牛型主动脉弓近端锚定区的几何形态用于TEVAR规划
本研究基于健康主动脉CT分析100例头臂与左颈总动脉共干(CILCA)患者,并与60例标准弓对比。CILCA呈现一致的几何模式:Zone 3严重成角(>60°)且扭曲度大于Zone 2;随弓型从III至I,升主动脉拉长、成角增加,Zone 2缩短且扭曲增加。结论提示该模式对TEVAR规划有参考价值。
要点
- CILCA的Zone 3成角>60°,扭曲度大于Zone 2。
- CILCA整体拉长,Zone 2也较长。
- 弓型III至I时升主动脉成角增加、Zone 2缩短。
核心结论
- CILCA与标准弓相比具有一致且特殊的几何模式,可为TEVAR规划提供信息并可能有预后意义。
研究设计与样本
- 回顾性分析健康主动脉匿名胸部CT,获取100例CILCA,并与60例标准弓健康患者对比。
主要发现
- 100例CILCA患者中男性63%,年龄71.4±7.7岁;1型CILCA 62/100例,2型38/100例,两组年龄可比(p=.11)。
- Zone 3成角>60°(严重),大于Zone 2(p<.001),扭曲度也大于Zone 2(p=.003);该模式在1型和2型CILCA间无差异。
- CILCA的Zone 0扭曲度大于标准弓,与升主动脉拉长相关;CILCA整体拉长,Zone 2也较长。
- 按弓型从III至I,CILCA横段逐渐变平,升主动脉进行性拉长(p=.03)和扭结,Zone 0成角显著增加至严重程度(p=.001)。
- 从III至I,Zone 2长度进行性缩短(p=.004),并与扭曲度增加相关(p<.05);角度测量观察者内和观察者间平均差异分别为1.4°±6.8°(p=.17)和2.0°±10.1°(p=.19)。
临床怎么用
- 在TEVAR术前规划中,应关注CILCA患者Zone 3的严重成角和高扭曲度。
- 对于CILCA且弓型为I型者,需注意升主动脉拉长、成角及Zone 2缩短对锚定区选择的影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The aim was to investigate whether the "bovine" aortic arch (i.e. arch variant with a common origin of the innominate and left carotid artery (CILCA)) is associated with a consistent geometric configuration of proximal landing zones for thoracic endovascular aortic repair (TEVAR). METHODS: Anonymised thoracic computed tomography (CT) scans of healthy aortas were reviewed to retrieve 100 cases of CILCA. Suitable cases were stratified according to type 1 and 2 CILCA, and also based on type of arch (I, II, and III). Further processing allowed calculation of angulation and tortuosity of the proximal landing zones. Centre lumen line lengths of each proximal landing zone were measured in a view perpendicular to the centre line. All geometric features were compared with those measured in healthy patients with a standard arch configuration (n = 60). Two senior authors independently evaluated the CT scans, and intra- and interobserver repeatability were assessed. RESULTS: The 100 selected patients (63% male) were 71.4 ± 7.7 years old. Type 1 CILCA (62/100) was more prevalent than type 2 CILCA (38/100), and the two groups were comparable in age (p = .11). Zone 3 presented a severe angulation (i.e. > 60°), which was greater than in Zone 2 (p < .001), and a consistently greater tortuosity than Zone 2 (p = .003). This pattern did not differ between type 1 and type 2 CILCA. A greater tortuosity was also observed in Zone 0, which was related to increased elongation of the ascending aorta (i.e. Zone 0), than the standard configuration. The CILCA had an overall greater elongation, and Zone 2 also was specifically longer. When stratifying by type of arch, reversely from Type III to Type I, the CILCA presented a gradual flattening of its transverse tract, which entailed a consistent progressive elongation (p = .03) and kinking of the ascending aorta, with a significant increase of Zone 0 angulation to even a severe degree (p = .001). Also, from Type III to Type I, Zone 2 presented a progressively shorter length (p = .004), which was associated with increased tortuosity (p < .05). Mean intra- and interobserver differences for angulation measurements were 1.4° ± 6.8° (p = .17) and 2.0° ± 10.1° (p = .19), respectively. CONCLUSION: CILCA presents a consistent and peculiar geometric pattern compared with standard arch configuration, which provides relevant information for TEVAR planning, and may have prognostic implications.
引用
- Marrocco-Trischitta MM, Alaidroos M, Romarowski RM, et al. Geometric Pattern of Proximal Landing Zones for Thoracic Endovascular Aortic Repair in the Bovine Arch Variant. Eur J Vasc Endovasc Surg. 2019. PMID: 31889656. doi:10.1016/j.ejvs.2019.11.019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。