烟囱支架在胸主动脉腔内修复中保留左锁骨下动脉
该单中心回顾性研究比较了胸主动脉腔内修复(TEVAR)中保留左锁骨下动脉的两种方法:颈动脉-锁骨下动脉搭桥(CSB,64例)与烟囱支架(CSG,17例),结果显示CSG在围手术期及随访中未出现缺血、闭塞或内漏,结局与CSB相当,提示CSG可作为微创替代方案。
要点
- TEVAR覆盖左锁骨下动脉时,烟囱支架可保留左臂血供,围手术期无缺血或闭塞。
- 烟囱支架组无左半球卒中、无内漏,随访中仅CSB组出现1例闭塞。
- 烟囱支架可作为颈动脉-锁骨下动脉搭桥的微创替代,但样本量小需进一步验证。
核心结论
- 烟囱支架置入以灌注左臂在TEVAR中提供与颈动脉-锁骨下动脉搭桥相当的结果,可作为微创替代方案。
主要发现
- CSB组左半球卒中发生率6%,CSG组为0;CSB组围手术期有1例喉返神经损伤和1例移植物感染。
- 两组住院时间相似(CSB 8.4天 vs CSG 9.1天);围手术期死亡率CSB组2例(3%)vs CSG组0(无统计学差异)。
- 长期随访CT未发现内漏;通畅率相似,仅CSB组在23个月时出现1例闭塞。
关键数值与推荐
- CSG中位随访8个月(范围0-52个月),CSB中位随访14.5个月(范围3-72个月)。
临床怎么用
- 在TEVAR需覆盖左锁骨下动脉时,烟囱支架可作为颈动脉-锁骨下动脉搭桥的微创替代,尤其适用于不宜开放手术者。
局限性
- 回顾性单中心设计,样本量小且分组非随机,CSG组随访时间较短,结论需更大规模研究验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Carotid to subclavian artery bypass (CSB) has been the standard for revascularizing the left subclavian artery during coverage by thoracic endovascular aortic repair (TEVAR). The purpose of this study is to determine if a chimney stent graft (CSG) offers similar outcomes as an alternative to open bypass. METHODS: A retrospective review of a single vascular surgery registry between February 2011 and September 2017 was performed of all left subclavian revascularization during elective TEVAR. Arch reconstructions involving more than just the left subclavian artery were excluded. Indications, demographics, procedural details, and outcomes were analyzed using standard statistical analysis. RESULTS: Eighty-one patients with a mean age of 68 years (range, 32-87 years) had left subclavian revascularization (64 [79%] CSB vs 17 [21%] CSG) during TEVAR. Median follow-up for CSG was 8 months (range, 0-52 months) and for CSB was 14.5 months (range, 3-72). Demographics between the groups were similar except for more males in both groups (43 [67%] in CSB vs 10 [59%] in CSG; P = .28). The CSB group had significantly more aneurysms than dissections compared with CSG (45 [70%] vs 6 [35%]; P = .008). There were no perioperative occlusions or ischemic issues for either group in the perioperative period. Postoperative hematoma rates trended higher in the CSB (7.11% vs 1.6%; P = .53) with three (4.6%) of the CSB requiring evacuation of hematoma. Left hemispheric strokes were 6% in the CSB with none occurring in the CSG group. Perioperatively, the CSB group had one recurrent laryngeal nerve and one graft infection. Length of stay was similar in both groups (CSB, 8.4 days vs CSG, 9.1 days). Perioperative mortality was not statistically significant between both groups with two deaths (3%) in the CSB and none in the CSG group. No gutter leaks were identified on follow-up computed tomography scan during long-term follow-up. Patency rates were similar with only one occlusion in the CSB group at 23 months. CONCLUSIONS: Left common carotid to subclavian artery bypass has been the standard for revascularization of the left subclavian artery during coverage by TEVAR. Chimney stent grafting to perfuse the left arm appears to offer equivalent results as a minimally invasive alternative.
引用
- Ramdon A, Patel R, Hnath J, et al. Chimney stent graft for left subclavian artery preservation during thoracic endograft placement. J Vasc Surg. 2020. PMID: 32089209. doi:10.1016/j.jvs.2019.05.049
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。