文献速递主动脉疾病内脏/肾动脉与血管畸形

开窗支架近端锚定区最大化:移植物构型演变

Maximizing proximal seal zone in fenestrated endografting: Evolution in the approach to graft configuration.
PubMed 文献 · J Vasc Surg · 2020-04-21

回顾性分析两中心2012–2019年连续100例定制开窗支架(ZFEN)设计,比较两种近端构型。术后13%出现IA型内漏,随访均自行消退,无SMA受累。

要点

  • 构型B可较构型A平均多获得5.8 mm近端锚定区。
  • 术后IA型内漏13%,随访均消退,无SMA受累。

核心结论

  • 采用SMA大窗+双肾动脉小窗的ZFEN构型可显著延长近端锚定区,可能降低近端内漏风险。

研究设计与样本

  • 回顾性队列研究,分析两大学中心2012–2019年连续100例定制ZFEN移植物设计。
  • 近端锚定长度从术前CTA测量,从移植物顶端至动脉瘤起始处。

主要发现

  • 最常见构型为B(n=45)和A(n=38)。
  • 本可选A但选B时,锚定区平均增加5.8±2.8 mm;本可选B但选A时,平均损失5.8±1.9 mm。
  • 95例完成手术和随访者中,完成造影时IA型内漏12例(13%),随访均无需干预消退。
  • 构型B中无SMA因大窗错位而受累。

临床怎么用

  • 在制造条件允许时,优先考虑SMA大窗+双肾动脉小窗构型以最大化近端锚定区。
  • 该构型无需为预防SMA遮挡而置入支架,可简化操作。

局限性

  • 回顾性设计,样本量有限(100例设计,95例完成随访)。
  • 仅反映两中心经验,外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Fenestrated endografting for juxtarenal and pararenal abdominal aortic aneurysms affords the ability to seal stent grafts in normal aorta at and above the renal arteries. The Zenith fenestrated graft (ZFEN; Cook Medical, Bloomington, Ind) is custom-made to surgeon specifications, subject to certain manufacturing limitations. The most common configuration in the pivotal trial and in commercial use after approval has been as a scallop for the superior mesenteric artery (SMA) and two small fenestrations for the renal arteries (configuration A). An alternative configuration to maximize the seal zone length, consisting of a large fenestration for the SMA and two small fenestrations for the renal arteries (configuration B) has been routinely adopted at our institutions to potentially prevent type IA endoleak. METHODS: The present retrospective cohort study examined 100 consecutive ZFEN grafts designed for patients at two university centers from 2012 through 2019. The proximal seal length, measured from the top of the graft to the beginning of the aneurysm, was determined from the preoperative computed tomography angiograms. Alternative configurations were evaluated to determine whether they would have provided a longer proximal seal length. RESULTS: The two most common configurations were B (n = 45) and A (n = 38). For the cases in which A had been chosen but B could have been built, 5.8 ± 1.9 mm of seal zone length was lost. For the cases in which B was chosen but A could have been built, 5.8 ± 2.8 mm of seal zone length was gained. Owing, in part, to the increased proximal seal length with configuration B, this configuration has been used more frequently in the past 4 years of the present study compared with the first four (53% vs 25%; P = .004). Of 95 patients who had completed surgery and follow-up, type IA endoleaks were observed in 12 (13%) on completion angiography, all of which had resolved on follow-up imaging without intervention. No SMA was compromised by misalignment of the large fenestration in configuration B. CONCLUSIONS: A significantly longer proximal seal length can be obtained using a ZFEN with a large fenestration for the SMA and two small fenestrations for the renal arteries. Whenever possible, surgeons should consider this configuration to maximize the proximal seal length and potentially reduce the risk of proximal endoleak. An additional advantage of this approach is that stenting of the SMA to prevent shuttering will be unnecessary or impossible, making the procedure more technically facile.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Newton DH, Etkin Y, Foley PJ, et al. Maximizing proximal seal zone in fenestrated endografting: Evolution in the approach to graft configuration. J Vasc Surg. 2020. PMID: 32330599. doi:10.1016/j.jvs.2020.03.049

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。