文献速递主动脉疾病

PET/CT与增强CT对疑似感染性主动脉瘤的诊断准确性

Diagnostic Accuracy of PET/CT and Contrast Enhanced CT in Patients With Suspected Infected Aortic Aneurysms.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2020-04-25

本研究评估了18F-FDG PET/CT和增强CT在疑似感染性主动脉瘤患者中的诊断准确性,采用四点评分和SUVmax定量分析,参考标准为临床表现、实验室和影像学综合。34例患者中13例确诊感染,PET/CT灵敏度高但特异性有限,诊断准确性高于增强CT。

要点

  • PET/CT对感染性主动脉瘤的灵敏度达85%-100%,阴性预测值88%-100%。
  • PET/CT特异性71%左右,假阳性是主要局限。
  • 增强CT灵敏度63%-88%,特异性50%-75%,准确性低于PET/CT。

核心结论

  • PET/CT检测感染性主动脉瘤的诊断准确性高,且高于增强CT。
  • PET/CT灵敏度极好,但特异性受假阳性影响。

研究设计与样本

  • 前瞻性纳入10例、回顾性纳入24例临床疑似感染性主动脉瘤患者,共34例。
  • 16例(47%)在抗菌治疗开始前,全部34例在血管干预前完成PET/CT,20例(59%)可行时加做增强CT。
  • 由两名独立读者采用四点评分评估两种影像,计算SUVmax,参考标准为临床表现、实验室和影像学综合。

主要发现

  • 34例中13例(38%)确诊感染性主动脉瘤,所有确诊者PET/CT均有代谢活性,中位SUVmax为6.6(四分位距4.7-21.8)。
  • 读者1:PET/CT灵敏度100%、特异性71%、阳性预测值68%、阴性预测值100%、准确性82%。
  • 读者1:增强CT灵敏度63%、特异性75%、阳性预测值63%、阴性预测值75%、准确性70%。
  • 读者2:PET/CT灵敏度85%、特异性71%、阳性预测值65%、阴性预测值88%、准确性77%。
  • 读者2:增强CT灵敏度88%、特异性50%、阳性预测值54%、阴性预测值86%、准确性65%。

临床怎么用

  • 对临床疑似感染性主动脉瘤患者,PET/CT可作为高灵敏度影像手段,阴性结果有助于排除感染。
  • 需警惕PET/CT假阳性,应结合临床和实验室结果综合判断。

局限性

  • 样本量小(共34例,确诊13例),部分为回顾性纳入。
  • 增强CT仅在20例(59%)患者中完成,两种影像比较可能受选择偏倚影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Infected aortic aneurysms are highly lethal, and management is very demanding, requiring an early diagnosis. The aim of this study was to evaluate the diagnostic accuracy of positron emission tomography/computed tomography with 18F-fluorodeoxyglucose (PET/CT) and contrast enhanced CT (CE-CT) in patients with suspected infected aortic aneurysms. METHODS: PET/CT was performed in patients with clinically suspected infected aortic aneurysms, and additional CE-CT was performed if feasible. Diagnostic accuracy was assessed by two independent readers using a four point grading score for both imaging modalities. Maximum standardised uptake values (SUVmax) were calculated for quantitative measurements of metabolic activity in PET/CT. The reference standard was a combination of clinical presentation, laboratory findings, and imaging. RESULTS: Ten patients were included prospectively in the study, 24 retrospectively; 16 patients (47%) prior to the start of antimicrobial treatment and all 34 patients prior to any vascular intervention. Thirteen of the 34 patients had an infected aortic aneurysm (38%). Proven infected aortic aneurysms were all metabolically active on PET/CT with a median SUVmax of 6.6 (interquartile range 4.7-21.8). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of PET/CT for the diagnosis of infected aortic aneurysm was 100%, 71%, 68%, 100%, and 82%, for reader 1 and 85%, 71%, 65%, 88%, and 77%, for reader 2. Respective values for CE-CT, performed in 20 patients (59%), were 63%, 75%, 63%, 75%, and 70%, for reader 1 and 88%, 50%, 54%, 86%, and 65%, for reader 2. CONCLUSION: The diagnostic accuracy of PET/CT in the detection of infected aortic aneurysms (n = 13) is high, and higher than CE-CT. While PET/CT demonstrates an excellent sensitivity, its specificity is hampered because of false positive findings.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. Husmann L, Huellner MW, Ledergerber B, et al. Diagnostic Accuracy of PET/CT and Contrast Enhanced CT in Patients With Suspected Infected Aortic Aneurysms. Eur J Vasc Endovasc Surg. 2020. PMID: 32340877. doi:10.1016/j.ejvs.2020.01.032

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。