文献速递静脉血栓栓塞

重度肥胖与下腔静脉滤器置入时成角相关

Extreme obesity is associated with angulation during inferior vena cava filter placement.
PubMed 文献 · J Vasc Surg Venous Lymphat Disord · 2020-01-09

基于血管质量倡议(VQI)数据库2013年1月至2017年6月7258例下腔静脉滤器置入患者,按体重指数(BMI)分为正常/超重(<30)、肥胖(30-40)和重度肥胖(>40)三组分析围术期结局。多变量分析显示BMI升高与滤器成角相关(P = .03),但与滤器错位(P = .43)及任何并发症或滤器相关死亡(P = .22)无关;仅用透视的亚组分析中,BMI>40者成角风险显著高于BMI<30者(比值比2.12;95%CI 1.07-4.21;P = .03)。

要点

  • 下腔静脉滤器置入总体并发症率低,并发症或滤器相关死亡142例(2.6%)。
  • BMI升高与滤器成角相关,仅透视亚组中BMI>40者成角风险为BMI<30者的2.12倍。
  • 未发现BMI与滤器错位或其他围术期并发症相关的证据。

核心结论

  • 下腔静脉滤器置入并发症率低,BMI升高与滤器成角风险增加相关,但无证据表明BMI与其他围术期并发症相关。

研究设计与样本

  • 基于血管质量倡议(VQI)数据库的回顾性队列研究,纳入2013年1月至2017年6月共7258例下腔静脉滤器置入患者。
  • 按BMI分为正常/超重(<30)、肥胖(30-40)、重度肥胖(>40)三组,分析围术期结局。

主要发现

  • 平均年龄63.6 ± 16.6岁,女性3444例(47%)。
  • BMI<30者4115例(56.7%),30-40者2148例(29.6%),>40者995例(13.7%)。
  • 并发症或滤器相关死亡142例(2.6%);成角1.3%、滤器错位0.5%、穿刺点损伤0.3%、滤器相关死亡0.1%、静脉损伤0.06%。
  • 多变量分析:BMI升高与成角相关(P = .03),与滤器错位(P = .43)、任何并发症或滤器相关死亡(P = .22)无关。
  • 仅透视亚组:BMI>40较BMI<30成角风险显著更高(比值比2.12;95%CI 1.07-4.21;P = .03)。

关键数值与推荐

  • BMI>40者滤器成角风险为BMI<30者的2.12倍(95%CI 1.07-4.21;P = .03,仅透视亚组)。
  • 多变量分析中BMI升高与成角相关P = .03,与滤器错位P = .43、任何并发症或滤器相关死亡P = .22。
  • 并发症或滤器相关死亡总发生率2.6%;成角1.3%、错位0.5%、穿刺点损伤0.3%、滤器相关死亡0.1%、静脉损伤0.06%。

临床怎么用

  • 对重度肥胖(BMI>40)患者置入下腔静脉滤器时应关注滤器成角风险,尤其仅在透视下操作时。
  • BMI升高未显示与滤器错位或其他围术期并发症相关,围术期风险评估可据此权衡。
  • 滤器置入总体并发症率低,可向患者说明操作安全性。

局限性

  • 为回顾性注册数据库分析,可能存在未测量混杂。
  • 仅透视亚组成角风险证据有限,其他结局证据不足。
  • 原文未报告其他局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Placement of inferior vena cava (IVC) filters can be complicated by venous injury, filter misplacement, angulation, insertion site injury, and procedure-related death. Currently, no studies exist evaluating the correlation between obesity and adverse outcomes of IVC filters. We aimed to assess the outcomes of IVC filter placement in the obese population using the Vascular Quality Initiative database. METHODS: The Vascular Quality Initiative registry identified 7258 patients who underwent IVC filter placement from January 2013 to June 2017. Patients were divided into three groups based on their body mass index (BMI): normal/overweight (BMI <30), obese (BMI 30-40), and extremely obese (BMI >40). Periprocedural outcomes were analyzed. RESULTS: The mean age was 63.6 ± 16.6 years and 3444 patients (47%) were female. BMI was less than 30 in 4115 (56.7%), 30 to 40 in 2148 (29.6%), and greater than 40 in 995 (13.7%) patients. A complication or IVC filter-related death occurred in 142 patients (2.6%). Adverse events included angulation (1.3%), IVC filter misplacement (0.5%), insertion site injury (0.3%), IVC filter-related death (0.1%), and venous injury (0.06%). In multivariable analysis, increased BMI was found to be associated with angulation (P = .03), but was not associated with IVC filter misplacement (P = .43), or any complication or IVC filter-related death (P = .22). A subgroup analysis of IVC filter placements using only fluoroscopy demonstrated that the risk of angulation was significantly higher in patients with a BMI of greater than 40 compared with a BMI of less than 30 (odds ratio, 2.12; 95% confidence interval, 1.07-4.21; P = .03). There was not enough evidence to conclude that BMI was associated with any other outcome. CONCLUSIONS: IVC filter insertion has low complication rates. Increased BMI is associated with an increased risk of IVC filter angulation; there is no evidence of association between BMI and other periprocedural complications.

来源:J Vasc Surg Venous Lymphat Disord,查看原文。版权归原作者所有。

引用

  1. Goldman DT, Conway AM, Tran NN, et al. Extreme obesity is associated with angulation during inferior vena cava filter placement. J Vasc Surg Venous Lymphat Disord. 2020. PMID: 31926822. doi:10.1016/j.jvsv.2019.10.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。