uncomplicated endovascular aneurysm sealing (EVAS) procedure as a possible tool to diagnose EVAS graft infection and differentiate from postimplantation syndrome. Materials and Methods: Eight consecutive male patients (median age 78 years) scheduled for elective EVAS were included in the prospective study (ClinicalTrials.gov identifier NCT02349100). FDG-PET/CT scans were performed in all patients before the procedure and 6 weeks after EVAS. The abdominal aorta was analyzed in 4 regions: suprarenal, infrarenal neck, aneurysm sac, and iliac. The following parameters were obtained for each region: standard uptake value (SUV), tissue to background ratio (TBR), and visual examination of FDG uptake to ascertain its distribution. Demographic data were obtained from medical files and scored based on reporting standards. Results: Visual examination showed no difference between pre- and postprocedure FDG uptake, which was homogenous. In the suprarenal region no significant pre- and postprocedure differences were observed for the SUV and TBR parameters. The infrarenal neck region showed a significant decrease in the SUV and no significant decrease in the TBR. The aneurysm sac and iliac regions both showed a significant decrease in SUV and TBR between the pre- and postprocedure scans. Conclusion: Physiological FDG uptake after EVAS was stable or decreased with regard to the preprocedure measurements. Future research is needed to assess the applicability and cutoff values of FDG-PET/CT scanning to detect endograft infection after EVAS.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Groot Jebbink E, van Den Ham LH, van Woudenberg BBJ, et al. Physiological Appearance of Hybrid FDG-Positron Emission Tomography/Computed Tomography Imaging Following Uncomplicated Endovascular Aneurysm Sealing Using the Nellix Endoprosthesis. J Endovasc Ther. 2020. PMID: 32295455. doi:10.1177/1526602820913888

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。