移动C臂与杂交手术室在开窗支架腔内腹主动脉瘤修复中的影像学比较
单中心回顾性分析2006年1月至2016年7月连续96例接受开窗支架腔内修复(f-EVAR)的短颈、近肾及肾上主动脉瘤患者,比较杂交手术室(50例)与移动C臂(46例)的影像引导效果。两组技术成功率与1年生存无显著差异,杂交手术室组使用更复杂支架但造影剂用量显著更少。
要点
- 杂交手术室组技术成功率94%,移动C臂组91.3%,差异无统计学意义(P=0.72)。
- 杂交手术室组造影剂中位用量100 mL,显著少于移动C臂组的150 mL(P<0.001)。
- 移动C臂组靶内脏血管一期通畅率在6个月和12个月均显著更高。
核心结论
- 杂交手术室与移动C臂在f-EVAR术后即刻及1年结局相当,尽管杂交手术室组使用了显著更复杂的支架。
- 杂交手术室可能有助于在复杂f-EVAR中取得满意结果。
研究设计与样本
- 单中心回顾性分析前瞻性收集的连续病例数据。
- 2006年1月至2016年7月共96例短颈、近肾及肾上主动脉瘤患者接受f-EVAR,移动C臂组46例(48%),杂交手术室组50例(52%)。
- 主要终点为技术成功和围手术期并发症,次要终点包括30天和1年死亡率及靶血管通畅率。
主要发现
- 总体技术成功率为92.7%,移动C臂组91.3%,杂交手术室组94%(P=0.72)。
- 杂交手术室组复杂干预显著更多(38/50 vs. 14/46,P<0.001),移动C臂组以肾动脉f-EVAR为主。
- 杂交手术室组造影剂中位用量显著更少(100 mL vs. 150 mL,P<0.001)。
- 30天死亡率移动C臂组9%,杂交手术室组2%(P=0.14),1年生存率两组无显著差异。
- 靶内脏血管一期通畅率移动C臂组在6个月(87.6% vs. 85.5%,P=0.006)和12个月(83.8% vs. 78.3%,P=0.03)均显著更高;肾动脉一期通畅率在6个月和12个月无显著差异。
临床怎么用
- 在复杂f-EVAR中可考虑使用杂交手术室以辅助获得满意结果并减少造影剂用量。
- 移动C臂组靶内脏血管一期通畅率更高,选择影像平台时需结合病例复杂度和随访通畅性综合评估。
局限性
- 单中心回顾性研究,样本量有限(96例)。
- 两组基线复杂程度存在显著差异,杂交手术室组复杂干预更多,可能影响结局比较。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: To evaluate the advantages of a hybrid operating room (OR) (group 2) compared with a fluoroscopic mobile C-arm (group 1) during fenestrated stent-graft endovascular aneurysm repair (f-EVAR). METHODS: This single-center study retrospectively analyzed prospectively collected data of consecutive patients treated with f-EVAR for short-necked, juxtarenal, and suprarenal aortic aneurysms between January 2006 and July 2016. Primary end points were technical success and perioperative complications. Secondary end points included 30-day and 1-year mortality as well as target vessel patency. RESULTS: About 96 patients were treated (85 men; 74.1 ± 6.3 years); 46 patients (48%) belonging to group 1 and 50 (52%) patients belonging to group 2. Technical success was achieved in 92.7% of the procedures (group 1 91.3% vs. group 2 94%, P = 0.72). Significantly more complex interventions were performed in group 2 (n = 38 of 50) compared with group 1 (n = 14 of 46; P < 0.001), in which primarily renal f-EVAR interventions were performed. In group 2, significantly less contrast was used (median 150 mL vs. 100 mL; P < 0.001). The 30-day mortality in group 1 was 9% and 2% in group 2 (P = 0.14), and 1-year survival was also not significantly different between both groups. Target visceral vessel primary patency was significantly higher in group 1 (87.6% vs. 85.5% [P = 0.006] and 83.8% vs. 78.3% [P = 0.03]) at 6 and 12 months, respectively). There was no significant difference in renal artery primary patency at 6 and 12 months. CONCLUSIONS: Immediate and 1-year outcomes after f-EVAR for abdominal aortic aneurysm were comparable using a hybrid OR compared with a mobile C-arm, despite the use of significantly more complex stent grafts in the patients treated in the hybrid OR. The use of a hybrid OR may assist in achieving satisfying results in complex f-EVAR.
引用
- Yazar O, Mees BME, Provoost AL, et al. Comparing Mobile C-Arm with a Hybrid Operating Room for Imaging in Fenestrated Stent-Graft Endovascular Abdominal Aortic Aneurysm Repair. Ann Vasc Surg. 2020. PMID: 32283306. doi:10.1016/j.avsg.2020.04.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。