颈外动脉狭窄双功能超声新标准:收缩期峰值流速与彩色混叠
本研究前瞻性分析662例患者1324条颈外动脉的双功能超声资料,并以CTA为参照,评估颈外动脉狭窄的诊断标准。结果显示,沿用颈内动脉的PSV≥125 cm/s标准会高估≥50%颈外动脉狭窄的患病率;PSV≥200 cm/s联合彩色混叠对≥50%狭窄具有高敏感度(90%)和高特异度(96%)。
要点
- PSV≥125 cm/s单独用于颈外动脉会高估≥50%狭窄的患病率。
- PSV≥200 cm/s联合彩色混叠诊断≥50%颈外动脉狭窄的敏感度90%、特异度96%。
- 建议将PSV≥200 cm/s加彩色混叠作为颈外动脉≥50%狭窄的超声判断标准。
核心结论
- PSV≥125 cm/s单独评估会高估≥50%颈外动脉狭窄的患病率,PSV≥200 cm/s联合彩色混叠与CTA相关性好,可高度预测>50%颈外动脉狭窄。
研究设计与样本
- 前瞻性研究,纳入2016年12月至2017年7月大学医院血管实验室连续颈动脉双功能超声检查的662例患者共1324条颈外动脉。
主要发现
- 1324条颈外动脉中,174例患者共252条(19%)PSV≥125 cm/s。
- PSV≥125 cm/s的颈外动脉中,30.5%为125–149 cm/s,22.2%为150–174 cm/s,13.1%为175–199 cm/s,34.1%≥200 cm/s。
- 341条颈外动脉分析彩色混叠:PSV≥200 cm/s的86条中58.1%有彩色混叠,PSV<200 cm/s的255条中仅19.2%有彩色混叠(P = .0001)。
- 325例CTA评估显示,PSV≥200 cm/s联合彩色混叠诊断≥50%狭窄的敏感度90%、特异度96%、阳性预测值83%、阴性预测值98%,曲线下面积0.971。
关键数值与推荐
- ECA PSV≥200 cm/s联合彩色混叠为判断≥50% ECA狭窄的最佳标准(敏感度90%、特异度96%)。
- PSV≥125 cm/s单独应用会高估≥50% ECA狭窄的患病率。
临床怎么用
- 临床评估颈外动脉狭窄时,不应直接套用颈内动脉PSV≥125 cm/s标准,应结合PSV≥200 cm/s与彩色混叠综合判断。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The external carotid artery (ECA) serves as a major collateral pathway for ophthalmic and cerebral artery blood supply. It is routinely examined as part of carotid duplex ultrasound, but criteria for determining ECA stenosis are poorly characterized and typically extrapolated from internal carotid artery data. This is despite the fact that the ECA is smaller in diameter, with a higher resistance and lower volume flow pattern. We hypothesized that using the cutoff of a peak systolic velocity (PSV) ≥125 cm/s, extrapolated from internal carotid artery data, will overestimate the prevalence of ≥50% ECA stenosis and aimed to determine a more appropriate criterion. METHODS: From December 2016 to July 2017, consecutive carotid duplex ultrasound studies performed in our university hospital Intersocietal Accreditation Commission-accredited vascular laboratory were prospectively identified and categorized with respect to prevalence and distribution of ECA PSVs and color aliasing, an indication of turbulent flow or flow acceleration. Presence of color aliasing was determined by two individual reviewers and agreement assessed by Cohen κ coefficient. ECA stenosis was calculated by the North American Symptomatic Carotid Endarterectomy Trial (NASCET) method in patients with computed tomography angiography (CTA) performed within 3 months of carotid duplex ultrasound without an intervening intervention. Receiver operating characteristic analysis was performed to identify best criteria for determining ≥50% ECA stenosis. RESULTS: There were 1324 ECAs from 662 patients analyzed; 174 patients had a total of 252 ECAs with PSV ≥125 cm/s (19% of the total sample). Of those ECAs with PSVs ≥125 cm/s, 30.5% were between 125 and 149 cm/s, 22.2% were between 150 and 174 cm/s, 13.1% were between 175 and 199 cm/s, and 34.1% were ≥200 cm/s. There were 341 ECAs that were analyzed for the presence of color aliasing. In 86 ECAs with PSV ≥200 cm/s, 58.1% had color aliasing, whereas in 255 ECAs with PSV <200 cm/s, only 19.2% had color aliasing (P = .0001). There were 325 CTA studies reviewed and assessed for the presence of a ≥50% ECA stenosis as determined by CTA. Overall, the combination of an ECA PSV ≥200 cm/s with the presence of color aliasing provided the highest combination of sensitivity (90%), specificity (96%), positive predictive value (83%), and negative predictive value (98%) and the greatest area under the curve of 0.971 for determining the presence of a ≥50% ECA stenosis based on CTA. CONCLUSIONS: A PSV ≥125 cm/s alone probably overestimates the prevalence of ≥50% ECA stenosis. A PSV ≥200 cm/s combined with color aliasing is highly predictive of >50% ECA stenosis based on correlation with CTA.
引用
- Kronick MD, Chopra A, Swamy S, et al. Peak systolic velocity and color aliasing are important in the development of duplex ultrasound criteria for external carotid artery stenosis. J Vasc Surg. 2020. PMID: 31964570. doi:10.1016/j.jvs.2019.10.099
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。