胸主动脉腔内修复术近端锚定区长度遵循推荐与否的结局比较
单中心回顾性研究比较近端锚定区(PLZ)≥2 cm与<2 cm行TEVAR的结局,共63例。遵循组无主要不良事件,非遵循组10例发生12起主要不良事件,包括IA型内漏、移植物移位和逆行夹层,提示PLZ<2 cm与器械相关不良结局相关。
要点
- PLZ<2 cm行TEVAR与IA型内漏、移植物移位和逆行夹层等不良事件相关。
- 遵循组无主要不良事件,非遵循组10例患者发生12起不良事件。
- 急诊TEVAR且PLZ<2 cm者建议严密监测。
核心结论
- 达到推荐的2 cm中心线密封区长度对避免器械相关不良结局至关重要。
- 急诊TEVAR且PLZ<2 cm的患者建议严密监测。
研究设计与样本
- 患者分为PLZ≥2 cm遵循组(18例)和PLZ<2 cm非遵循组(45例),平均年龄53.3±20.6岁。
主要发现
- 非遵循组平均PLZ长度显著短于遵循组(8±7 mm vs 34±15 mm,P < .0001)。
- 两组PLZ位置(zone 1 2例、zone 2 15例、zone 3 46例)和oversizing(遵循组19.4%±8.3%,非遵循组20.3%±10.2%,P = .7)相似。
- 遵循组平均PLZ主动脉直径显著大于非遵循组(29±5 mm vs 25±5 mm,P = .004)。
- 遵循组无主要结局事件,非遵循组10例患者发生12起不良事件(IA型内漏10例、移植物移位1例、逆行夹层1例)。
- 10例IA型内漏中,5例为即刻(4例自愈、1例持续),5例为延迟(1例自愈、1例持续、1例破裂致死、2例需全弓置换)。
临床怎么用
- TEVAR术前应评估PLZ长度,尽量达到推荐的2 cm中心线密封区。
- 对PLZ<2 cm尤其急诊TEVAR患者,应加强术后监测以早期发现IA型内漏等不良事件。
局限性
- 单中心回顾性研究,样本量较小(共63例)。
- 两组随访时间差异较大(遵循组平均126.7天,非遵循组平均233.8天,P = .2)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Success of thoracic endovascular aortic repair (TEVAR) relies heavily on the proximal landing zone (PLZ) sealing. Most instructions for use of thoracic endografts recommend a PLZ length of at least 2 cm. Because of the complex aortic anatomic features, TEVAR landing in zone 1 to zone 3 may not meet this requirement. The aim of this study was to examine whether 2-cm PLZ nonadherence was related to adverse outcomes after TEVAR. METHODS: A retrospective review was performed of patients who underwent zone 1, zone 2, and zone 3 landing TEVAR at a single institution between November 2013 and October 2018. Preoperative and postoperative computed tomography angiography images were analyzed using three-dimensional reconstruction. The patients were categorized into two groups: PLZ ≥2 cm (adherence group) and PLZ <2 cm (nonadherence group). Collected data included patient and anatomic characteristics. Primary outcomes were type IA endoleak, retrograde dissection, and graft migration. RESULTS: The cohort comprised 63 patients (18 in the adherence group and 45 in the nonadherence group) with a mean age of 53.3 ± 20.6 years. Indications for TEVAR were blunt thoracic aortic injury (65.1%), thoracic aneurysm (23.8%), penetrating ulcer (9.5%), and type B dissection (1.6%). Mean PLZ length was significantly shorter for the nonadherence group (8 ± 7 mm for the nonadherence group vs 34 ± 15 mm for the adherence group; P < .0001). PLZ location (2 zone 1, 15 zone 2, 46 zone 3) and oversizing (19.4% ± 8.3% for the adherence group; 20.3% ± 10.2% for the nonadherence group; P = .7) were similar between the groups. The mean PLZ aortic diameter of the adherence group was significantly larger than that of the nonadherence group (29 ± 5 mm for the adherence group; 25 ± 5 mm for the nonadherence group; P = .004). Mean follow-up time was 126.7 days (range, 0-644 days) for the adherence group and 233.8 days (range, 0-1750 days) for the nonadherence group (P = .2). During the study period, no primary outcome was observed in the adherence group, whereas 12 adverse events occurred in 10 patients in the nonadherence group (type IA endoleak, n = 10; graft migration, n = 1; retrograde dissection, n = 1). Of 10 type IA endoleaks, five were immediate (4 resolved spontaneously, 1 remained persistent) and five were delayed (1 resolved spontaneously, 1 remained persistent, 1 ruptured causing death, 2 required total arch replacement). CONCLUSIONS: Achieving recommended sealing zone of 2-cm centerline length is paramount to avoid device-related adverse outcomes. We recommend careful surveillance in patients undergoing urgent TEVAR with <2-cm PLZ.
引用
- Yoon WJ, Mell MW. Outcome comparison of thoracic endovascular aortic repair performed outside versus inside proximal landing zone length recommendation. J Vasc Surg. 2020. PMID: 32289436. doi:10.1016/j.jvs.2020.03.033
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。