文献速递主动脉疾病

开窗支架主动脉修复术后靶血管解剖变化的中期结果

Changes in Target Vessel Anatomy Following Fenestrated Endovascular Aneurysm Repair: Midterm Results.
PubMed 文献 · J Endovasc Ther · 2020-04-22

单中心回顾性研究分析56例开窗支架主动脉修复(fEVAR)患者,使用定制支架(22例Zenith,34例Anaconda),以Advanta V12(74,53%)和BeGraft(66,47%)桥接140条靶血管。中位随访24个月,发现V12与BeGraft在靶血管解剖变化上无差异,两种桥接支架均随时间适应靶血管解剖,且中度解剖变化似乎耐受而不增加靶血管并发症风险。

要点

  • V12与BeGraft桥接支架在中期随访中对靶血管解剖变化的影响无差异。
  • 桥接支架曲线长度比随时间显著增加(p<0.001),但两种支架间无差异。
  • 仅桥接支架外侧曲线长度与靶血管并发症显著相关(p=0.033)。

核心结论

  • V12与BeGraft桥接支架在fEVAR术后中期随访中靶血管解剖变化无差异。
  • 两种桥接支架均随时间适应靶血管解剖,中度解剖变化似乎耐受且不增加靶血管并发症风险。
  • 主体支架类型也影响靶血管解剖。

研究设计与样本

  • 回顾性单中心研究分析56例fEVAR患者(平均年龄71±7岁,49例男性)。
  • 使用定制支架:22例Zenith和34例Anaconda。
  • 桥接支架:Advanta V12(74,53%)和BeGraft(66,47%),共140条靶血管。

主要发现

  • 共分析393次测量(38腹腔干、102肠系膜上动脉、121左肾动脉、132右肾动脉)。
  • Zenith主体支架植入后桥接支架外侧/内侧曲线长度比较Anaconda更大(p<0.001)。
  • 桥接支架远端血管移位仅在校正前分析中与靶血管和桥接支架类型的交互作用显著相关(p=0.001)。
  • 靶血管在主动脉起源处的偏差无显著变化。
  • 仅桥接支架外侧曲线长度与靶血管并发症显著相关(p=0.033)。

临床怎么用

  • 中期随访中V12与BeGraft桥接支架对靶血管解剖变化的影响相似。
  • 桥接支架外侧曲线长度可能与靶血管并发症相关,需关注。
  • 主体支架类型影响靶血管解剖,选择时需考虑。

局限性

  • 回顾性单中心研究,样本量有限。
  • 中期随访时间范围较大(2-61个月)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Purpose: To analyze the changes in target vessel (TV) anatomy after fenestrated endovascular aneurysm repair (fEVAR) during midterm follow-up. Materials and Methods: A retrospective single-center study analyzed 56 patients (mean age 71±7 years; 49 men) who underwent fEVAR using custom-made stent-grafts (22 Zenith and 34 Anaconda) between June 2010 and July 2016. Advanta V12 (V12; 74, 53%) and BeGraft (BeG; 66, 47%) stent-grafts were used to bridge to the 140 TVs. Measurements of the TV deviation at the aortic origin, the vessel shift distal to the bridging stent-graft (BSG), and the outer and inner BSG curve lengths were performed after 3-dimensional reconstruction of the serial computed tomography angiography scans. The results of the measurements for the main devices, the TVs, and the bridging stent-grafts were compared using univariable and multivariable analysis. Results: Of the 140 BSGs examined (74 V12s and 66 BeGs), 393 measurements (38 celiac trunks, 102 superior mesenteric arteries, 121 left renal arteries, and 132 right renal arteries) were analyzed. The outer/inner BSG curve length ratio was larger after implantation of Zenith devices compared with Anaconda (p<0.001). The vessel shift distal to the BSG was significantly associated with the interaction of the TV and type of BSG only in the univariable analysis (p=0.001). There were no significant changes of the TV deviation at the aortic origin. Only the outer BSG curve length was significantly associated with TV complications (p=0.033). Median follow-up was 24 months (range 2-61). The BSG curve length ratio showed a significant increase over time (p<0.001) but did not differ between the BeG and V12 (p=0.381). Conclusion: No difference was found between the V12 and the BeG stent-grafts regarding anatomical TV changes during midterm follow-up after fEVAR. Both stent-grafts adapt to the TV anatomy over time, and moderate anatomical changes seem to be tolerated without increasing the risk for TV complications. The type of main device also influences the TV anatomy.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Keschenau PR, Sattler C, Berger T, et al. Changes in Target Vessel Anatomy Following Fenestrated Endovascular Aneurysm Repair: Midterm Results. J Endovasc Ther. 2020. PMID: 32316825. doi:10.1177/1526602820915492

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。